CAUTIONS AND WARNINGS
THE PRODUCT MEETS THE REQUIREMENTS CONTAINED IN THE FOLLOWING DIRECTIVES:
Exclusion of liability in the event of damage to data contained on disks or other devices or media:
The manufacturer is not liable in the event of damage or loss of data contained on disks or other
devices or carriers during the operation of the Product.
Obligation to consult the Manufacturer before performing any action not provided for in the
instruction manual or other documents:
Before performing an action that is not provided for a given Product in the user manual, other
documents attached to the Product or does not result from the normal purpose of the Product, it is
necessary, under pain of exclusion of the Manufacturer's liability for the consequences of such action,
to contact the Manufacturer.
Pictures in this publication showing camera views can be simulations. Actual camera
images may vary depending on the type, model, settings, observation area, or
environmental conditions.
DIRECTIVE 2014/30/EU OF THE EUROPEAN PARLIMENT AND OF THE
COUNCIL of 26 February 2014 on the harmonization of the laws of the Member States
relating to electromagnetic compatibility (OJ L 96, 29.3.2014, p. 79106, with changes).
DIRECTIVE 2012/19/EU OF THE EUROPEAN PARLIAMENT AND OF THE
COUNCIL of 4 July 2012 on waste electrical and electronic equipment WEEE)
(OJ L 197, 24.7.2012, p. 3871, with changes).
DIRECTIVE 2011/65/EU OF THE EUROPEAN PARLIAMENT AND OF THE
COUNCIL of 8 June 2011 on the restriction of the use of certain hazardous substances in
electrical and electronic equipment (OJ L 174, 1.7.2011, p. 88110, with changes).
COMMISION DELEGATED DIRECTIVE (EU) 2015/863 of 31 March 2015 amending
Annex II to Directive 2011/65/EU of the European Parliament and of the Council as regards
the list of restricted substances.
DIRECTIVE (EU) 2017/2102 OF THE EUROPEAN PARLIAMENT AND OF THE
COUNCIL of 15 November 2017 amending Directive 2011/65/EU on the restriction of the
use of certain hazardous substances in electrical and electronic equipment.
DIRECTIVE 2014/35/EU OF THE EUROPEAN PARLIAMENT
AND OF THE COUNCIL of 26 February 2014 on the harmonisation
of the laws of the Member States relating to the making available on the
market of electrical equipment designed for use within certain voltage limits.
NVR-6332-H8/FR-II Quick start guide version 1.1
All rights reserved © AAT Systemy Bezpieczeństwa sp. z o.o.
3
SAFETY REQUIREMENTS
1. Please read this manual carefully before installation and operation;
2. Please keep this manual for the lifespan of the device in case referring to the contents of this
manual is necessary;
3. It is necessary to comply with the safety requirements described in the manual, as they have a
direct impact on the safety of users and the durability and reliability of the device;
4. All activities performed by installers and users must be carried out as described in the manual;
5. The device should be disconnected from power sources during maintenance procedures;
6. It is not allowed to use any additional devices, components or accessories not provided for and not
recommended by the manufacturer;
7. Do not install this device in places where proper ventilation cannot be provided (e.g. closed
cabinets, etc.), as this may cause heat build-up and may result in damage;
8. Do not place the device on unstable surfaces. Installation must be carried out by qualified
personnel with appropriate permissions in accordance with the recommendations provided in this
manual;
9. The device may be powered only from sources with parameters compliant with those indicated by
the manufacturer in the technical data;
Before using the device, read the instruction manual in order to ensure proper and safe operation
of the device. Failure to comply with the instructions may lead to damage to the device and/or
safety violations.
The user may not repair the device himself. Repairs and maintenance of the device may only be
performed by qualified service personnel.
The device, which is an element of a professional CCTV system used for supervision and
control, is not intended for self-assembly in households by persons without specialist
knowledge.
As the product is constantly improved and optimised, some of its parameters and functions may have
changed from those described in this manual. If in doubt, please refer to the user manual at
www.novuscctv.com
The user manual located at www.novuscctv.com is always the most up-to-date version.
NVR-6332-H8/FR-II Quick start guide version 1.1
All rights reserved © AAT Systemy Bezpieczeństwa sp. z o.o.
4
FOREWORD INFORMATION
1. FOREWORD INFORMATION
1.1. Main characteristics
Network Video Recorder for 32 IP cameras.
