Wolf SEM-1 Assembly Instructions Manual

Typ
Assembly Instructions Manual
Art.-Nr.: 3043754_201508
Wolf GmbH · Postfach 1380 · D-84048 Mainburg · Tel. +49-8751/74-0 · Fax +49-8751/741600 · Internet: www.wolf-heiztechnik.de
DE
Montageanleitung
Solarspeicher SEM-1
Seite 2 - 8
GB
Assembly Instructions
Solar tank SEM-1
Page 9 - 16
IT
Istruzioni di montaggio
Bollitore solare SEM-1
Pagina 17 - 24
ES
Instrucciones de montaje
Acumulador solar SEM-1
Página 25 - 32
BEFR
Instructions de montage
Chauffe-eau solaire SEM-1
Page 33 - 40
BENL
Montageaanwijzingen
Zonneboiler SEM-1
Pagina 41 - 48
SK
Montážny návod
Solárny ohrievač vody SEM-1
Strana 73 - 80
CZ
Montážní návod
Solární ohřívač vody SEM-1
Strana 81 - 88
GR
Οδηγίες συναρμολόγησης
Ηλιακό μποϊλερ SEM-1
Σελίδες 89 - 96
PL
Instrukcja montażu
Zasobnik solarny SEM-1
Strona 57 - 64
HU
Szerelési Utasítás
SEM-1 szolár melegvíz-tároló
leírás a 65 - 72 oldalon
DK
Montagevejledning
Solvarmebeholder SEM-1
Side 49 - 56
SEM-1
2 3043754_201508
Sicherheitshinweise/
Kurzbeschreibung
Durch den Betrieb des Speichers unter 60°C kann in erheblichem Umfang Energie
eingespart werden.
Ideale Betriebstemperaturen liegen bei 50-60°C.
Wärmeverluste und Verkalkung sind in diesem Bereich wesentlich reduziert.
Hinweis
Solarspeicher Typ SEM-1 aus Stahl S235JR mit Gütenachweis (mit seitlichem
Flansch).
Korrosionsschutz durch Doppelschicht-Emaillierung von Behälterinnenwand und
Heizschlange nach DIN 4753 Teil 3. Zusätzlicher Korrosionsschutz durch Magnesium-
Schutzanode, bei allen Wasserverhältnissen und in jedem Leitungsnetz einsetzbar.
Solarspeicher SEM-1
Inhaltsverzeichnis
Sicherheitshinweise und Kurzbeschreibung .................................................................2
Technische Daten .........................................................................................................3
Verrohrung ....................................................................................................................4
Aufstellung / Montage ...................................................................................................5
Regelung für Ladepumpe .............................................................................................6
Inbetriebnahme - Wartung ............................................................................................7
In dieser Beschreibung werden die folgenden Symbole und Hinweiszeichen
verwendet. Diese wichtigen Anweisungen betreffen den Personenschutz und die
technische Betriebssicherheit.
"Sicherheitshinweis" kennzeichnet Anweisungen, die genau einzuhalten
sind, um Gefährdung oder Verletzung von Personen zu vermeiden und
Beschädigungen am Gerät zu verhindern.
Gefahr durch elektrische Spannung an elektrischen Bauteilen!
Achtung: Vor Abnahme der Verkleidung Betriebsschalter ausschal-
ten.
Greifen Sie niemals bei eingeschaltetem Betriebsschalter an elektrische
Bauteile und Kontakte! Es besteht die Gefahr eines Stromschlages mit
Gesundheitsgefährdung oder Todesfolge.
An Anschlußklemmen liegt auch bei ausgeschaltetem Betriebsschalter
Spannung an.
"Hinweis" kennzeichnet technische Anweisungen, die zu beachten sind,
um Schäden und Funktionsstörungen am Gerät zu verhindern.
