Novus NVR-6332-H8/FR Instrukcja obsługi

Kategoria
Cyfrowe rejestratory wideo (DVR)
Typ
Instrukcja obsługi
User s ma n ual
(shor t )
NVR-6332-H8/FR
NVR-6332-H8/FR Users manual (Short) ver.1.2
All rights reserved © AAT Systemy Bezpieczeństwa sp. z o.o.
2
IMPORTANT SAFEGUARDS AND WARNINGS
THE PRODUCT MEETS THE REQUIREMENTS CONTAINED IN THE FOLLOWING DIRECTIVES:
Information
The device, as a part of professional CCTV system used for surveillance and control, is not designed for self installation in households by
individuals without technical knowledge. The manufacturer is not responsible for defects and damages resulted from improper or
inconsistent with users manual installation of the device in the system.
ATTENTION!
PRIOR TO UNDERTAKING ANY ACTION THAT IS NOT PROVISIONED FOR THE GIVEN PRODUCT IN ITS USERS MANUAL AND OTHER DOCUMENTS
DELIVERED WITH THE PRODUCT, OR THAT ARISES FROM THE NORMAL APPLICATION OF THE PRODUCT, ITS MANUFACTURER MUST BE CONTACTED
OR THE RESPONSIBILITY OF THE MANUFACTURER FOR THE RESULTS OF SUCH AN ACTION SHELL BE EXCLUDED.
1. Prior to undertaking any action please consult the following manual and read all the safety and operating instructions before starting the device.
2. Please keep this manual for the lifespan of the device in case referring to the contents of this manual is necessary;
3. All the safety precautions referred to in this manual should be strictly followed, as they have a direct influence on users safety and durability and
reliability of the device;
4. All actions conducted by the servicemen and users must be accomplished in accordance with the users manual;
5. The device should be disconnected from power sources during maintenance procedures;
6. Usage of additional devices and components neither provided nor recommended by the producer is forbidden;
7. You are not allowed to use the device in high humidity environment (i.e. close to swimming pools, bath tubs, damp basements);
8. Mounting the device in places where proper ventilation cannot be provided (e. g. closed lockers etc.) is not recommended since it may lead to heat
build-up and damaging the device itself as a consequence;
9. Mounting the device on unstable surface or using not recommended mounts is forbidden. Improperly mounted device may cause a fatal accident or
may be seriously damaged itself. The device must be mounted by qualied personnel with proper authorization, in accordance with this users
manual.
10. Device should be supplied only from a power sources whose parameters are in accordance with those specied by the producer in the devices
technical datasheet. Therefore, it is forbidden to supply the devices from a power sources with unknown parameters, unstable or not meeting
producers requirements;
11. You cannot allow any metal objects get inside the recorder. It might cause serious damage. If a metal object gets inside the device contact the
authorised Novus service immediately.
12. The manufacturer does not bear responsibility for damage or loss of data stored on HDDs or other media occurred during the usage of the product.
Due to the product being constantly enhanced and optimized, certain parameters and functions described in the manual in question may change
without further notice.
We strongly suggest visiting the www.novuscctv.com website in order to access the newest manual .
Technical changes reserved without prior notice and printing errors possible.
DIRECTIVE 2014/30/EU OF THE EUROPEAN PARLIMENT AND OF THE
COUNCIL of 26 February 2014 on the harmonisation of the laws of the Member States
relating to electromagnetic compatibility (OJ L 96, 29.3.2014, p. 79106, with changes)
DIRECTIVE 2014/35/EU OF THE EUROPEAN PARLIAMENT AND OF THE
COUNCIL of 26 February 2014 on the harmonization of the laws of the Member States
relating to the making available on the market of electrical equipment designed for use
within certain voltage limits.
DIRECTIVE 2012/19/EU OF THE EUROPEAN PARLIAMENT AND OF THE
COUNCIL of 4 July 2012 on waste electrical and electronic equipment (WEEE) (OJ L
197, 24.7.2012, p. 3871,with changes)
DIRECTIVE 2011/65/EU OF THE EUROPEAN PARLIAMENT AND OF THE
COUNCIL of 8 June 2011 on the restriction of the use of certain hazardous substances in
electrical and electronic equipment (OJ L 174, 1.7.2011, p. 88110, with changes)
NVR-6332-H8/FR Users manual (Short) ver.1.2
All rights reserved © AAT Systemy Bezpieczeństwa sp. z o.o.