2 x Gigabit Ethernet port.
Recording resolution up to 4000x3000.
H.264, H.265, H.265+, H.265 Smart compression.
Recording stream up to 160 Mb/s in total from all cameras.
ONVIF protocol support.
Dual stream recording
Support 8 x SATA 3,5” HDDs. *
RAID0, RAID1, RAID5, RAID6, RADI10.
Operating system based on Linux.
Main monitor 1 x HDMI (4K UltraHD), 1 x VGA (FullHD), spot monitor 1 x HDMI (FullHD).
Exception, Scene Change, Video Blurred, Video Color Cast, Tripwire, Zone entrance, Abandoned
Object, Object Disappearance, Face Recognition, Perimeter Intrusion Detection by pedestrian or
vehicle, Line Cross Detection by pedestrian or vehicle, Analysis of Recognized Number Plate
Numbers (LPR) **
Backup: onto HDD or USB Flash Memory through USB port and through the IP network.
Software: N Control 6000 (application for remote administration, live monitoring and recorded data
search).
SuperLive Plus application for live and playback functions from mobile devices.
User friendly multi-lingual OSD.
IR remote controller and PC mouse included
RACK mounts
* List of compatible HDD models and maximum capacities is available on the product website
www.novuscctv.pl in the DOWNLOADABLE FILES tab in the "HDD Compatible disks" file.
** Functions depend on connected camera model.
NVR-6332-H8/FR-II Quick start guide version 1.1
All rights reserved © AAT Systemy Bezpieczeństwa sp. z o.o.
5
1.2. Recorderstechnical data
*** With dualstream mode.
NVR-6332-H8/FR-II
Video
IP Cameras up to 32 channels at 4000 x 3000 resolution (video + audio)
Maximum Supported
Camera Resolution max. 4000 x 3000
Compression H.264, H.265, H.265+, H.265 Smart
Monitor Output main (split screen, full screen, sequence): 1 x VGA, 1 x HDMI (4K UltraHD)
spot: 1 x HDMI (FullHD)
Dualstreaming Support yes
Fisheye Support yes, 6000 IP series cameras
using Internet Explorer, SuperLive Plus, N Control 6000
Audio
Audio Input/Output 1 x line-in (RCA) / 1 x HDMI, 1 x line-out (RCA)
Recording
Recording Speed 960 fps (32 x 30 fps for 4000 x 3000 and lower)
Stream Size 160 Mb/s in total from all cameras
Recording Mode continuous, triggered by: manual, alarm input, motion detection, face recognition, intel-
ligent image analysis functions
Prealarm/Postalarm up to 5 s/up to 600 s
Display
Display Speed 960 fps (32 x 30 fps) ***
Playback
Playback Speed 480 fps (16 x 30 fps) ***
Recorded Data Search by date/time, events, image analysis events, POS, motion in a defined area, related to
face recognition, tags, licence plate number
Backup
Backup Methods USB port (HDD or Flash memory), network
Backup File Format MP4, AVI, RPAS (player included)
Storage
Internal Storage available mount: 8 x HDD 3.5” 10 TB SATA
Total Internal Capacity 80 TB
RAID Mode RAID0, RAID1, RAID5, RAID6, RAID10
Alarm
Internal Alarm Input/
Output 16/4 relay type
Camera Alarm Input/
Output supports IP cameras alarm input/output
Motion Detection supports cameras motion detection
System Reaction to
Alarm Events
buzzer, alarm output activation, recording activation, PTZ, e-mail with atatchment, Full
Screen, PUSH message, voice prompt, snapshot
Intelligent image analysis
Supported Functions
Exception, Scene Change, Video Blurred, Video Color Cast, Tripwire, Zone entrance,
Abandoned Object, Object Disappearance, Face Recognition, Perimeter Intrusion De-
tection by pedestrian or vehicle, Line Cross Detection by pedestrian or vehicle, Analy-
sis of Recognized Number Plate Numbers (LPR)
Database Capacity 10000 faces
50000 license plates
Other parameters face recognition for 6 NOVUS 6000 series IP cameras with "F" in the model name or 2
ONVIF cameras
FOREWORD INFORMATION
NVR-6332-H8/FR-II Quick start guide version 1.1
All rights reserved © AAT Systemy Bezpieczeństwa sp. z o.o.
