Novus NVIP-3SD-8200/30 Instrukcja obsługi

Kategoria
Kamery ochrony
Typ
Instrukcja obsługi
User s ma n ua l
(s h ort form )
NVIP-3SD-8200/30
NVIP-3SD-8200/30 Users manual (short form) ver.1.0
All rights reserved © AAT Holding S.A.
2
IMPORTANT SAFEGUARDS AND WARNINGS
EMC (2014/30/UE) and LVD (2014/35/UE) Directives
CE Marking
Our products are manufactured to comply with the requirements of the following directives and
national regulations implementing the directives:
- Electromagnetic compatibility EMC 2014/30/UE.
- Low voltage LVD 2014/35/EC with further amendment. The Directive applies
to electrical equipment designed for use with a voltage rating of between 50VAC and 1000VAC
as well as 75VDC and 1500VDC.
WEEE Directive 2012/19/UE
Information on Disposal for Users of Waste Electrical and Electronic Equipment
This appliance is marked according to the European Directive on Waste Electrical and
Electronic Equipment (2012/19/UE) and further amendments. By ensuring this product
is disposed of correctly, you will help to prevent potential negative consequences for the
environment and human health, which could otherwise be caused by inappropriate waste
handling of this product.
The symbol on the product, or the documents accompanying the product, indicates that this appliance
may not be treated as household waste. It shall be handed over to the applicable collection point for
used up electrical and electronic equipment for recycling purpose. For more information about
recycling of this product, please contact your local authorities, your household waste disposal service
or the shop where you purchased the product.
RoHS Directive 2011/65/UE
Information concerning the restriction of use of hazardous substances in electrical electronic
equipment.
Out of concern for human health protection and friendly environment, we assure that
our products falling under RoHS Directive regulations, regarding the restriction of the
use of hazardous substances in electrical and electronic equipment, have been designed
and manufactured in compliance with the above mentioned regulations.
Simultaneously, we claim that our products have been tested and do not contain hazardous substances
whose exceeding limits could have negative impact on human health or natural environment.
Information
The device, as a part of professional CCTV system used for surveillance and control, is not designed
for self installation in households by individuals without technical knowledge.
Excluding of responsibility in case of damaging data on a disk or other devices:
The manufacturer does not bear any responsibility in case of damaging or losing data on a disk or other
devices during device operation.
WARNING!
PRIOR TO UNDERTAKING ANY ACTION THAT IS NOT DESCRIBED FOR THE GIVEN
PRODUCT IN USERS MANUAL AND OTHER DOCUMENTS DELIVERED WITH THE
PRODUCT, OR IF IT DOES NOT ARISE FROM THE USUAL APPLICATION OF THE
PRODUCT, MANUFACTURER MUST BE CONTACTED UNDER THE RIGOR OF EXCLUDING
THE MANUFACTURERS RESPONSIBILITY FOR THE RESULTS OF SUCH AN ACTION.
NVIP-3SD-8200/30 (short form) ver.1.0
All rights reserved © AAT Holding S.A.
3
IMPORTANT SAFEGUARDS AND WARNINGS
WARNING!
THE KNOWLEDGE OF THIS MANUAL IS AN INDESPENSIBLE CONDITION OF A PROPER
DEVICE OPERATION. YOU ARE KINDLY REQUSTED TO FAMILIRIZE YOURSELF WITH THE
MANUAL PRIOR TO INSTALLATION AND FURTHER DEVICE OPERATION.
WARNING!
USER IS NOT ALLOWED TO DISASSEMBLE THE CASING AS THERE ARE NO USER-
SERVICEABLE PARTS INSIDE THIS UNIT. ONLY AUTHORIZED SERVICE PERSONNEL MAY
OPEN THE DEVICE.
INSTALLATION AND SERVICING SHOULD ONLY BE DONE BY QUALIFIED SERVICE
PERSONNEL AND SHOULD CONFORM TO ALL LOCAL REGULATIONS.