3
FOREWORD INFORMATION
1. FOREWORD INFORMATION
1.1. Network recorders technical data
NVR-6332-H8/FR
Video
IP Cameras up to 32 channels at 3840 x 2160 resolution (video + audio)
Supported Resolution max. 3840 x 2160
Compression H.264, H.264+, H.265
Monitor Output main (split screen, full screen, sequence): 1 x VGA, 1 x HDMI (4K UltraHD)
Dualstreaming Support yes
Fisheye Support yes, 3000/6000 IP series cameras
Audio
Audio Output 1 x line-out (RCA) 1 x HDMI
Recording
Recording Speed 960 fps (32 x 30 fps for 3840 x 2160 and lower)
Stream Size 256 Mb/s in total from all cameras
Recording Mode time-lapse, triggered by: manual, alarm input, motion detection, intelligent image analysis functions
Prealarm/Postalarm up to 5 s/up to 600 s
Display
Display Speed 960 fps (32 x 30 fps)*
Playback
Playback Speed 480 fps (16 x 30 fps for 3840 x 2160) *
Recorded Data Search by date/time, events, motion in a defined area, related to face recognition
Backup
Backup Methods USB port (HDD or Flash memory), network
Backup File Format AVI, RPAS (player included)
Storage
Internal Storage available mount: 8 x HDD 3.5” 14 TB SATA
Total Internal Capacity 112 TB
RAID Mode RAID0, RAID1, RAID5, RAID6
Alarm
Internal Alarm Input/Output 8/4 relay type
Camera Alarm Input/Output supports cameras alarm input/output
Motion Detection supports cameras motion detection
System Reaction to Alarm buzzer, e-mail, alarm output activation, recording activation, PTZ
Intelligent image analysis
Supported Functions Exception, Scene Change, Video Blurred, Video Color Cast, Tripwire, Zone entrance, Abandoned Object, Object Di-
Network
Network Interface 2 x Ethernet - RJ-45 interface, 10/100/1000 Mbit/s
Network Protocols Support HTTP, TCP/IP, IPv4, HTTPS, FTP, DHCP, DNS, DDNS, NTP, RTSP, UPnP, SNMP, SMTP
ONVIF Protocol Support Profile S (ONVIF 2.2 or higher)
PC/MAC Software NMS, Internet Explorer, NVR-6000 Viewer/-
Mobile applications SuperLive Plus (iPhone, Android)
Number of Simultaneous Con-
nections
up to 4 clients
Bandwidth 256 Mb/s in total to all client workstations
PTZ
PTZ Functions pan/tilt/zoom, preset commands
Auxiliary Interfaces
USB Ports 2 x USB 2.0, 1 x USB 3.0
Operating system
Operating System Linux
OSD languages: Polish, English, others
Control PC mouse and IR remote controller (in-set included), network
System Diagnostic automatic control of: HDDs, network, camera connection loss
Security password protection, IP filtering, MAC filtering
Installation parameters
Dimensions (mm) 430 (W) x 90 (H) x 453 (D)
Weight 6 kg (without HDD)
Power Supply 100 ~ 240 VAC
Power Consumption 175 W (with 8 HDDs)
Operating Temperature -10°C ~ 50°C
RACK Mount 19" 2U
NVR-6332-H8/FR Users manual (Short) ver.1.2
All rights reserved © AAT Systemy Bezpieczeństwa sp. z o.o.
4
FOREWORD INFORMATION
1.2. Main characteristics
Supports resolution up to 3840 x 2160
Supported protocols: ONVIF
Recording up to 3840 x 2160
Recorded stream size up to 256 Mb/s in total from all cameras
Mounting up to 8 drives inside - support for RAID0, RAID1, RAID5, RAID6, RADI10
Fishsye camera support
Face detection functions
Internal HDDs mount up to 8
2 x Ethernet - RJ-45, 10/100/1000 Mbit/s
WARNING!
ONVIF protocol support was verified with IP cameras based on ONVIF ver. 2.2 and compatible
with the "PROFILE S".