Achtung
Sicherheitshinweise
SEM-1
3043754_201508 3
Technische Daten
B
A
C
D
F
E
H
I
J
K
L
M
N
O
G
Speicher Typ SEM-1 500 750 1000
Speicherinhalt Ltr. 500 750 935
Speicherdauerleistung 80/60-10/45°C kW - Ltr./h 20-490 50-1200 50-1200
Leistungskennzahl (Heizung)
NL
60
6 13,5 18
Kaltwasseranschluss A mm 99 220 220
Rücklauf Solar B mm 305 345 345
Speicherfühler Solar C mm 586 603 603
Vorlauf Solar D mm 865 920 975
Rücklauf Heizung E mm 985 1025 1340
Speicherfühler Heizung F mm 1160 1185 1500
Zirkulation G mm 1195 1290 1605
Vorlauf Heizung H mm 1335 1475 1790
Warmwasseranschluss I mm 1451 1590 1940
Flansch (unten) J mm 335 384 384
Elektrozusatzheizung K mm 949 970 1145
Thermometer L mm 1404 1460 1810
Gesamthöhe M mm 1780 1850 2200
Durchmesser mit Wärmedämmung N mm 850 1000 1000
Durchmesser ohne Wärmedämmung
O mm - 800 800
Kippmaß mit Wärmedämmung
mm 1935 2030 2350
Primär-Heizwasser bar/°C 10/110 10/110 10/110
Sekundär-Brauchwasser bar/°C 10/95 10/95 10/95
Flanschinnendurchmesser mm 114 114 114
Kaltwasseranschluss G (IG) 1“ 1¼“ 1¼“
Heizungs-/Solarvorlauf G (IG) 1“ 1¼“ 1¼“
Heizungs-/Solarrücklauf G (IG) 1“ 1¼“ 1¼“
Zirkulation G (IG) ¾“ 1“ 1“
Warmwasseranschluss G (IG) 1“ 1¼“ 1¼“
Elektrozusatzheizung G (IG) 1½“ 1½“ 1½“
Thermometer G (IG) ½“ ½“ ½“
Wärmetauscheräche (Heizung) 0,95 1,5 1,5
Wärmetauscheräche (Solar) 1,8 2,1 2,4
Wärmetauscherinhalt (Heizung) Ltr. 6,1 9,15 9,15
Wärmetauscherinhalt (Solar) Ltr. 11,5 13,5 14,5
Gewicht kg 182 290 350
SEM-1
4 3043754_201508
Verrohrung
Anschluß Solarspeicher SEM-1
an Heizkessel und Kollektorfeld
Tauchhülse Thermometer
Elektrozusatzheizung
Speicherfühler Heizung
Speicherfühler Solar
Warmwasseranschluß
Heizungsvorlauf
Zirkulation
Heizungsrücklauf
Solarvorlauf
Solarrücklauf
Kaltwasseranschluß
nach DIN 1988
Anlagenschema
À Kollektorfeld
Á Entlüftungstopf
 Kollektorfühler
à Solarmodul
Ä Solarpumpengruppe
Å Speicherfühler Solar
Æ Füll- und Entleerungshahn
Ç Solarspeicher SEM-1
È Heizkessel
É Speicherfühler Heizung
SEM-1
3043754_201508 5
Aufstellung / Montage
Aufstellung
Der Solarspeicher darf nur in einem frostgeschützten Raum aufgestellt werden, an-
dernfalls muß bei Frostgefahr der Speicher, sowie alle wasserführenden Armaturen
und Anschlußleitungen entleert werden!
Eisbildung in der Anlage kann zu Leckagen und Zerstörung des Speichers führen!
Beim Entleeren der Anlage kann heißes Wasser austreten und Verletzungen,
insbesondere Verbrennungen verursachen!
Der Aufstellungsort muß den notwendigen Raum für Wartung und Reparatur, sowie eine
ausreichende Tragfähigkeit des Untergrundes gewährleisten!
Wärmedämmung
Die Wärmedämmung des Speichers muß vor der Verrohrung angebracht werden!
Feuer, Lötamme bzw. Schweißbrenner nicht in die Nähe der Dämmung bringen.
Achtung: Brandgefahr!
Trinkwasserlter
Da eingeschwemmte Fremdteile Armaturen usw. verstopfen und Korrosion in den Lei-
tungen verursachen, wird empfohlen in der Kaltwasserzuleitung einen Trinkwasserlter
zu installieren.
