CAUTIONS AND WARNINGS
THE PRODUCT MEETS THE REQUIREMENTS CONTAINED IN THE FOLLOWING DIRECTIVES:
Exclusion of liability in the event of damage to data contained on disks or other devices or media:
The manufacturer is not liable in the event of damage or loss of data contained on disks or other
devices or carriers during the operation of the Product.
Obligation to consult the Manufacturer before performing any action not provided for in the
instruction manual or other documents:
Before performing an action that is not provided for a given Product in the user manual, other
documents attached to the Product or does not result from the normal purpose of the Product, it is
necessary, under pain of exclusion of the Manufacturer's liability for the consequences of such action,
to contact the Manufacturer.
Pictures in this publication showing camera views can be simulations. Actual camera
images may vary depending on the type, model, settings, observation area, or
environmental conditions.
DIRECTIVE 2014/30/EU OF THE EUROPEAN PARLIMENT AND OF THE
COUNCIL of 26 February 2014 on the harmonization of the laws of the Member States
relating to electromagnetic compatibility (OJ L 96, 29.3.2014, p. 79106, with changes).
DIRECTIVE 2012/19/EU OF THE EUROPEAN PARLIAMENT AND OF THE
COUNCIL of 4 July 2012 on waste electrical and electronic equipment WEEE)
(OJ L 197, 24.7.2012, p. 3871, with changes).
DIRECTIVE 2011/65/EU OF THE EUROPEAN PARLIAMENT AND OF THE
COUNCIL of 8 June 2011 on the restriction of the use of certain hazardous substances in
electrical and electronic equipment (OJ L 174, 1.7.2011, p. 88110, with changes).
COMMISION DELEGATED DIRECTIVE (EU) 2015/863 of 31 March 2015 amending
Annex II to Directive 2011/65/EU of the European Parliament and of the Council as regards
the list of restricted substances.
DIRECTIVE (EU) 2017/2102 OF THE EUROPEAN PARLIAMENT AND OF THE
COUNCIL of 15 November 2017 amending Directive 2011/65/EU on the restriction of the
use of certain hazardous substances in electrical and electronic equipment.
DIRECTIVE 2014/35/EU OF THE EUROPEAN PARLIAMENT
AND OF THE COUNCIL of 26 February 2014 on the harmonisation
of the laws of the Member States relating to the making available on the
market of electrical equipment designed for use within certain voltage limits.
NVR-6408-H1/F-II Quick start guide version 1.0
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA sp. z o.o.
3
SAFETY REQUIREMENTS
1. Please read this manual carefully before installation and operation;
2. Please keep this manual for the lifespan of the device in case referring to the contents of this
manual is necessary;
3. It is necessary to comply with the safety requirements described in the manual, as they have a
direct impact on the safety of users and the durability and reliability of the device;
4. All activities performed by installers and users must be carried out as described in the manual;
5. The device should be disconnected from power sources during maintenance procedures;
6. It is not allowed to use any additional devices, components or accessories not provided for and not
recommended by the manufacturer;
7. Do not install this device in places where proper ventilation cannot be provided (e.g. closed
cabinets, etc.), as this may cause heat build-up and may result in damage;
8. Do not place the device on unstable surfaces. Installation must be carried out by qualified
personnel with appropriate permissions in accordance with the recommendations provided in this
manual;
9. The device may be powered only from sources with parameters compliant with those indicated by
the manufacturer in the technical data;
Before using the device, read the instruction manual in order to ensure proper and safe operation
of the device. Failure to comply with the instructions may lead to damage to the device and/or
safety violations.
The user may not repair the device himself. Repairs and maintenance of the device may only be
performed by qualified service personnel.
The device, which is an element of a professional CCTV system used for supervision and
control, is not intended for self-assembly in households by persons without specialist
knowledge.
As the product is constantly improved and optimised, some of its parameters and functions may have
changed from those described in this manual. If in doubt, please refer to the user manual at
www.novuscctv.com
The user manual located at www.novuscctv.com is always the most up-to-date version.
NVR-6408-H1/F-II Quick start guide version 1.0
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA sp. z o.o.