Implementation of the ONVIF protocol by different manufacturers may vary by some functions,
which can make them work improperly or not in accordance with expectation. AAT SYSTEMY
BEZPIECZEŃSTWA SP. Z O.O. is not responsible for incompatibility problems resulting from
cameras of other brands than NOVUS, which are using ONVIF protocol. If you are using
ONVIF protocol cameras other than NOVUS brand it is recommended to test each time whether
required functions work correctly.
1.3. Package contents
Unpack the device carefully. After unpacking, please ensure that package contains the following items:
Network Video Recorder
USB Mouse
Remote control
Users manual (short)
If any of the elements has been damaged during transport, pack all the elements back into the original
packaging and contact your supplier.
NVR-6332-H8/FR Users manual (Short) ver.1.2
All rights reserved © AAT Systemy Bezpieczeństwa sp. z o.o.
5
STARTING THE DEVICE
2. STARTING THE DEVICE
2.1 Electrical connection and other back panel elements.
NVR-6332-H8/FR
1. LAN1: RJ-45 connector port to connect to the local network and internet.
2. LAN2: RJ-45 connector port to connect to the local network and internet.
3. HDMI2: SPOT monitor connector, use the HDMI cable to connect SPOT monitor
4. USB: USB port for external Flash memory and other USB devices.
5. HDMI: HDMI connector, use the HDMI cable to connect monitor
6. CONNECTORS : Block of alarm input/output connectors
7. AUDIO IN: Audio mono inputs to connect microphones*.
8. FAN : Air outlet of the power supply, do not cover
9. POWER SWITCH: Power switch
10. POWER SOCKET: To plug in the 230 V power cord.
11. E-SATA: Sockets for connecting E-SATA devices
12. AUDIO OUT : Audio output
13. USB 3.0 : USB port for external Flash memory and other USB devices.
14. VGA: VGA connector, to connect VGA monitor
* Will be available in the future.
5
4
1
14
8
9
11
10
2
3
13
6
7
12
NVR-6332-H8/FR Users manual (Short) ver.1.2
All rights reserved © AAT Systemy Bezpieczeństwa sp. z o.o.
6
STARTING THE DEVICE
2.2 HDD mounting
Novus NVR-6332-H8/FR supports up to 8 internal SATA HDDs.
WARNING!
In order to find information regarding the compatible models of HDDs and their maximum
capacities, please contact Novus distributor or check the information presented at
www.novuscctv.com. AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O. is not responsible for
any problems from using not recommended hard drives.
The list of compatible HDDs contains all the HDDs that can be used with a given DVR including
HDDs designed for office use - so called desktop disks. However, due to the fact that reliability of
the recording process and data safety are paramount factors of any CCTV system, we strongly
advise to use HDDs designed for continuous (24/7) operation.
You need to format disks if they were used in a different device. All data saved on HDD prior to
format will be lost.
HDDs Installation
To install the hard disks, unscrew 3 screws on the back of the casing and two on the each side of the
recorder casing (pointed by arrows), sliding top cover backwards and then lifting it up.
WARNING: !
Before removing cover unplug the power cord from the NVR. When NVR is turned on before
disconnecting the power cord, shut down the recorder using the NVR menu.
If you use the disk previously used in another device, it is necessary to format it before using.
Formatting the drive erase all the data from disk. All drives in the recorder should be exactly the
same type.
By default, SATA cables are packed together with DVR accessories, while HDD power cable is
connected to the DVR PSU and ready for connecting the HDD.
After removing the housing, unscrew and remove the upper and lower mounting racks for disks by
unscrewing the screws on the side of the recorder housing.
NVR-6332-H8/FR Users manual (Short) ver.1.2
All rights reserved © AAT Systemy Bezpieczeństwa sp. z o.o.
7
STARTING THE DEVICE
After screwing the disks to the rail it should be remembered that to install posts supporting the top rail.
The bottom rail is supported on two supports with a threaded hole.
When reinstalling the rails with disks, screw the posts supporting the upper rail.
After installing the upper rail, screw the rail to the posts using the screws provided.
Mounted rails with disks should be secured by screwing out screws to the side of the housing.
After connecting disks, please put the top cover onto the DVR and turn the device on in order to check
the operation of particular components and to format the HDDs.