Achtung
Druckminderer
Der Einbau eines Druckminderventils wird empfohlen. Der zulässige Betriebsdruck des
Solarspeichers beträgt brauchwasserseitig 10 bar. Wird das Versorgungsnetz mit einem
höheren Druck betrieben, muß ein Druckminderer einbaut werden.
Eine Überschreitung des zulässigen Betriebsdruckes kann zu Leckagen und
Zerstörung des Speichers führen!
Zur Verminderung der Fließgeräusche innerhalb von Gebäuden sollte der Leitungsdruck
auf ca. 3,5 bar eingestellt werden.
Der Solarspeicher ist so zu installieren, daß er ohne Demontage entleert werden kann.
Entleerung
Warm-/Kaltwasseranschluß
Solarspeicher
Vor der Rohrinstallation Wärmedämmung anbringen.
Der Solarspeicher ist nach dem Verrohrungs-Schema auf Seite 4 anzuschließen. Es darf
nur ein bauteilgeprüftes Sicherheitsventil verwendet werden. Zwischen Solarspeicher
und Sicherheitsventil darf keine Absperreinrichtung eingebaut werden.
Ist der Speicher an den Warm- und Kaltwasseranschlüssen mit nicht metallischen
Rohrwerkstoffen verbunden, so muss der Speicher geerdet werden!
Der Einbau von Schmutzfängern oder anderen Verengungen in die Verbindungsleitung
zwischen Solarspeicher und Sicherheitsventil ist unzulässig.
Der Mindest-Anschlußdurchmesser des Sicherheitsventils muß DN20-¾" betragen.
Die Ausblaseleitung muß mindestens in Größe des Sicherheitsventil-Austrittsquerschnitt
ausgeführt werden, darf höchstens 2 Bögen aufweisen und höchstens 2 m lang sein.
Werden aus zwingenden Gründen 3 Bögen oder eine Länge bis zu 4 m erforderlich,
so muß die gesamte Ausblaseleitung eine Nennweite größer ausgeführt werden. Mehr
als 3 Bögen sowie eine Länge über 4 m sind unzulässig. Die Ausblaseleitung muß mit
Gefälle verlegt sein. Die Ablaueitung hinter dem Ablauftrichter muß mindestens den
doppelten Querschnitt des Ventileintritts aufweisen. In der Nähe der Ausblaseleitung
des Sicherheitsventils, zweckmäßig am Sicherheitsventil selbst, ist ein Hinweisschild
anzubringen mit der Aufschrift:
"Während der Beheizung tritt aus Sicherheitsgründen Wasser aus der Ausblase-
leitung aus! Nicht verschließen!"
Bei der Wahl des anlagenseitigen Installationsmaterials ist auf die Regeln der Technik
sowie auf eventuelle mögliche elektrochemische Vorgänge zu achten (Mischinstalla-
tion)! Der Speicher kann mit einer Elektrozusatzheizung ausgerüstet werden, die mit
einem Sicherheitstemperaturbegrenzer ausgestattet ist. Dieser schaltet im Falle einer
Fehlfunktion die weitere Beheizung bei max. 110° C ab.
Die betreffenden Anschlußkomponenten sind für diese Temperatur auszulegen
oder die Temperatur über ein Mischventil zu begrenzen!
Bei Brauchwassertemperaturen über 60°C wird generell empfohlen, diese über ein
Mischventil auf 60°C zu begrenzen!
Heißes Wasser kann Verletzungen, insbesondere Verbrühungen verursachen!
Achtung
Achtung
Achtung
Achtung
SEM-1
6 3043754_201508
Regelung für Ladepumpe
Elektronischen Speichertemperaturfühler der Heizungsregelung in die obere Tauchhül-
se für Speicherfühler des Solarspeichers stecken und mit Fühlerhalter befestigen. Bei
Speichern mit Fühlerkanal, Fühler senkrecht nach unten, bis Anschlag einschieben.
Gewünschte Speichertemperatur am Speichertemperaturregler der Heizungsregelung
einstellen. (max. 60°C).