IMPORTANT SAFEGUARDS AND WARNINGS
1. Prior to undertaking any action please consult the following manual and read all the safety and operating
instructions before starting the device.
2. Please keep this manual for the lifespan of the device in case referring to the contents of this manual is necessary;
3. All the safety precautions referred to in this manual should be strictly followed, as they have a direct influence
on users safety and durability and reliability of the device;
4. All actions conducted by the servicemen and users must be accomplished in accordance with the users manual;
5. The device should be disconnected from power sources during maintenance procedures;
6. Usage of additional devices and components neither provided nor recommended by the producer is forbidden;
7. Mounting the device in places where proper ventilation cannot be provided (e. g. closed lockers etc.) is not
recommended since it may lead to heat build-up and damaging the device itself as a consequence;
8. Mounting the camera on unstable surface or using not recommended mounts is forbidden. Improperly mounted
camera may cause a fatal accident or may be seriously damaged itself. The camera must be mounted by qualified
personnel with proper authorization, in accordance with this users manual.
9. Device should be supplied only from a power sources whose parameters are in accordance with those specified
by the producer in the camera technical datasheet. Therefore, it is forbidden to supply the camera from a power
sources with unknown parameters, unstable or not meeting producers requirements;
10. Signal cables (conducting TV or / and telemetric signal) should be placed in a way excluding the possibility
of damaging them by accident. Special attention must be paid to cables getting from the camera and connecting
the power supply;
11. To avoid equipment damage, whole TV circuit should be equipped with properly made discharge, overload
and lightning protection devices. Usage of separating transformers is advised;
12. Electric installation supplying the device should be designed to meet the specifications given by the producer
in such a way that overloading is impossible;
13. User cannot repair or upgrade the equipment himself. All maintenance actions and repairs should be conducted
only by qualified service personnel;
14. Unplug the camera from the power source immediately and contact the proper maintenance department
when the following occurs:
Damages to the power cord or to the plug itself;
Liquids getting inside the device or exposure to strong mechanical shock;
Device behaves in a way not described in the manual and all adjustments approved by the manufacturer
and possible to apply by user himself, seem not to have any effect;
Camera or its casing is damaged;
Atypical behaviour of the camera components can be seen (heard).
15. In necessity of repairs attention to using only original replacement parts (with their parameters in accordance
with those specified by the producer) should be paid. Non-licensed service and non-genuine replacement parts
may cause fire or electric shock.
NVIP-3SD-8200/30 Users manual (short form) ver.1.0
All rights reserved © AAT Holding S.A.
4
FOREWORD INFORMATION
1. FOREWORD INFORMATION
1.1. General characteristic
Mechanical IR cut filter
IR operation capability - built-in IR LED illuminator
Imager resolution: 3 megapixels
Min. Illumination: from 0.007 lx/F1.6 - B/W mode, 0.07 lx/F=1.6 color mode
Motor-zoom lens, AI and AF function
Wide Dynamic Range (WDR 120dB) for enhanced image quality in diverse light conditions
Automatic DSS function
Object tracking (Auto Tracking)
12 tours (max. 32 presets each)
12 auto-scan functions
6 patterns
393 preset commands
Privacy zones: 4, type color
Optical zoom: up to 30x
7 alarm inputs & 2 alarm relay outputs (NO/NC)
Auto-Flipfunction allows the tilt to rotate 180° and reposition itself for continuous viewing of a
moving object directly beneath the dome
Compression: H.264, H264+, H.265, H265+, M-JPEG
Bidirectional audio transmission
Video processing resolution: up to 2048 x 1536
RTP/RTSP protocol support for video & audio transmission
Triple stream mode: compression, resolution, speed and quality defined individually for each video
stream
Built-in web server: camera configuration through the website
Diverse definition of system reactions to alarm events: e-mail with attachment, alarm output
trigger, PTZ function activation, save on FTP
PTZ control directly from the website and NMS (NOVUS MANAGEMENT SYSTEM)
Network protocols support: ONVIF Profile S/Q, HTTP, TCP/IP, IPv4, IPv4/v6, UDP, HTTPS,
FTP, DHCP, DNS, DDNS, NTP, RTSP, RTP, UPnP, SNMP, PPPoE, RTCP
Software: NMS for video recording, live monitoring, playback and remote IP devices
administration
IP 66
Housing and wall mount bracket in-set included
Power supply: 24 VAC, High PoE (60W) - compatible with NV-8000PS/HP High PoE Injector
Information:
Depending on the type of recorder/registration system, the range of features and options may vary. Full
list of camera functionality available from a given type of recorder is included in the Compatibility
Table available on www.novuscctv.com/en
NVIP-3SD-8200/30 (short form) ver.1.0
All rights reserved © AAT Holding S.A.