4
FOREWORD INFORMATION
1. FOREWORD INFORMATION
1.1. Main characteristics
Network Video Recorder for 8 IP cameras.
2 x Gigabit Ethernet port.
Recording resolution up to 5520 x 2400 .
H.264, H.265, H.265+, H.265 Smart compression.
Recording stream up to 160 Mb/s in total from all cameras.
ONVIF protocol support.
Dual stream recording
Support 1 x SATA 3,5” HDDs. *
Operating system based on Linux.
Main monitor 1 x HDMI (4K UltraHD), 1 x VGA (FullHD).
Spot monitor 1 x VGA (FullHD) - single camera, any division of the screen, sequence of any screen
divisions.
Exception, Scene Change, Video Blurred, Video Color Cast, Tripwire, Zone entrance, Abandoned
Object, Object Disappearance, Face Recognition, Perimeter Intrusion Detection by pedestrian or
vehicle, Line Cross Detection by pedestrian or vehicle, Analysis of Recognized Number Plate
Numbers (LPR) **
Backup: onto HDD or USB Flash Memory through USB port and through the IP network.
Software: N Control 6000 (application for remote administration, live monitoring and recorded data
search).
N-VID6 application for live and playback functions from mobile devices.
User friendly multi-lingual OSD.
IR remote controller and PC mouse included
* List of compatible HDD models and maximum capacities is available on the product website
www.novuscctv.pl in the DOWNLOADABLE FILES tab in the "HDD Compatible disks" file.
** Functions depend on connected camera model.
NVR-6408-H1/F-II Quick start guide version 1.0
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA sp. z o.o.
5
1.2. Recorderstechnical data
*** With dualstream mode.
NVR-6408-H1/F-II
Video
IP Cameras up to 8 channels at 5520 x 2400 resolution (video + audio)
Compression H.264, H.265, H.265+, H.265 Smart
Monitor Output main (split screen, full screen, sequence): 1 x VGA, 1 x HDMI (4K UltraHD)
(up to 2 monitors simultaneously), spot: 1 x VGA (FullHD)
Dualstreaming Support yes
Fisheye Support yes, 6000 IP series cameras
using Internet Explorer, N-VID6, N Control 6000
Audio
Audio Input/Output 1 x line-in (RCA) / 1 x HDMI, 1 x line-out (RCA)
Recording
Recording Speed 240 fps (8 x 30 fps for 5520 x 2400 and lower)
Stream Size 160 Mb/s in total from all cameras
Recording Mode continuous, triggered by: manual, alarm input, motion detection, face recogni-
tion, intelligent image analysis functions
Prealarm/Postalarm up to 5 s/up to 600 s
Display
Display Speed 240 fps (8 x 30 fps) ***
Playback
Playback Speed 240 fps (8 x 30 fps) ***
Recorded Data Search by date/time, events, image analysis events, POS, motion in a defined area, rela-
ted to face recognition, tags, licence plate number
Backup
Backup Methods USB port (HDD or Flash memory), network
Backup File Format MP4, AVI, RPAS (player included)
Storage
Internal Storage available mount: 1 x HDD 3.5” 10 TB SATA
Total Internal Capacity 10 TB
Alarm
Internal Alarm Input/
Output 8/4 relay type
Camera Alarm Input/
Output supports IP cameras alarm input/output
Motion Detection supports cameras motion detection
System Reaction to
Alarm Events
buzzer, alarm output activation, recording activation, PTZ, e-mail with ata-
tchment, Full Screen, PUSH message, voice prompt, snapshot
Intelligent image analysis
Supported Functions
Exception, Scene Change, Video Blurred, Video Color Cast, Tripwire, Zone
entrance, Abandoned Object, Object Disappearance, Face Recognition, Perime-
ter Intrusion Detection by pedestrian or vehicle, Line Cross Detection by pe-
destrian or vehicle, Analysis of Recognized Number Plate Numbers (LPR)
Database Capacity 10000 faces
50000 license plates
Other parameters face recognition for 6 NOVUS 6000 series IP cameras with "F" in the model
name or 2 ONVIF cameras
FOREWORD INFORMATION
NVR-6408-H1/F-II Quick start guide version 1.0
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA sp. z o.o.