Witterungsgeführte Heizungsregelung
(Heizungsregelung mit integriertem
Speichertemperaturregler und Spei-
chertemperaturfühler)
Elektrozusatzheizung E2 / E4,5 / E6
Elektrozusatzheizung
Die Vorschriften und Bestimmungen des VDE und der örtlichen Energie-Versorgungs-
unternehmen sind zu beachten.
Der Anschluß muß durch einen konzessionierten Elektroinstallateur erfolgen.
Geräte vor dem Öffnen stromlos machen! Berühren Sie niemals unter Strom
stehende Bauteile - es besteht die Gefahr von Verletzung oder Tod!
Deckel von Elektrozusatzheizung abschrauben und gemäß beiliegender Anleitung an
Netz 230 oder 400 V~ anschließen. Anschlußkabel muß bauseits gestellt werden.
Elektrozusatzheizung 2 kW/230V~, 4,5 kW/400 V~, 6 kW/400 V~.
mit eingebautem Speichertemperaturregler und Sicherheitstemperaturbegrenzer.
Elektrozusatzheizung in die 1 1/2" Muffe am Solarspeicher eindrehen und
abdichten.
SEM-1
3043754_201508 7
Inbetriebnahme - Wartung
Inbetriebnahme
Die Aufstellung und erste Inbetriebnahme darf nur durch eine anerkannte Installations-
rma erfolgen.
Nach der Montage Rohre und Speicher gründlich durchspülen, Speicher mit Wasser
füllen. Warmwasserzapfhahn öffnen bis Wasser ausläuft und Sicherheitsventil durch
Anlüften überprüfen.
Vor Inbetriebnahme Speicher unbedingt füllen und entlüften!
Achtung: Max. Betriebsdruck von 10 bar darf nicht überschritten werden!
Eine Überschreitung des zulässigen Betriebsdruckes kann zu Leckagen und
Zerstörung des Speichers führen!
Betrieb mit Ladepumpe:
Speichertemperaturregler auf gewünschte Temperatur (max. 60°C) einstellen. Bei
Anschluß eines elektronischen Speicherfühlers wird die Speichertemperatur an der
Kesselregelung eingestellt.
Betrieb mit Elektrozusatzheizung E2 / E4,5 / E6
Speichertemperaturregler der Heizungsregelung auf 20°C einstellen.
Speichertemperaturregler der Elektrozusatzheizung auf gewünschte Temperatur
(max.60°C) drehen.
Frostschutz
Zur Energieeinsparung bei längerer Abwesenheit kann der Speichertemperaturregler
ganz nach links (gegen Uhrzeigersinn) gedreht werden, dabei bleibt die Frostschutz-
funktion erhalten.
Wartung
Magnesiumanode
Die Anlage ist alle 2 Jahre durch eine Fachrma überprüfen zu lassen.
Bei eingebauter Magnesiumanode beruht die Schutzwirkung auf elektrochemischer
Reaktion, die einen Abbau des Magnesiums zur Folge hat. Bei verbrauchter Magne-
siumanode ist der Korrosionsschutz des Speichers nicht mehr gewährleistet!
Folge: Durchrostung, Wasseraustritt. Deshalb muß sie alle 2 Jahre durch einen
konzessionierten Installateur kontrolliert und bei mehr als 2/3 Abnutzung erneuert
werden!
Zum Austausch der Anode muß der Speicher drucklos gemacht werden.
Kaltwasseranschluß schließen, Zirkulationspumpe abschalten und beliebigen Warm-
wasserhahn im Haus öffnen.
Beim Entleeren der Anlage kann heißes Wasser austreten und Verletzungen,
insbesondere Verbrühungen verursachen!
Bei eingebauter Fremdstromanode fällt keine Wartung an.
Nach Demontage des Flansches muss bei Wiedereinbau die Dichtung erneuert wer-
den, Anzugsdrehmoment der Muttern 20-25 Nm.