5
FOREWORD INFORMATION
1.3 Technical Specification
Image
Image Sensor 3 MPX CMOS sensor 1/2.8” SONY Exmor R STARVIS
Number of Eecve Pixels 2065 (H) x 1553 (V)
Min. Illuminaon
0.07 lx/F1.6 - color mode,
0.007 lx/F1.6 - B/W mode,
0 lx (IR on) - B/W mode
S/N Rao > 55 dB (AGC o)
Electronic Shuer auto/manual: 1/5 s ~ 1/20000 s
Digital Slow Shuer (DSS) up to 1/5 s
Wide Dynamic Range (WDR) yes (double scan sensor), 120dB
Digital Image Stabilizaon (DIS) yes
Digital Noise Reducon (DNR) 2D, 3D
Defog Funcon (F-DNR) yes
Highlight Compensaon (HLC) yes
Back Light Compensaon (BLC) yes
Lens
Opcal Zoom 30x
Lens Type motor-zoom, auto-iris funcon, f=4.5 ~ 135 mm/F1.6 ~ F4.4
Auto-focus connuous, zoom trigger, manual trigger
Day/Night
Switching Type mechanical IR cut lter
Switching Mode auto, manual, me
Switching Level Adjustment yes
Switching Delay 0 ~ 180 s
Switching Schedule yes
Visible Light Sensor yes
Network
Stream Resoluon
2048 x 1536 (QXGA), 1920 x 1080 (Full HD), 1280 x 720 (HD), 704 x 576,
704 x 480, 640 x 480 (VGA), 640 x 360, 352 x 288 (CIF), 352 x 240,
320 x 240 (QVGA)
Frame Rate 30 fps for 2048 x 1536 (QXGA) and lower resoluons
Mulstreaming Mode 3 streams
Video/Audio Compression H.264, H.264+, H.265, H.265+, MJPEG/G.711, RAW_PCM
Number of Simultaneous Connecons max. 8
Bandwidth 30 Mb/s in total
Network Protocols Support
HTTP, TCP/IP, IPv4, IPv4/v6, UDP, HTTPS, FTP, DHCP, DNS, DDNS, NTP, RTSP,
RTP, UPnP, SNMP, PPPoE, RTCP
ONVIF Protocol Support Prole S/Q
Camera Conguraon
from Internet Explorer browser
languages: Polish, English, Russian, and others
Compable Soware NMS
NVIP-3SD-8200/30 Users manual (short form) ver.1.0
All rights reserved © AAT Holding S.A.