6
FOREWORD INFORMATION
The availability of individual functions (including image analysis) depends on the model of the
cameras used, as well as the software version of the recorder and cameras.
In order to create face recognition system, please deploy NOVUS 6000 series IP cameras with "F" in
the model name.
Presented display and playback speeds are achieved using dual-streaming. Detailed data on hard drives
can be found at www.novuscctv.com in the compatibility table available in the DOWNLOADABLE
FILES tab.
1.3. Package contents
Unpack the device carefully. After unpacking, please ensure that package contains the following items:
Network Video Recorder
USB Mouse
Remote control
Power supply 12VDC
Quick start guide
If any of the elements has been damaged during transport, pack all the elements back into the original
packaging and contact your supplier.
NVR-6408-H1/F-II
Network
Network Interface 2 x Ethernet - RJ-45 interface, 10/100/1000 Mbit/s
Network Protocols
Support
HTTP, TCP/IP, IPv4/v6, HTTPS, FTP, DHCP, DNS, DDNS, NTP, RTSP,
UPnP, SNMP, IEEE 802.1X, PPPoE, SMTP, P2P, POS, HTML5
ONVIF Protocol
Support Profile S (ONVIF 2.2 or higher)
PC/MAC Software NMS, Internet Explorer, Firefox, Chrome, Opera, N Control 6000, Edge/
Safari, N Control 6000
Mobile applications N-VID6 (iPhone, Android)
Number of Simulta-
neous Connections
up to 64 clients, up to 12 main streams or 32 substreams or 8 playback streams
in total
Bandwidth 160 Mb/s in total to all client workstations
PTZ
PTZ Functions pan/tilt/zoom, preset commands
Auxiliary Interfaces
USB Ports 2 x USB 2.0, 1 x USB 3.0
Operating system
Operating System Linux
OSD languages: Polish, English, others
Control PC mouse and IR remote controller (in-set included), network
System Diagnostic automatic control of: HDDs, network, camera connection loss
Security password protection, IP filtering, MAC filtering, ARP guard
Installation parameters
Dimensions (mm) 300 (W) x 44 (H) x 248 (D)
Weight 1.2 kg (without HDD)
Power Supply 100 ~ 240 VAC
Power Consumption 20 W (with 1 HDD)
Operating Temperature -10°C ~ 50°C
NVR-6408-H1/F-II Quick start guide version 1.0
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA sp. z o.o.
7
STARTING THE DEVICE
NOTE!
ONVIF protocol support was verified with IP cameras based on ONVIF ver. 2.2 and compatible
with the "PROFILE S".
Implementation of the ONVIF protocol by different manufacturers may vary by some functions,
which can make them work improperly or not in accordance with expectation. AAT SYSTEMY
BEZPIECZEŃSTWA SP. Z O.O. is not responsible for incompatibility problems resulting from
cameras of other brands than NOVUS, which are using ONVIF protocol. If you are using
ONVIF protocol cameras other than NOVUS brand it is recommended to test each time whether
required functions work correctly.
2. STARTING THE DEVICE
2.1 Electrical connection and other back panel elements.
NVR-6408-H1/F-II
1. CONNECTORS : Block of alarm input/output connectors.
2. AUDIO IN: Audio mono input to connect microphone.
3. AUDIO OUT : Audio output.
4. LAN1: RJ-45 connector port to connect to the local network and Internet.
5. LAN2: RJ-45 connector port to connect to the local network and Internet.
6. HDMI: HDMI connector, use the HDMI cable to connect monitor.
7. VGA: D-SUB connector, to connect VGA monitor.
8. USB 3.0 : USB 3.0 port for external Flash memory and other USB devices.
9. USB 2.0: USB 2.0 port for external Flash memory and other USB devices.
10. POWER SOCKET: To plug in the 12V power cord.
2
1
3
5
4
6
7
8
9
10
NVR-6408-H1/F-II Quick start guide version 1.0
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA sp. z o.o.
8
STARTING THE DEVICE
2.2 HDD mounting
Novus NVR-6408-H1/F-II support 1 internal SATA HDD.
NOTE!