Achtung
Flansch
Störung Ursache Behebung
Undichtigkeit am Standspeicher Flansch undicht Schrauben mit 20-25 Nm
kreuzweise nachziehen;
Dichtung auswechseln
Rohranschlüsse undicht Neu eindichten
Aufheizzeit zu lang Heizwasser-Temperatur zu niedrig (am
Vorlauf Standspeicher messen, nicht am
Wärmeerzeuger)
Temperatur erhöhen (Regler einstellen)
Heizwassermenge zu klein (bewirkt große
Spreizung, d.h. Rücklauftemperatur zu
niedrig)
Größere Pumpe
Gegendruck von parallelen Heizungskreis-
lauf beachten
Heizschlange nicht entlüftet Bei abgeschalteter Pumpe mehrmals
entlüften
Verkalkung der Heizäche Heizäche entkalken
Brauchwassertemperatur zu gering Thermostat schaltet zu früh ab Thermostat nachstellen
Rücklauftemperatur zu niedrig (z.B. zu
große Spreizung)
Größere Ladepumpe
SEM-1
8 3043754_201508
Gerdewan Jacobs
Geschäftsführer Technik
Mainburg, 15.07.2015
KONFORMITÄTSERKLÄRUNG
(nach ISO/IEC 17050-1)
Nummer: 3043754
Aussteller: Wolf GmbH
Anschrift: Industriestraße 1, D-84048 Mainburg
Produkt: Solarspeicher SEM-1
Das oben beschriebene Produkt ist konform mit den Anforderungen der folgenden Dokumente:
DIN EN 12897:2006-09
Gemäß den Bestimmungen der folgenden Richtlinien
2009/125/EG (ErP-Richtlinie)
wird das Produkt wie folgt gekennzeichnet:
i. V. Klaus Grabmaier
Produktzulassung
Art.-Nr.: 3043754_201508
Wolf GmbH · Postfach 1380 · D-84048 Mainburg · Tel. +49-8751/74-0 · Fax +49-8751/741600 · Internet: www.wolf-heiztechnik.de
GB
Assembly Instructions
Solar tank SEM-1
SEM-1
10 3043754_201508
Technical Data .................................................................................................... 11
Pipework ............................................................................................................. 12
Installation / Assembly ........................................................................................ 13
Controller for charging pump ............................................................................. 14
Commissioning - Servicing ................................................................................. 15
Solar tank type SEM-1 made of steel S235JR with quality certication (with side ange).
Corrosion protection by double coat enamelling of the inner surface of the tank and heater
coil in accordance with DIN 4753, part 3. Additional corrosion protection with magnesium
protection anode. Can be used with all water conditions and in any pipe system.
Solar tank SEM-1
Solar tank type SEM-1
By operating the tank below 60°C, substantial energy savings can be achieved.
Ideal operating temperatures are between 50-60°C.
Heat loss and calcication is substantially reduced in this range.
Note
SEM-1
3043754_201508 11
Technical data
B
A
C
D
F
E
H
I
J
K
L
M
N
O
G
Tank Type SEM-1 500 750 1000
Tank contents litres Ltr. 500 750 935
Continuous storage capacity 80/60 - 10/45°C kW - Ltr./h 20-490 50-1200 50-1200
Capacity characteristic number (Heating) NL
60
6 13,5 18
Cold water connection A mm 99 220 220
Return solar circuit B mm 305 345 345
Tank sensor solar C mm 586 603 603
Supply solar D mm 865 920 975
Return heating E mm 985 1025 1340
Tank sensor of heating F mm 1160 1185 1500
Circulation G mm 1195 1290 1605
Supply heating H mm 1335 1475 1790
Hot water connection I mm 1451 1590 1940
Flange (bottom) J mm 335 384 384
Electrical auxiliary heating system K mm 949 970 1145
Thermometer L mm 1404 1460 1810
Total height M mm 1780 1850 2200
Diameter with thermal insulation N mm 850 1000 1000
Diameter without thermal insulation O mm - 800 800
Tilting measure with thermal insulation mm 1935 2030 2350
Primary - heating water bar/°C 10/110 10/110 10/110
Secondary - industrial water bar/°C 10/95 10/95 10/95
Internal anged diameter mm 114 114 114
Cold water connection G (IG) 1“ 1¼“ 1¼“
Heating supply / solar supply G (IG) 1“ 1¼“ 1¼“
Heating return / solar return G (IG) 1“ 1¼“ 1¼“
Circulation G (IG) ¾“ 1“ 1“
Hot water connection G (IG) 1“ 1¼“ 1¼“
Electrical auxiliary heating system G (IG) 1½“ 1½“ 1½“
Thermometer G (IG) ½“ ½“ ½“
Heating area (heating) 0,95 1,5 1,5
Heating area (solar) 1,8 2,1 2,4