CAUTION!
If the device was brought from a location with lower temperature, please wait until it reaches the
temperature of location it is currently in. Turning the device on immediately after bringing it from a
location with lower ambient temperature is forbidden, as the condensing water vapour may cause short-
circuits and damage the device as a result.
NVR-6332-H8/FR Users manual (Short) ver.1.2
All rights reserved © AAT Systemy Bezpieczeństwa sp. z o.o.
8
STARTING THE DEVICE
2.3 Connecting the HDD to the NVR via the eSATA port
The recorders allow you to connect one external drive via the eSATA port. An external hard drive
connected via the eSATA port, like the internal HDD of the recorder, is used to record recordings.
NOTE: Before connecting or disconnecting the drive to the eSATA port, first turn off the DVR.
2.4. Connecting the power supply.
Please connect provided power cord in the rear power port of the NVR like described below.
To start the unit turn on the power switch on back panel. Initialization lasts approximately 60 seconds.
During this time executing any device functions and pressing any buttons is prohibited. To shut down
the device please use the menu.
CAUTION:
Make connection when the power is not applied and the power switch is turned off.
Do not place the power cord under the carpet or rug. The power cord is usually earth-grounded.
However, even if it's not earth-grounded, never modify it on your own for earth-grounding.
Make sure that power adapter is placed near of NVR and secured from accidental disconnection.
If the device was brought from a location with lower temperature, please wait until it reaches the
temperature of location it is currently in. Turning the device on immediately after bringing it
from a location with lower ambient temperature is forbidden, as the condensing water vapour
may cause short-circuits and damage the device as a result.
Before starting the device familiarize yourself with the description and the role of particular
inputs, outputs and adjusting elements that the device is equipped with.
NVR-6332-H8/FR Users manual (Short) ver.1.2
All rights reserved © AAT Systemy Bezpieczeństwa sp. z o.o.
9
2.5. Connecting monitor
This product supports following interfaces for main monitor: HDMI, VGA.
For HDMI following resolutions are supported: 1280x1024, 1920x1080 i 3840x2160.
2.6. Connecting camera and Network
The NVR-6332-H8/FR has two Ethernet ports for connecting the DVR in two modes. The first mode
in the recorder menu called MULTIPLE ADDRESS SETTINGS allows you to connect NVRs to
networks with different IP addresses. This mode allow to separate network with network cameras
from NVR access network. The second mode, called NETORK FAULT TOLERNANCE allows one
of network sockets of the recorder to be used as an active fault tolerant connection in case if the main
of main connections fails.
The permissible cable distance from the switch to each camera is 100m. Cameras, Internet and other
devices should be connected as shown below.
We recommend that you configure the camera before connecting to a recorder, as described in the
user manual of the camera. Please note that cameras have addressed the unique IP address supported
by the recorder. .
Connecting cameras and network recorder NVR-6332-H8/FR in MULTIPLE ADDRESS
SETTING
STARTING THE DEVICE
NOVUS NVR
INTERNET
PC
COMPUTER
IP CAMERAS
1-32
NETWORK SWITCH ROUTER
NVR-6332-H8/FR Users manual (Short) ver.1.2
All rights reserved © AAT Systemy Bezpieczeństwa sp. z o.o.
10
Connecting NVR-6332-H8/FR and cameras in NETWORK FAULT TOLERNACE mode.
Note: In order to ensure stability and protection against overload and unauthorized access, we
recommend separating the network monitoring of LANs used by users.
Before configuring the connection of the cameras in the recorder, we recommend using a PC to
configure the cameras according to the instructions of the camera.
2.7. Connecting external devices
Connecting audio ports
Audio output signal normally are above 200mV @1kΩ load. You can connect to it the audio amplifier
with the external speakers.
Connecting USB devices
NVR has 1 x USB 2.0 port on front and one 1 x USB 2.0 and 1 x 3.0 USB port on back panel . They
could be used for connecting external Flash memory, mouse connection and other USB compatible
devices. To connect storage memory it is recommended to use port USB 3.0
STARTING THE DEVICE
NOVUS NVR
INTERNET
PC
COMPUTER
IP CAMERAS 1-32
NETWORK SWITCH
ROUTER
BACKUP CONNECTIONS
NVR-6332-H8/FR Users manual (Short) ver.1.2
All rights reserved © AAT Systemy Bezpieczeństwa sp. z o.o.