6
FOREWORD INFORMATION
The availability of individual functions (including image analysis) depends on the model of the
cameras used, as well as the software version of the recorder and cameras.
In order to create face recognition system, please deploy NOVUS 6000 series IP cameras with "F" in
the model name.
Presented display and playback speeds are achieved using dual-streaming. Detailed data on hard drives
can be found at www.novuscctv.com in the compatibility table available in the DOWNLOADABLE
FILES tab.
1.3. Package contents
Unpack the device carefully. After unpacking, please ensure that package contains the following items:
Network Video Recorder
USB Mouse
Remote control
Power cable
Quick start guide
Rack mounts
If any of the elements has been damaged during transport, pack all the elements back into the original
packaging and contact your supplier.
NVR-6332-H8/FR-II
Network
Network Interface 2 x Ethernet - RJ-45 interface, 10/100/1000 Mbit/s
Network Protocols
Support
HTTP, TCP/IP, IPv4/v6, HTTPS, FTP, DHCP, DNS, DDNS, NTP, RTSP, UPnP, SNMP,
IEEE 802.1X, PPPoE, SMTP, P2P, POS, HTML5
ONVIF Protocol
Support Profile S (ONVIF 2.2 or higher)
PC/MAC Software NMS, Internet Explorer, Firefox, Chrome, Opera, N Control 6000, Edge/Safari, N Con-
trol 6000
Mobile applications SuperLive Plus (iPhone, Android)
Number of Simulta-
neous Connections up to 10 clients, up to 36 main streams or 128 substreams or 16 playback streams in total
Bandwidth 160 Mb/s in total to all client workstations
PTZ
PTZ Functions pan/tilt/zoom, preset commands
Auxiliary Interfaces
USB Ports 2 x USB 2.0, 1 x USB 3.0
Operating system
Operating System Linux
OSD languages: Polish, English, others
Control PC mouse and IR remote controller (in-set included), network
System Diagnostic automatic control of: HDDs, network, camera connection loss
Security password protection, IP filtering, MAC filtering
Installation parameters
Dimensions (mm) 430 (W) x 90 (H) x 453 (D)
Weight 6 kg (without HDD)
Power Supply 100 ~ 240 VAC
Power Consumption 175 W (with 8 HDDs)
Operating Temperatu-
re -10°C ~ 50°C
RACK Mount 19" 2U
NVR-6332-H8/FR-II Quick start guide version 1.1
All rights reserved © AAT Systemy Bezpieczeństwa sp. z o.o.
7
STARTING THE DEVICE
NOTE!
ONVIF protocol support was verified with IP cameras based on ONVIF ver. 2.2 and compatible
with the "PROFILE S".
Implementation of the ONVIF protocol by different manufacturers may vary by some functions,
which can make them work improperly or not in accordance with expectation. AAT SYSTEMY
BEZPIECZEŃSTWA SP. Z O.O. is not responsible for incompatibility problems resulting from
cameras of other brands than NOVUS, which are using ONVIF protocol. If you are using
ONVIF protocol cameras other than NOVUS brand it is recommended to test each time whether
required functions work correctly.
2. STARTING THE DEVICE
2.1 Electrical connection and other back panel elements.
NVR-6332-H8/FR-II
1. LAN1: RJ-45 connector port to connect to the local network and Internet.
2. LAN2: RJ-45 connector port to connect to the local network and Internet.
3. HDMI2: SPOT monitor connector, use the HDMI cable to connect SPOT monitor
4. HDMI: HDMI connector, use the HDMI cable to connect monitor
5. USB 3.0 : USB 3.0 port for external Flash memory and other USB devices.
6. USB 2.0: USB 2.0 port for external Flash memory and other USB devices.
7. CONNECTORS : Block of alarm input/output connectors
8. AUDIO IN: Audio mono input to connect microphone
9. FAN : Air outlet of the power supply, do not cover
10. POWER SWITCH: Power switch
11. POWER SOCKET: To plug in the 230 V power cord.
12. AUDIO OUT : Audio output
13. E-SATA: Socket for connecting E-SATA device
14. VGA: D-SUB connector, to connect VGA monitor
6
4
14
9
10
11
2
3
13
7
8
12
1
5
NVR-6332-H8/FR-II Quick start guide version 1.1
All rights reserved © AAT Systemy Bezpieczeństwa sp. z o.o.
8
STARTING THE DEVICE
2.2 HDD mounting
Novus NVR-6332-H8/FR-II supports up to 8 internal SATA HDDs.