Heat exchanger contents (heating) Ltr. 6,1 9,15 9,15
Heat exchanger contents (solar) Ltr. 11,5 13,5 14,5
Weight kg 182 290 350
* Vertical sensor position variable
** R (AG)
SEM-1
12 3043754_201508
Pipework
Connection solar tank SEM-1
to boiler and collector eld
Immersion sleeve thermo-
meter
Electrical auxiliary heating
system
Tank sensor of heating
Tank sensor solar
Hot water connection
Heating supply
Circulation
Heating return
Solar supply
Solar return
Cold water connection
according to DIN 1988
System diagram
À Collector eld
Á Air-vent bowl
 Collector sensor
à Solar module
Ä Solar pump assembly
Å Tank sensor solar
Æ Fill and drain valve
Ç Solar tank SEM-1
È Boiler
É Tank sensor of heating
SEM-1
3043754_201508 13
Installation / Assembly
Installation
The solar tank may be installed only in a frost-protected area. Otherwise, it must be
emptied in case of danger of frost.
Provide enough soil bearing capacity.
The solar tank must be installed in such a way that it can be emptied without dismantling.
Drain
Pressure reducer
The installation of a pressure reducing valve is generally recommended. The permissible
operating pressure of the solar tank on the industrial water side is 10 bar. If the mains
is operated with a higher pressure, a pressure reducer must be installed.
Exceeding the permissible operating pressure may cause leakages and destruc-
tion of the storage tank.
To reduce the ow noises within buildings, the pipe pressure should be set to approx.
3.5 bar.
Drinking water lter
Since washed-in foreign particles clog up ttings etc. and cause corrosion in the lines,
a drinking water lter must be installed in the cold water supply.
Attention
Hot/cold water connection
Solar tank
Install insulation before installing tubing.
The solar tank must be connected according to the pipework diagram on page 12. Only
a component-tested safety valve may be used. No shut-off system may be installed
between solar tank and safety valve.
If hot and cold water connections of the tank are provided with non-metallic tube
materials, teh tank has to be connected to earth.
The installation of splash guards or other narrowings into the connection pipe between
the solar tank and the safety valve is not permitted.
The minimum connection diameter of the safety valve must be DN20-¾".
The exit pipe must be at least equal in size to the safety valve outlet cross-section, may
have no more than 2 elbows and a maximum length of 2 m. If 3 elbows or a length up to
4 m are absolutely required, then the total exit pipe must be designed one nominal size
larger. The use of more than 3 elbows or a length over 4 m is not permitted. The exit
pipe must be installed with downward gradient. The drain pipe behind the drain funnel
must have at least twice the cross section of the valve entry. In the proximity of the exit
pipe of the safety valve, generally on the safety valve itself, a warning label must be
attached with the following text:
"During heating, water exits from exit pipe for safety reasons! Do not plug the
pipe!"
The selection of pipework material (i.e. connection ttings on site) has to be in accor-
dance with the rules of engineering and possible electro-chemical reactions have to
be taken into account (mixed component installation).
Attention
Attention
Attention
SEM-1
14 3043754_201508
Controller for charging pump
Insert electronic tank temperature sensor of the heating control into the upper immersion
sleeve for tank sensors of the solar tank and attach it with sensor holder. For tanks
with sensor channel insert sensor vertically downwards until stop position is reached.
Set desired tank temperature at the tank temperature controller of the heating control.
(max. 60°C).
Weather-dependent heating control
(heating control with integrated tank
temperature controller and tank tem-
perature sensor)
Electrical auxiliary heating
system E2 / E4,5 / E6
Electrical auxiliary heating
system
The rules and regulations of the VDE and the local utilities must be observed.
The connection must be performed by a licensed electrician.