11
Connecting alarms ports
Example of connecting alarm output no. 1, follow the drawing below:
Example of sensor connection to alarm input 1.
STARTING THE DEVICE
NO COM
ALARM
Power
source
NO1 COM1
ALARM
Power
source
GND
Alarm in
Alarm out
RS485
NVR-6332-H8/FR Users manual (Short) ver.1.2
All rights reserved © AAT Systemy Bezpieczeństwa sp. z o.o.
12
NVR OPERATING
3. NVR OPERATING
3.1. Front panel description
1. LED LEDs for monitoring NVR activity.
- REC - monitors recording activity
- NET - monitors networking activity
- PWR - activities when power is on
2. USB PORT USB 2.0 port for external Flash memory and mouse connection.
.
3.2. Controlling via USB mouse
It is possible to control NVR via an USB mouse connected to the USB port. Double-click on any
camera in split screen display mode switches the display to full-screen mode. Subsequent double-click
returns to previous display mode. Move cursor to the top or click the right key of mouse to bring up
MAIN MENU and select START icon.
Certain positions allow to select them via mouse scroll. Depending on NVR operating mode, pressing
RMB displays a corresponding function menu.
3.3. System menu operations
To start NVR plug power cable and switch on power. The power led turns on. After booting, the video
output default is multi-window output mode.
Note:
If the currently selected NVR menu language is not as expected, to change it, please follow the
procedure described in chapter 4.3 of this manual.
1
2
NVR-6332-H8/FR Users manual (Short) ver.1.2
All rights reserved © AAT Systemy Bezpieczeństwa sp. z o.o.
13
To unlock the DVR menu, click the button at the bottom left of the screen.
After clicking on button click-on LOGIN
Then login in entering password in PASSWORD field (default password for user root is pass)
and then click-in LOGIN button
NVR OPERATING
NVR-6332-H8/FR Users manual (Short) ver.1.2
All rights reserved © AAT Systemy Bezpieczeństwa sp. z o.o.
14
3.4. Startup configuration
Prior to using NVR for the first time, initial setup is strongly advised. Before you connect the IP
cameras to the NVR, please set up network and stream parameters of IP cameras in the right way.
Note:
For suggested values for IP camera setting please refer to the Cameras Capability Tableavailable
on the www.novuscctv.com website. If you set wrong values some problems may appear: the NVR
cannot search the IP camera, the stream cannot be connected, the image is not fluent, the image quality
is bad and so on.
In case of first NVR start WIZARD SETUP menu window will occur (if function wasnt disabled
earlier). To configure NVR please follow procedure like below, after finishing all the steps youll be
ready to work:
Provide username and password and click on NEXT button so start wizard.
NVR OPERATING
NVR-6332-H8/FR Users manual (Short) ver.1.2
All rights reserved © AAT Systemy Bezpieczeństwa sp. z o.o.
15
I. NETWORK SETTINGS : This menu allows to set up networking. To select desired mode clik-on
WORK PATTERN field. MULTIPLE ADDRESS SETTING mode allows to use address Ethernet
Interfaces in separated IP subnets. NETWORK FAULT TOLERANCE uses one of Ethernet interface
as an fault tolerant connection activated after main connection break down. Default IP configuration is
192.168.1.100 netmask 255.255.255.0. It is possible to configure IP address for switch in INTERNAL
ETHERNET PORT SECTION. Please note that IP subnet for the ETHERNET PORT 1 and
INTERNAL ETHERNET PORT were different. In cases where it is necessary to connect NVR to the
Internet (for remote access, email sending, etc.), configure the following parameters: Gateway,
Primary and Secondary DNS. You can also enable DHCP mode which allows you to download an IP
address from a DHCP server (required if running a DHCP server). It is possible to change the default
HTTP port designed to display Web panel of the device and RTSP ports and port server data. After
changing parameter pres NEXT button.
NVR OPERATING
Internal PoE Ports
IP address settings
Internal PoE Ports
IP address settings
Work pattern selction
NVR-6332-H8/FR Users manual (Short) ver.1.2
All rights reserved © AAT Systemy Bezpieczeństwa sp. z o.o.