6
FOREWORD INFORMATION
*Inactive when Auto Tracking enabled
PTZ
Preset Commands 393
Tours 12 (up to 32 presets per tour)
Auto-Scans 12
Paerns 6
Tilt/Pan Range 0° ~ 98°/360° (connuous)
Pan/Tilt Speed up to 180°/s (proporonal to zoom)
Preset Speed up to 180°/s
Protocols Pelco-D
Other funcons
Privacy Zones 4 video mask type: single color*
Moon Detecon yes
Region of interest (ROI) 8
Video Content Analysis (VCA) Auto Tracking, zone entrance detecon and object tracking
Image Processing 180˚ image rotaon, sharpening, mirror eect
System Reacon to Alarm Events e-mail with aachment, saving le on FTP server, alarm output acvaon, PTZ
IR LED
LED Number 10
Range up to 200 m (depends on current opcal zoom value)
Angle up to 45° (depends on current opcal zoom value)
Interfaces
Video Output BNC, 1.0 Vp-p, 75 Ohm - maintenance only
Audio Input/Output 1 x RCA/1 x RCA
Alarm Input/Output 7 (NO/NC)/2 relay type
RS-485 yes
Network Interface 1 x Ethernet - RJ-45 interface, 10/100 Mbit/s
Installaon parameters
Dimensions (mm) 226 (Ф) x 363 (H) with bracket: 226 (W) x 425 (H) x 345 (L)
Weight 5.1 kg with bracket: 6.1 kg
Degree of Protecon IP 66 (details in the users manual)
Enclosure
aluminium, white, in set: outdoor housing (integrated with the camera),
wall mount bracket
Power Supply 24 VAC, High PoE (60W) - compable with NV-8000PS/HP High PoE Injector
Surge protecon TVS 6000 V
Power Consumpon 18 W, 46 W (IR and heater on)
Operang Temperature -30°C ~ 60°C
Built-in Heater/Fan yes/yes
NVIP-3SD-8200/30 (short form) ver.1.0
All rights reserved © AAT Holding S.A.
7
FOREWORD INFORMATION
1.3. Camera dimensions (in millimeters)
345
207
363
425
Ф226
NVIP-3SD-8200/30 Users manual (short form) ver.1.0
All rights reserved © AAT Holding S.A.
8
1.4. Package contents
After you open the package make sure that the following elements are inside:
If any of this elements has been damaged or missing during transport, pack all the elements back into
the original box and contact your supplier for further assistance.
CAUTION!
If the device was brought from a location with lower temperature, please wait until it reaches
the temperature of location it is currently in. Turning the device on immediately after bringing it
from a location with lower ambient temperature is forbidden, as the condensing water vapour
may cause short-circuits and damage the device as a result.
Before starting the device familiarize yourself with the description and the role of particular
inputs, outputs and adjusting elements that the device is equipped with.
FOREWORD INFORMATION
Novus IP PTZ camera NVIP-2DN5022SD/IRH-2 1 pcs
Wall bracket 1 pcs
Power adapter AC230V/AC24V 1 pcs
Slotted screwdriver Φ2.5 mm 1 pcs
White glove 1 pcs
Connection terminal 2Pin 2 pcs
Bolts: PM 3X 12mm 3 pcs
Users manual (short form) 1 pcs
NVIP-3SD-8200/30 (short form) ver.1.0
All rights reserved © AAT Holding S.A.
9
2. START-UP AND INITIAL IP CAMERA CONFIGURATION
2.1. Description of connectors
1. Alarm Connectors 5. Power Connector (24VAC)
2. Audio output 6. Ground
3. Audio input 7. RJ-45 Connector
4. BNC—analog output 8. RS-485 Connectors
START-UP AND INITIAL CAMERA CONFIGURATION
1
2
3
5
7
4
8
6
NVIP-3SD-8200/30 Users manual (short form) ver.1.0
All rights reserved © AAT Holding S.A.
10
2.2. Connecting power supply to the camera.
Camera can be supplied using external power supply unit corresponding with the camera parameters.
When selecting the power supply, also take into account the power consumption of the heater.
CAUTION!
In order to provide protection against voltage surges/lightning strikes, usage of appropriate
surge protectors is advised. Any damages resulting from surges are not eligible for service
repairs.
CAUTION!
It is forbidden to use as the camera power source PoE equipment (adapters, etc.)
not compatible with IEEE 802.3af standard (items called passive PoE power supply”). If use a
PoE technology to power the camera, use a High PoE NV-8000PS / HP power injector.
d
Damages that results from the usage of improper power supply source are not covered
by the warranty.