NOTE!
In order to find information regarding the compatible models of HDDs and their maximum
capacities, please contact Novus distributor or check the information presented at
www.novuscctv.com. AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O. is not responsible for
any problems from using not recommended hard drives.
The list of compatible HDDs contains all the HDDs that can be used with a given NVR including
HDDs designed for office use - so called desktop disks. However, due to the fact that reliability of
the recording process and data safety are paramount factors of any CCTV system, we strongly
advise to use HDDs designed for continuous (24/7) operation.
You need to format disks if they were used in a different device. All data saved on HDD prior to
format will be lost.
HDDs Installation
To install the hard disks, unscrew 2 screws on the back of the case, slide the top cover back and then
lift it up.
NOTE!
Before removing top cover unplug the power cord from the NVR. When NVR is turned on before
disconnecting the power cord, shut down the recorder using the NVR menu.
If you use the disk previously used in another device, it is necessary to format it before using.
Formatting the drive erase all the data from disk. All drives in the recorder should be exactly the
same type.
By default, SATA cables are packed together with NVR accessories, while HDD power cable is
connected to the NVR PSU and ready for connecting the HDD.
After removing the housing, unscrew and remove the upper and lower mounting racks for disks by
unscrewing the screws on the side of the recorder housing.
NVR-6332-H8/FR-II Quick start guide version 1.1
All rights reserved © AAT Systemy Bezpieczeństwa sp. z o.o.
9
STARTING THE DEVICE
After screwing the disks to the rail it should be remembered that to install posts supporting the top rail.
The bottom rail is supported on two supports with a threaded hole.
When reinstalling the rails with disks, screw the posts supporting the upper rail.
After installing the upper rail, screw the rail to the posts using the screws provided.
Mounted rails with disks should be secured by screwing out screws to the side of the housing.
After connecting disks, please put the top cover onto the NVR and turn the device on in order to check
the operation of particular components and format the HDDs.
NOTE!
If the device was brought from a location with lower temperature, please wait until it reaches the
temperature of location it is currently in. Turning the device on immediately after bringing it
from a location with lower ambient temperature is forbidden, as the condensing water vapour
may cause short-circuits and damage the device as a result.
NVR-6332-H8/FR-II Quick start guide version 1.1
All rights reserved © AAT Systemy Bezpieczeństwa sp. z o.o.
10
STARTING THE DEVICE
2.3 Connecting the HDD to the NVR via the eSATA port
The recorders allow you to connect one external drive via the eSATA port. An external hard drive
connected via the eSATA port, like the internal HDD of the recorder, is used to record recordings.
NOTE: Before connecting or disconnecting the drive to the eSATA port, turn off the NVR.
2.4. Connecting the power supply.
Please connect provided power cord in the rear power port of the NVR like described below.
To start the unit turn on the power switch on back panel. Initialization lasts approximately 120 seconds.
During this time executing any device functions and pressing any buttons is prohibited. To shut down
the device please use the menu.
NOTE:
Make connection when the power is not applied and the power switch is turned off.
Do not place the power cord under the carpet or rug. The power cord is usually earth-grounded.
However, even if it's not earth-grounded, never modify it on your own for earth-grounding.
Make sure that power adapter is placed near of NVR and secured from accidental disconnection.
If the device was brought from a location with lower temperature, please wait until it reaches the
temperature of location it is currently in. Turning the device on immediately after bringing it
from a location with lower ambient temperature is forbidden, as the condensing water vapour
may cause short-circuits and damage the device as a result.
Before starting the device familiarize yourself with the description and the role of particular
inputs, outputs and adjusting elements that the device is equipped with.
NVR-6332-H8/FR-II Quick start guide version 1.1
All rights reserved © AAT Systemy Bezpieczeństwa sp. z o.o.
11
2.5. Connecting monitor
This product supports following interfaces for main monitor: HDMI, VGA.
For HDMI following resolutions are supported: 1024x768, 1280x1024, 1920x1080 and 3840x2160.
2.6. Connecting camera and Network
The NVR-6332-H8/FR-II has two Ethernet ports for connecting the NVR in two modes. The first
mode in the recorder menu called MULTIPLE ADDRESS SETTING allows to connect NVR to
networks with different IP addresses. This mode allows to separate cameras network and NVR access
network. The second mode, called NETWORK FAULT TOLERNACE allows one of network
sockets of the recorder to be used as an active fault tolerant connection in case of the main connection
fails.