In order to find information regarding the compatible models of HDDs and their maximum
capacities, please contact Novus distributor or check the information presented at
www.novuscctv.com. AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O. company is not
responsible for any problems from using not recommended hard drives.
The list of compatible HDDs contains all the HDDs that can be used with a given DVR including
HDDs designed for office use - so called desktop disks. However, due to the fact that reliability of
the recording process and data safety are paramount factors of any CCTV system, we strongly
advise to use HDDs designed for continuous (24/7) operation.
You need to format disks if they were used in a different device. All data saved on HDD prior to
format will be lost.
HDD Installation
In order to mount HDD, unscrew the five screws in the places shown in the picture below (3 screws at
the back, 2 at the sides) and remove the recorder housing by sliding it back and then lifting it up.
NOTE!
Before removing top cover unplug the power cord from the NVR. When NVR is turned on before
disconnecting the power cord, shut down the recorder using the NVR menu.
If you use the disk previously used in another device, it is necessary to format it before using.
Formatting the drive erase all the data from disk. All drives in the recorder should be exactly the
same type.
By default, SATA cables are packed together with NVR accessories, while HDD power cable is
connected to the NVR PSU and ready for connecting the HDD.
NVR-6408-H1/F-II Quick start guide version 1.0
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA sp. z o.o.
9
STARTING THE DEVICE
After removing the casing, mount the disk using mounting screws (4 pcs.), and then connect the power
and signal cables.
After connecting the hard drive mount the cover and start it to check the correctness of connections and
format the hard drive.
NOTE!
If the device was brought from a location with lower temperature, please wait until it reaches the
temperature of location it is currently in. Turning the device on immediately after bringing it
from a location with lower ambient temperature is forbidden, as the condensing water vapour
may cause short-circuits and damage the device as a result.
2.3. Connecting the power supply.
Please connect provided power cord in the rear power port of the NVR like depicted below.
Initialization lasts approximately 60 seconds. During this time executing any device functions and
pressing any buttons is prohibited. To shut down the device please use the menu.
NOTE!
Do not place the power cord under the carpet or rug. The power cord is usually earth-grounded.
However, even if it's not earth-grounded, never modify it on your own for earth-grounding.
Make sure that power adapter is placed near of NVR and secured from accidental disconnection.
If the device was brought from a location with lower temperature, please wait until it reaches the
temperature of location it is currently in. Turning the device on immediately after bringing it
from a location with lower ambient temperature is forbidden, as the condensing water vapour
may cause short-circuits and damage the device as a result.
Before starting the device familiarize yourself with the description and the role of particular
inputs, outputs and adjusting elements that the device is equipped with.
NVR-6408-H1/F-II Quick start guide version 1.0
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA sp. z o.o.
10
2.4. Connecting monitor
This product supports following interfaces for main monitor: HDMI, VGA.
For HDMI following resolutions are supported: 1024x768, 1280x1024, 1920x1080 and 3840x2160.
2.5. Connecting camera and Network
The NVR-6408-H1/F-II has two Ethernet ports for connecting the NVR in two modes. The first mode
in the recorder menu called MULTIPLE ADDRESS SETTING allows to connect NVR to networks
with different IP addresses. This mode allows to separate cameras network and NVR access network.
The second mode, called NETWORK FAULT TOLERNACE allows one of network sockets of the
recorder to be used as an active fault tolerant connection in case of the main connection fails.
The permissible cable distance from the switch to each camera is 100m. Cameras, Internet and other
devices should be connected as shown below.
We recommend that you configure the camera before connecting to a recorder, as described in the
user manual of the camera. Please note that cameras have addressed the unique IP address supported
by the recorder. .
Connecting cameras and network recorder NVR-6408-H1/F-II in MULTIPLE ADDRESS
SETTING
STARTING THE DEVICE
NOVUS NVR
INTERNET
PC
COMPUTER
IP CAMERAS
1-8
NETWORK SWITCH ROUTER
NVR-6408-H1/F-II Quick start guide version 1.0
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA sp. z o.o.
11
Connecting NVR-6408-H1/F-II and cameras in NETWORK FAULT TOLERNACE mode.
Before configuring the connection of the cameras in the recorder, we recommend using a PC to
configure the cameras according to the instructions of the camera.