START-UP AND INITIAL CAMERA CONFIGURATION
No Color Funkction Describe
1
brown Alarm output 1
Two alarm outputs, configurable: NC, NO or pulse
(relay, 12VDC, 2.5A max.)
brown-black Alarm output 1 (COM)
red Alarm output 2
red-black Alarm output 2 (COM)
orange Alarm input 1
Seven alarm inputs, configurable: NC or NO
orange-black Alarm input 2
yellow Alarm input 3
yellow-black Alarm input 4
green Alarm input 5
green-black Alarm input 6
blue Alarm input 7
blue-black Alarm input COM
2 red Audio Output (RCA)
AUDIO OUTPUT:
For connecting external audio devices such as
speakers with an amplifier
3 white Audio Input (RCA)
AUDIO INPUT:
For connecting external audio devices such as
a microphone with an amplifier
4 - BNC connector Analog maintance signal
5
red
Power Supply 24VAC
AC24-IN-POWER:
Power supply cord AC 24V
black
6 yellow uziemienie
GNDEARTH:
Ground wire
7 - Ethernet (RJ-45)
Ethernet connector
8
green RS-485 + connector
External keyboard connectors
yellow RS-485 - connector
NVIP-3SD-8200/30 (short form) ver.1.0
All rights reserved © AAT Holding S.A.
11
2.3. Mounting the camera
In order to obtain declared degree of protection please seal the mounting place additionally with
appropriate sealing mass, paying special attention to mounting holes.
CAUTION!
Declared degree of protection of the camera concerns to it case and does not include the
possibility penetration of moisture through connecting cables. Securing cables is a responsibility
of person who install the camera. The manufacturer is not responsible for any injury, damage of
the camera caused by any failure above-mentioned duty, what also means they are not subject to
warranty repairs.
CAUTION!
Due to safety reasons, maximum load capacity of surface shouldnt be less than 25kg.
In order to successfully mount a camera, please follow the procedure below:
Put the bracket to the wall in a desired mounting place (with cable hole). Taking the brackets
base screw holes as a pattern, mark future drilling holes for screws using a punch.
Drill 4 holes in accordance with previously done markings, insert the expansion plugs into the
holes.
Screw the muff into the bracket and lock the muff with the locking screw.
Thread the wires through the hole in the muff of bracket.
Attach the camera to the muff in bracket, tighten the three bolts to fix the bracket and camera
and then hook the safety cord in the bracket
By using the description of the terminals from the previous chapter and the appropriate
accessories, connect required signal and power supply cables.
WARNING!
Connection the power cable to the camera must be performed after disconnecting the power
source. Power can be on only after the camera is fully mounted.
Put the excess cable back into the bracket.
Screw on the camera with the bracket to the wall.
After the above steps the camera is ready to work
START-UP AND INITIAL CAMERA CONFIGURATION
NVIP-3SD-8200/30 Users manual (short form) ver.1.0
All rights reserved © AAT Holding S.A.
12
2.4. Starting the IP camera
To run NOVUS IP camera connect 24 VAC power supply or NV-8000PS/HP High PoE Injector.
Initialization process takes about 1 minute. Then you can proceed to connect to the camera via web
browser.
The recommended way to start an IP camera and perform its configuration is a connection to the PC
via the network switch which is not connected to other devices.
To obtain further information about network configuration parameters (IP address, gateway, network
mask, etc.) please contact your network administrator.
Connection using external power supply and network switch
Connection using the network switch and power supply of the camera via the
High PoE NV-8000PS / HP power supply
START-UP AND INITIAL CAMERA CONFIGURATION
IP Camera
Network transmission
Network
transmission
Network Switch
Computer
Power supply
Network
transmission
Network
transmission
Power
and Network
Network
switch
Computer
IP Camera
NV-8000PS/HP
NVIP-3SD-8200/30 (short form) ver.1.0
All rights reserved © AAT Holding S.A.
13
Connection using external power supply, directly to the computer.