16
II. QR CODES : This menu allows you to scan a QRcode in the Supelive plus application or enter a
device code to autonat.com site. The service allows you to connect to a device connected to the Internet
network behind a router equipped with NAT.
NOTE: SYSTEMY BEZPIECZEŃSTWA SP. Z O.O. is not responsible for the operation of the service
autonat.com which is provided by third parties.
III. Add Camera: Allows you to configure the camera and add them to the recorder. Upper window
displays cameras discovered by the NVR. To change the addressable cameras, click on the icon in
the column EDIT (This works with cameras NOVUS IP 3000 series).
NVR OPERATING
NVR-6332-H8/FR Users manual (Short) ver.1.2
All rights reserved © AAT Systemy Bezpieczeństwa sp. z o.o.
17
Enter the address in the IP ADDRESS field and set the masks in the SUBNET MASK, then press the
OK button to save the settings.
Press the button to add a camera to the system.
Added camera will be displayed on the bottom of the menu list. To edit the connection settings of the
camera, press the EDIT column.
If you are having problems connecting to the camera, you must enter the correct user name in the
USER NAME and password in the PASSWORD field and then press the OK button to save the
settings. If the NVR connected to the camera in STATUS filed will be displayed Connected”. To
remove a camera from the list, press the in DELETE column.
NVR OPERATING
NVR-6332-H8/FR Users manual (Short) ver.1.2
All rights reserved © AAT Systemy Bezpieczeństwa sp. z o.o.
18
IV.DISK SETTINGS : In this tab information about the hard disk detected by the DVR is displayed.
Before starting work, you need to format the hard disk by selecting it in the list of drives and then
pressing FORMAT.
Formatting may take a few moments. After properly formatted STATUS field should have a value of
RW(Read/Write).
V. Record Settings :
You can set one of the modes:
- MANUAL RECORD SETTINGS - You can set the recording time from the moment you select the
manual recording in range from 1 minute to 1 hour or manually off recording.
NVR OPERATING
NVR-6332-H8/FR Users manual (Short) ver.1.2
All rights reserved © AAT Systemy Bezpieczeństwa sp. z o.o.
19
AUTO - set all the cameras on one of the following modes :
- MOTION RECORD - starts recording after receiving motion detection information from the camera.
- SENSOR RECORD - starts recording after alarm generated on alarm input
- MOTION RECORD + SENSOR RECORD - starts recording after motion detecion alarm and after
alarm from alarm inputs
- ALWAYS(24x7) RECORD + MOTION RECORD - continuous recording and recording after
receiving motion detection information from the camera.
- ALWAYS(24x7) RECORD + SENSOR RECORD - continuous recording and recording alarm
generated on alarm input
- ALWAYS(24x7) RECORD + MOTION RECORD + SENSOR RECORD - continuous recording
and recording alarm generated on alarm input and after receiving motion detection information from
the camera.
- ALWAYS(24x7) RECORD + MOTION RECORD + SENSOR RECORD + INTELIGENCE
RECORD - continuous recording and recording alarm generated on alarm input, motion detection
information and after receiving Intelligence Analysis from the camera.
NVR OPERATING
NVR-6332-H8/FR Users manual (Short) ver.1.2
All rights reserved © AAT Systemy Bezpieczeństwa sp. z o.o.
20
4. NVR MENU
4.1. Live monitoring
NOVUS network video recorders features a multilingual OSD menu allowing to adjust the settings of
the device. Available languages are: English, Polish, and others
As soon as the NVR completes its initialization process, it will enter the real-time monitoring image.
Displaying all cameras simultaneously is the default mode. On the bottom of screen STATUS BAR is
displayed.
To start access to the NVR click on the button to launch the start menu.
After clicking log on to the system (the default password for the root user is a pass).
STATUS BAR description:
NVR MENU
MENU BAR
VIDEO WINDOW
VIEW MENU
START MENU
Item Icon Description
Search Launches search for recordings
Playback
Starts playback menu
Backup
Starts backup menu
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78

Novus NVR-6332-H8/FR Instrukcja obsługi

Kategoria
Cyfrowe rejestratory wideo (DVR)
Typ
Instrukcja obsługi