NOTE!
In order to ensure stability and protection against overload and unauthorized access, we
recommend separating the camera network from the access network to the NVR.
2.6. Connecting external devices
Connecting audio ports
The audio output allows to connect a loudspeaker with an amplifier. The signal at the audio output is
about 200mV with an impedance of 1kΩ.
Connecting USB devices
NVR has 1 x USB 2.0 port on front panel, 1 x USB 3.0 and 1 x USB 2.0 on back. They could be used
to connect external Flash memory, mouse and other USB compatible devices. To connect storage
memory it is recommended to use USB 3.0 port.
STARTING THE DEVICE
NOVUS NVR
INTERNET PC
COMPUTER
IP CAMERAS 1-8
NETWORK SWITCH
ROUTER
BACKUP CONNECTION
NVR-6408-H1/F-II Quick start guide version 1.0
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA sp. z o.o.
12
STARTING THE DEVICE
Connecting alarms ports
NVR-6408-H1/F-II has local alarm input and output. The connection diagram of the alarm output
no. 1 is presented below. Other outputs should be connected according to the same scheme.
Below is a diagram of connecting the sensor to the alarm input.
NO1 COM1 ALARM
Power
source
ALARM
IN1 IN2 ... IN8 GND SENSOR
NVR-6408-H1/F-II Quick start guide version 1.0
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA sp. z o.o.
13
STARTING THE DEVICE
2.7. Security recommendations for network architecture and configuration
NOTE!
Below are shown security recommendations for network architecture and configuration
of CCTV systems that are connected to the Internet to reduce the risk
of unauthorized interference with the system by a third party.
1. Absolutely change the default passwords and user names (if the device gives this possibility)
of all applied network devices (recorders, cameras, routers, network switches,
etc.) to the severely complexity password. Use lowercase and uppercase letters, numbers, and special
characters if there is such possibility.
2. Depending on the available functionality in the order to restrict access to the used network devices
at the administrator account level, it is recommended to configure the users accounts accordingly.
3. Do not use DMZ function (Demilitarized zone) in your router. Using that function you open
the access to recorder system from the Internet on all ports, which gives possibility for
an unauthorized interference with the system.
Instead of DMZ use port forwarding redirect only the ports which are necessary for the performance
of the connection (detailed information about ports of communication in different models of recorders,
cameras, etc. can be found in the operating instructions).
4. Use routers with firewall function and make sure it is enabled and properly configured.
5. It is recommended to change the default network communication port numbers of used devices
if there is such possibility.
6. If used network devices has a UPnP feature and it is not used, turn it off.
7. If used network devices has a P2P feature and it is not used, turn it off.
8. If used network devices support HTTPS protocol for connection, it is recommended to use it.
9. If used network devices support IP filtering for authorized connections function, it is recommended
to use it.
10. If used recorder has two network interfaces it is recommended to use both of them to physically
separate network for cameras and network for Internet connection. The only device in the system,
accessible from Internet is recorder - there is no physically access directly to any camera.
NVR-6408-H1/F-II Quick start guide version 1.0
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA sp. z o.o.
14
NVR OPERATING
3. NVR OPERATING
3.1. Front panel description
1. LED Diodes for monitoring NVR activity.
- REC - monitors recording activity
- NET - monitors networking activity
- PWR - activities when power is on
2. USB USB 2.0 port for external Flash memory and mouse connection.
.
3.2. Controlling via USB mouse
It is possible to control NVR via an USB mouse connected to the USB port. Double-click on any
camera in split screen display mode switches the display to full-screen mode. Subsequent double-click
returns to previous display mode. During configuration, the selection of individual items is made using
the left mouse button. In selected positions, the value of a selected field can be changed using the
mouse wheel.
3.3. First Launch Wizzard
In order to start the device, connect the power cable to the power supply, turn on the switch located on
the back of the housing and wait for the recorder menu to start.
After the NVR first launch, a window is displayed that allows to select the language and location. To
select the English language, select ENGLISH in the left-hand window and select the recorder location
in the right-hand window.
1
2
NVR-6408-H1/F-II Quick start guide version 1.0
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA sp. z o.o.