The permissible cable distance from the switch to each camera is 100m. Cameras, Internet and other
devices should be connected as shown below.
We recommend that you configure the camera before connecting to a recorder, as described in the
user manual of the camera. Please note that cameras have addressed the unique IP address supported
by the recorder. .
Connecting cameras and network recorder NVR-6332-H8/FR-II in MULTIPLE ADDRESS
SETTING
STARTING THE DEVICE
NOVUS NVR
INTERNET
PC
COMPUTER
IP CAMERAS
1-32
NETWORK SWITCH ROUTER
NVR-6332-H8/FR-II Quick start guide version 1.1
All rights reserved © AAT Systemy Bezpieczeństwa sp. z o.o.
12
Connecting NVR-6332-H8/FR-II and cameras in NETWORK FAULT TOLERNACE mode.
Note: In order to ensure stability and protection against overload and unauthorized access, we
recommend separating the network monitoring of LANs used by users.
Before configuring the connection of the cameras in the recorder, we recommend using a PC to
configure the cameras according to the instructions of the camera.
2.7. Connecting external devices
Connecting audio ports
Audio output signal normally are above 200mV @1kΩ load. You can connect to it the audio amplifier
with the external speakers.
Connecting USB devices
NVR has 1 x USB 2.0 port on front and one 1 x USB 2.0 and 1 x 3.0 USB port on back panel . They
could be used for connecting external Flash memory, mouse connection and other USB compatible
devices. To connect storage memory it is recommended to use port USB 3.0.
STARTING THE DEVICE
NOVUS NVR
INTERNET PC
COMPUTER
IP CAMERAS 1-32
NETWORK SWITCH
ROUTER
BACKUP CONNECTION
NVR-6332-H8/FR-II Quick start guide version 1.1
All rights reserved © AAT Systemy Bezpieczeństwa sp. z o.o.
13
Connecting alarms ports
Example of connecting alarm output no. 1, follow the drawing below:
Example of sensor connection to alarm input 1.
STARTING THE DEVICE
NO1 COM1 ALARM
Power
source
GND
Alarm inputs
Alarm outputs
RS485
ALARM
SENSOR
NVR-6332-H8/FR-II Quick start guide version 1.1
All rights reserved © AAT Systemy Bezpieczeństwa sp. z o.o.
14
2.7. Security recommendations for network architecture and configuration
NOTE!
Below are shown security recommendations for network architecture and configuration
of CCTV systems that are connected to the Internet to reduce the risk
of unauthorized interference with the system by a third party.
1. Absolutely change the default passwords and user names (if the device gives this possibility)
of all applied network devices (recorders, cameras, routers, network switches,
etc.) to the severely complexity password. Use lowercase and uppercase letters, numbers, and special
characters if there is such possibility.
2. Depending on the available functionality in the order to restrict access to the used network devices
at the administrator account level, it is recommended to configure the users accounts accordingly.
3. Do not use DMZ function (Demilitarized zone) in your router. Using that function you open
the access to recorder system from the Internet on all ports, which gives possibility for
an unauthorized interference with the system.
Instead of DMZ use port forwarding redirect only the ports which are necessary for the performance
of the connection (detailed information about ports of communication in different models of recorders,
cameras, etc. can be found in the operating instructions).
4. Use routers with firewall function and make sure it is enabled and properly configured.
5. It is recommended to change the default network communication port numbers of used devices
if there is such possibility.
6. If used network devices has a UPnP feature and it is not used, turn it off.
7. If used network devices has a P2P feature and it is not used, turn it off.
8. If used network devices support HTTPS protocol for connection, it is recommended to use it.
9. If used network devices support IP filtering for authorized connections function, it is recommended
to use it.
10. If used recorder has two network interfaces it is recommended to use both of them to physically
separate network for cameras and network for Internet connection. The only device in the system,
accessible from Internet is recorder - there is no physically access directly to any camera.
STARTING THE DEVICE
NVR-6332-H8/FR-II Quick start guide version 1.1
All rights reserved © AAT Systemy Bezpieczeństwa sp. z o.o.
15
NVR OPERATING
3. NVR OPERATING
3.1. Front panel description
1. LED LEDs for monitoring NVR activity.
- REC - monitors recording activity
- NET - monitors networking activity
- PWR - activities when power is on
2. USB PORT USB 2.0 port for external Flash memory and mouse connection.
.