Disconnect power before opening devices.
Unscrew cap from electrical auxiliary heating system and connect system to 230VAC
or 400 VAC power supply according to included instructions. Connecting wire must be
provided on site.
Electrical auxiliary heating system 2 kW/230 VAC, 4,5 kW/400 VAC, 6 kW/400 VAC
with built-in tank temperature controller and safety temperature limiter.
Screw electrical auxiliary heating system into the 1 ½" pipe coupling at the solar tank
and seal it.
SEM-1
3043754_201508 15
Commissioning - Servicing
Commissioning
The installation and initial commissioning may be performed only by a recognised
installation company.
Flush pipes and tank thoroughly after installation, ll tank with water. Open warm water
ow tap until water runs out and check safety valve by introducing air.
It is essential to ll and completely bleed tank before the rst start-up!
Attention: The max. operating pressure is 10 bar and must not be exceeded!
Exceeding the permissible operating pressure may cause leakages and destruc-
tion of the storage tank.
Operation with charging pump:
Set tank temperature controller SP1 to desired temperature (60°C max.).
When connecting an electronic tank sensor, the tank temperature is set at the boiler
control.
Operation with electrical auxiliary heating system E2 / E4,5 / E6
Set tank temperature controller of the heating control to 20°C.
Turn tank temperature controllers of the electrical auxiliary heating system to desired
temperature (60°C max).
Frost protection
In case of prolonged absence, the tank temperature controller can be turned completely
to the left (counter-clockwise). The frost protection function remains active.
After removing the ange the seal has to be replaced prior to reassembly, torque of
nuts 20-25 Nm.
Attention
Flange
Servicing
Magnesium anode
The unit must be checked by a professional company every 2 years.
In case of a built-in magnesium anode, the protective effect is based on an electroche-
mical reaction, which results in a decomposition of the magnesium. For this reason, it
must be checked every 2 years and replaced if necessary.
When changing the anode, the tank pressure must be relieved.
Close cold water connection, switch off circulating pump and open any hot water tap
in the house.
When using a built-in impressed-current anode, no servicing is required.
Fault Cause Remedy
Leakage at oor-standing Flange leaking hot water tank Re-tighten screws crosswise with 20-25
Nm;Replace seal
Pipe connections leaking Re-seal
Aufheizzeit zu lang Hot water temperature too low (measure
at the supply of oor- standing hot water
tank, not at the boiler)
Increase temperature
(adjust controller)
Heating water amount too small (causes
large spreading, i.e. return temperature
too low)
Larger pump
Observe back pressure of parallel heater
circuit
Heating coil does not bleed Bleed repeatedly with switched-off pump
Calcication of heating surface Decalcify heating surface
Industrial water temperature too low Thermostat switches off too early Reset thermostat
Return temperature too low
(e.g. excessive spreading)
Larger charging pump
Gerdewan Jacobs
Executive Board Engineering
Mainburg, 15.07.2015
Declaration of conformity
(acc. to ISO/IEC 17050-1)
No.: 3043754
Issued by: Wolf GmbH
Address: Industriestraße 1, D-84048 Mainburg
Product: Solar tank SEM-1
The product described above conforms to the requirements specied in the following documents:
DIN EN 12897:2006-09
In accordance with the following Directives:
2009/125/EG (ErP Directive)
This product is identied as follows:
i. V. Klaus Grabmaier
Product approval
Art.-Nr.: 3043754_201508
Wolf GmbH · Postfach 1380 · D-84048 Mainburg · Tel. +49-8751/74-0 · Fax +49-8751/741600 · Internet: www.wolf-heiztechnik.de
IT
Istruzioni di montaggio
Bollitore solare SEM-1
Pagina 17 - 24
SEM-1
18 3043754_201508
Dati tecnici ..................................................................................................................19
Intubamento................................................................................................................20
Installazione / Montaggio ............................................................................................21
Regolazione per la pompa di carico e riscaldamento .................................................22
Messa in funzione - Manutenzione .............................................................................23
Utilizzando il bollitore a temperature inferiori ai 60°C è possibile risparmiare una note-
vole quantità di energia.