15
NVR OPERATING
In the next step, read and accept the Privacy Statement. Check the checkbox at the bottom of the
window and press OK.
NVR-6408-H1/F-II Quick start guide version 1.0
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA sp. z o.o.
16
NVR OPERATING
The next wizard window allows to set time parameters such as TIME ZONE, SYSTEM TIME, DATE
FORMAT, TIME FORMAT, DST, SYNCHRONOUS, NTP SERVER and VIDEO FORMAT. After
making your selection, click the NEXT button.
Change the password in the password change wizard. The password must be at least 8 characters long.
It should contain a number, and upper and lower case letters. Enter them on the screen keyboard
available after clicking in the NEW PASSWORD and CONFIRM PASSWORD fields.
NVR-6408-H1/F-II Quick start guide version 1.0
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA sp. z o.o.
17
NVR OPERATING
To display the entered password, check the DISPLAY PASSWORD box. Selecting LOG IN
AUTOMATICALLY checkbox will automatically log the user into the system after starting the
recorder.
By selecting the ENABLE field in the PATTERN LOCK row, it is possible to activate the setting of
enabling access for the user by means of a graphic pattern instead of entering the password. To start
the graphic symbol settings, click the EDIT button. Then, holding down the left mouse button, move
the cursor between the displayed circles twice to mark the pattern that will be used to unlock the
device.
After clicking on the NEXT button, a window is displayed that allows you to set a set of questions and
answers that can unlock access to the recorder.
NVR-6408-H1/F-II Quick start guide version 1.0
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA sp. z o.o.
18
NVR OPERATING
To add a question, click on the QUESTION field to enter the question using the keyboard. Then click
on the ANSWER field to enter the answer to the question. Clicking on the ADD button adds a set of
questions and answers. Clicking the NEXT button takes you to the window in which information about
the disk connected to the recorder is displayed.
If the STATUS field displays information about the inaccessibility of the disk, format the disk by
clicking on the FORMAT button. A window appears asking to confirm that you want to format the
disk.
NOTE!
Formatting causes the loss of information stored on the hard drive.
Pressing the OK button confirms the intention to format the disk.
The status of the disk should be "READ AND WRITE" after successful formatting.
NVR-6408-H1/F-II Quick start guide version 1.0
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA sp. z o.o.
19
NVR OPERATING
3.4. Startup configuration
After the first start of the NVR, the setup wizard window is displayed (if the function has not been
disabled before). In order to properly configure the recorder, follow these steps with the procedure:
NOTE!
For suggested values for IP camera setting please refer to the Cameras Capability Table
available on the www.novuscctv.com website. If you set wrong values some problems may
appear: the NVR cannot search the IP camera, the stream cannot be connected, the image is not
fluent, the image quality is bad and so on.
Before starting work with the network recorder, you must perform the initial configuration of the
device. At the bottom of the window, checkbox Enable wizard next time is checked. If you uncheck
this box, the wizard will not start at the next restart.
Click Wizard Setup to start.
NVR-6408-H1/F-II Quick start guide version 1.0
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA sp. z o.o.
20
NVR OPERATING
I. NETWORK SETTINGS:
The first tab of the setup wizard is Network Settings. The recorder has two network cards and they can
work in two modes - Multiple Address Setting or Network fault tolerance. The first one requires that
network cards have different IP addresses from different address groups. Each LAN port must be
connected to separate network. The second mode allows to assign only one IP address, it is assigned to
both ports - in case of damage to one connection, the other port takes over the connection. Both ports
should then be connected to the same network.
The recorder is enabled to obtain an IP address automatically by default. It gets IP address and DNS
settings from the DHCP server. If the address retrieval fails, the recorder is assigned a default address
of 192.168.1.100 with a subnet mask of 255.255.255.0. If we want to edit these settings, disable the
Obtain an IP address automatically checkbox and assign the appropriate IP address, subnet mask,
gateway, DNS addresses. You can do the same for the second port.
At the bottom of the window, you can define HTTP, HTTPS ports and the server data port.
Parameter changes must be confirmed with the NEXT button
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64

Novus NVR-6408-H1/F-II Instrukcja obsługi

Typ
Instrukcja obsługi

w innych językach