2.5. Initial configuration via the web browser
The default network settings for Novus cameras are :
1. IP address- 192.168.1.200
2. Network mask - 255.255.255.0
3. Gateway - 192.168.1.1
4. User name - root
5. Password - pass
Knowing the cameras IP address set PC IP address appropriately, so the two devices can operate in
one network subnet ( e.g. for IP 192.168.1.1, appropriate address for the camera is from range
192.168.1.2 to 192.168.1.254, for example 192.168.1.60). It is not allowed to set the same addresses
for camera and PC computer
You can either set a network configuration (IP address, gateway, net mask, etc.) of NOVUS IP camera
yourself or select DHCP mode (DHCP server is required in this method in target network) by using
web browser or by NMS software. When you use DHCP server check IP address lease and its linking
with camera MAC address to avoid changing or losing IP address during device operation or network/
DHCP server breakdown. You have to remember to use a new camera IP address after changing
network parameters.
After network setting configuration has been done, the camera can be connected to a target network.
START-UP AND INITIAL CAMERA CONFIGURATION
IP Camera
Network transmission - cross over cable
Computer
Power supply
NVIP-3SD-8200/30 Users manual (short form) ver.1.0
All rights reserved © AAT Holding S.A.
14
2.6. Security recommendations for network architecture and configuration
WARNING!
Below are shown security recommendations for network architecture and configuration
of CCTV systems that are connected to the Internet to reduce the risk
of unauthorized interference with the system by a third party.
1. Absolutely change the default passwords and user names (if the device gives this possibility) of
all applied network devices (recorders, cameras, routers, network switches, etc.) to the
severely complexity password. Use lowercase and uppercase letters, numbers, and special characters
if there is such possibility.
2. Depending on the available functionality in the order to restrict access to the used network devices
at the administrator account level, it is recommended to configure the users accounts accordingly.
3. Do not use DMZ function (Demilitarized zone) in your router. Using that function you open the
access to recorder system from the Internet on all ports, which gives possibility for an unauthorized
interference with the system.
Instead of DMZ use port forwarding redirect only the ports which are necessary for the performance
of the connection (detailed information about ports of communication in different models
of recorders, cameras, etc. can be found in the operating instructions).
4. Use routers with firewall function and make sure it is enabled and properly configured.
5. It is recommended to change the default network communication port numbers of used devices
if there is such possibility.
6. If used network devices has a UPnP feature and it is not used, turn it off.
7. If used network devices has a P2P feature and it is not used, turn it off.
8. If used network devices support HTTPS protocol for connection, it is recommended to use it.
9. If used network devices support IP filtering for authorized connections function, it is recommended
to use it.
10. If used recorder has two network interfaces it is recommended to use both of them to physically
separate network for cameras and network for Internet connection. The only device in the system,
accessible from Internet will be recorder - there will be no physically access directly to any camera.
START-UP AND INITIAL CAMERA CONFIGURATION
NVIP-3SD-8200/30 (short form) ver.1.0
All rights reserved © AAT Holding S.A.
15
NETWORK CONNECTION VIA WEB BROWSER
3. NETWORK CONNECTION VIA WEB BROSWER
3.1. Recommended PC specification for web browser connections
Requirements below apply to connection with an IP camera, assuming image display in 2048 x 1536
resolution and 30 fps speed.
1. CPU Intel i5 3 GHz or faster
2. RAM Memory min. 4 GB
3. VGA card (any displaying Nvidia GeForce 512MB Ram memory)
4. OS Windows 7 / 8 / 10
5. Network card 100/1000 Mb/s
3.2. Connection with IP camera via web browser
CAUTION!:
To maintain correct operation as snapshot or video recording, must enable the browser as an
administrator, also to maintain correct operation as playback, must add IP camera address to
Compatibility View in browser settings.
Enter camera IP address in the web browser address bar. If IP address is correct user login window will
be displayed:
Default user is root and default password is pass.
In the Language box you can change the display language. The default language is English.
For safety reasons, it is recommended to change default user name and password.
NVIP-3SD-8200/30 Users manual (short form) ver.1.0
All rights reserved © AAT Holding S.A.
16
If first time running the camera, you will see screen as below.
To correctly camera working, you need a plugin, download and install it as below.
Click Download and setup and follow the prompts.