3.2. Controlling via USB mouse
It is possible to control NVR via an USB mouse connected to the USB port. Double-click on any
camera in split screen display mode switches the display to full-screen mode. Subsequent double-click
returns to previous display mode. Move cursor to the top or click the right key of mouse to bring up
MAIN MENU and select START icon.
Certain positions allow to select them via mouse scroll. Depending on NVR operating mode, pressing
RMB displays a corresponding function menu.
3.3. First Launch Wizzard
In order to start the device, connect the power cable to the power supply, turn on the switch located on
the back of the housing and wait for the recorder menu to start.
After the NVR first launch, a window is displayed that allows to select the language and location. To
select the English language, select ENGLISH in the left-hand window and select the recorder location
in the right-hand window.
1
2
NVR-6332-H8/FR-II Quick start guide version 1.1
All rights reserved © AAT Systemy Bezpieczeństwa sp. z o.o.
16
NVR OPERATING
In the next step, read and accept the Privacy Statement. Check the checkbox at the bottom of the
window and press OK.
NVR-6332-H8/FR-II Quick start guide version 1.1
All rights reserved © AAT Systemy Bezpieczeństwa sp. z o.o.
17
NVR OPERATING
The next wizard window allows to set time parameters such as TIME ZONE, SYSTEM TIME, DATE
FORMAT, TIME FORMAT, DST, SYNCHRONOUS, NTP SERVER and VIDEO FORMAT. After
making your selection, click the NEXT button.
Change the password in the password change wizard. The password must be at least 8 characters long.
It should contain a number, and upper and lower case letters. Enter them on the screen keyboard
available after clicking in the NEW PASSWORD and CONFIRM PASSWORD fields.
NVR-6332-H8/FR-II Quick start guide version 1.1
All rights reserved © AAT Systemy Bezpieczeństwa sp. z o.o.
18
NVR OPERATING
To display the entered password, check the DISPLAY PASSWORD box. Selecting LOG IN
AUTOMATICALLY checkbox will automatically log the user into the system after starting the
recorder.
By selecting the ENABLE field in the PATTERN LOCK row, it is possible to activate the setting of
enabling access for the user by means of a graphic pattern instead of entering the password. To start
the graphic symbol settings, click the EDIT button. Then, holding down the left mouse button, move
the cursor between the displayed circles twice to mark the pattern that will be used to unlock the
device.
After clicking on the NEXT button, a window is displayed that allows you to set a set of questions and
answers that can unlock access to the recorder.
NVR-6332-H8/FR-II Quick start guide version 1.1
All rights reserved © AAT Systemy Bezpieczeństwa sp. z o.o.
19
NVR OPERATING
To add a question, click on the QUESTION field to enter the question using the keyboard. Then click
on the ANSWER field to enter the answer to the question. Clicking on the ADD button adds a set of
questions and answers. Clicking the NEXT button takes you to the window in which information about
the disk connected to the recorder is displayed.
If the STATUS field displays information about the inaccessibility of the disk, format the disk by
clicking on the FORMAT button. A window appears asking to confirm that you want to format the
disk.
NOTE: Formatting causes the loss of information stored on the hard drive.
Pressing the OK button confirms the intention to format the disk.
The status of the disk should be "READ AND WRITE" after successful formatting.
NVR-6332-H8/FR-II Quick start guide version 1.1
All rights reserved © AAT Systemy Bezpieczeństwa sp. z o.o.
20
NVR OPERATING
3.4. Startup configuration
After the first start of the NVR, the setup wizard window is displayed (if the function has not been
disabled before). In order to properly configure the recorder, follow these steps with the procedure:
Note:
For suggested values for IP camera setting please refer to the Cameras Capability Table
available on the www.novuscctv.com website. If you set wrong values some problems may
appear: the NVR cannot search the IP camera, the stream cannot be connected, the image is not
fluent, the image quality is bad and so on.
Before starting work with the network recorder, you must perform the initial configuration of the
device. At the bottom of the window, checkbox Enable wizard next time is checked. If you uncheck
this box, the wizard will not start at the next restart.
Click Wizard Setup to start.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68

Novus NVR-6332-H8/FR-II Instrukcja obsługi

Typ
Instrukcja obsługi

w innych językach

Inne dokumenty