Le temperature di esercizio ideali sono comprese tra i 50 e i 60°C.
Le dispersioni termiche e le incrostazioni di calcare si riducono notevolmente a queste
temperature.
Not a
Bollitore solare del tipo SEM-1 in acciaio S235JR con certicato di qualità (dotato di
angia laterale).
Protetto dalla corrosione mediante doppia smaltatura della parete interna del serbatoio
e serpentino di riscaldamento conforme a DIN 4753 parte 3. Ulteriore protezione dalla
corrosione grazie all’anodo al magnesio, utilizzabile con tutti i tipi di acqua e ogni tipo
di rete di alimentazione.
Bollitore solare SEM-1
Bollitore solare Tipo SEM-1
SEM-1
3043754_201508 19
Dati tecnici
B
A
C
D
F
E
H
I
J
K
L
M
N
O
G
Bollitore solare Tipo SEM-1 500 750 1000
Capacità bollitore Ltr. 500 750 935
Prelievo continuo bollitore 80/60 - 10/45°C kW - Ltr./h 20-490 50-1200 50-1200
Fattore di utilizzo (Riscaldamento) NL
60
6 13,5 18
Attacco acqua fredda A mm 99 220 220
Ritorno impianto solare B mm 305 345 345
Sensore impianto solare C mm 586 603 603
Mandata impianto solare D mm 865 920 975
Ritorno riscaldamento E mm 985 1025 1340
Sensore riscaldamento F mm 1160 1185 1500
Ricircolo G mm 1195 1290 1605
Mandata riscaldamento H mm 1335 1475 1790
Attacco acqua calda I mm 1451 1590 1940
Flangia (inferiore) J mm 335 384 384
Riscaldamento elettrico supplementare K mm 949 970 1145
Termometro L mm 1404 1460 1810
Altezza complessiva M mm 1780 1850 2200
Diametro con coibentazione N mm 850 1000 1000
Diametro senza coibentazione O mm - 800 800
Misura diagonale con coibentazione mm 1935 2030 2350
Acqua di riscaldamento primaria bar/°C 10/110 10/110 10/110
Acqua sanitaria secondaria bar/°C 10/95 10/95 10/95
Diametro interno angia mm 114 114 114
Attacco acqua fredda G (IG) 1“ 1¼“ 1¼“
Mandata riscaldamento/impianto solare G (IG) 1“ 1¼“ 1¼“
Ritorno riscaldamento/impianto solare G (IG) 1“ 1¼“ 1¼“
Ricircolo G (IG) ¾“ 1“ 1“
Attacco acqua calda G (IG) 1“ 1¼“ 1¼“
Riscaldamento elettrico supplementare G (IG) 1½“ 1½“ 1½“
Termometro G (IG) ½“ ½“ ½“
Supercie riscaldante (riscaldamento) 0,95 1,5 1,5
Supercie riscaldante (impianto solare) 1,8 2,1 2,4
Capacità scambiatore di calore (riscaldamento)
Ltr. 6,1 9,15 9,15
Capacità scambiatore di calore (impianto solare)
Ltr. 11,5 13,5 14,5
Peso kg 182 290 350
* La posizione verticale delle sonde è variabile
** R (AG)
SEM-1
20 3043754_201508
Intubamento
Allacciamento del bollitore solare
SEM-1 alla caldaia e al campo del
collettore
Sonda termometro
Riscaldamento elettrico sup-
plementare
Sensore riscaldamento
Sensore impianto solare
Attacco acqua calda
Mandata riscaldamento
Ricircolo
Ritorno riscaldamento
Mandata impianto solare
Ritorno impianto solare
Attacco acqua fredda
conforme a DIN 1988
Schema impianto
À Batteria collettori
Á Valvola di sato
 Sonda collettore
à Modulo solare
Ä Gruppo pompa solare
Å Sensore bollitore solare
Æ Rubinetto di carico e scarico
Ç Bollitore solare SEM-1
È Caldaia
É Sensore bollitore riscaldamento
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96

Wolf SEM-1 Assembly Instructions Manual

Typ
Assembly Instructions Manual

w innych językach