NETWORK CONNECTION VIA WEB BROWSER
Download and setup
Download and setup
NVIP-3SD-8200/30 (short form) ver.1.0
All rights reserved © AAT Holding S.A.
17
Click Install button
After installation, click Finished button
CAUTION: In Windows Vista/7/8/10 the ActiveX applet may be blocked by Windows
Defender or User account control. In such case you should allow to run this applet, or simply
disable these functions.
CAUTION: If the installation fails, changing security settings for the IE browser is required.
In order to do that, please choose: Tools > Internet options > Security tab > Custom level
and enable the function Download of unsigned ActiveX controls.
NETWORK CONNECTION VIA WEB BROWSER
NVIP-3SD-8200/30 Users manual (short form) ver.1.0
All rights reserved © AAT Holding S.A.
18
WWW INTERFACE - WORKING WITH CAMERA
4. WWW INTERFACE - WORKING WITH IP CAMERA
4.1. Displaying live video
1. Camera menu:
Live Video - opens the camera live video
Playback - function inactive
Configuration - opens the camera configuration menu
2. Change Password and Sign out buttons - are used to change the password and log off the
current user.
3. Live video preview
4. Stream information
5. Live video menu
Selection of stream preview
PTZ button - turn on PTZ window
3D button - turn on/off 3D control
Video button - turn on/off camera preview output
Live / Smooth Button- turn-on smooth preview option
Audio button - turn on/off audio output
Interphone button - turn on/off audio input and output
Sensor button - turn on sensor configuration menu
Snapshot button - make a preview snapshot
VCA button - turn on/off VCA graphics on the screen
1.
3.
4.
5.
2.
NVIP-3SD-8200/30 (short form) ver.1.0
All rights reserved © AAT Holding S.A.
19
2. Video Parameter
Stream - Stream ID (choose one from available streams)
Bite Rate Type - Information about bit rate type
Bit Rate (kbps) - Information about bit rate
I Frame Interval - Information about I frame interval
Quality - Information about quality
USE TIME STAMP - Video buffer (increases delay when enabled, maximum delay is 5s)
NOTICE: USE TIME STAMP function will not be available when using Flash instead of ActiveX.
3. PTZ Control Panel
PTZ Configure:
Preset - Programming, deleting, and recalling presets
Track - Programming, deleting, and recalling tracks
Speed - Setting speed of movement
3D Position - Turns on/off control using the mouse
North - Setting orientation of the camera
Timer - Setting schedules
PTZ Control:
Arrow keys - Controlling the movement of the camera: up/down, right/left
Homekey - Function unavailable
Zoom - Zoom control
Focus - Focus control
Iris - Function unavailable
Brush - Function unavailable
On/Off IR - Function unavailable
4. Menu bar
Change Password - Change users password
NOTICE: Default password "pass" can be restored only after restoring default settings of the camera)
Sign Out - Log out from camera
5. Video Control
Camera - Default number of the camera is 1.
Video - Turn on/off video
Audio - Turn on/off audio
Interphone - Turn on/off Interphone
NOTICE: Audio and Interphone functions will not be available when using Flash instead of Activex.
RESTORING DEFAULTS
4.2 Adding a site to the Compatibility View list
1. Open Internet Explorer, select the Tools button and then select Compatibility View settings (1).
2. Under Add this website, enter the URL of the site you want to add to the list (2), and then select
Add (3).
5. RESTORING FACTORY DEFAULTS
Novus IP cameras allow to restore defaults via www menu.
5.1. Software restoration of factory settings the IP camera
User can restore default settings of the IP camera included the network settings (optional). To restore to
default settings go to: Maintenance -> Device Restart tab. Process of restoring takes about two
minutes.
1.
2.
3.
2019-04-30 JZ MK MM ver. 1.0
AAT Holding S.A.
ul. Puławska 431, 02-801 Warszawa
tel.: (22) 546 0 700, fax: (22) 546 0 719
www.novuscctv.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40

Novus NVIP-3SD-8200/30 Instrukcja obsługi

Kategoria
Kamery ochrony
Typ
Instrukcja obsługi

w innych językach