Operation safety requirements:
- By setting in motion or maintenance works by the lter and in case of any other works in the reservoir, unplug all
electric devices placed in the aquarium.
- The lter is designed for aquariums only and for use in rooms only!
- The unit may operate at the water temperature not exceeding 35°C!
- Before each putting into operation, check the lter and the power supply cord!.
- It is forbidden to make any repairs or replacements of the power supply cord!
- The use of the lter without water is not allowed.
- Install the unit following the instruction.
In case of a damage to the power supply cord, the unit should be scrapped!
Danger of a risk to life!
Filter characteristics:
- Non-complicated service, easy maintenance
- Small dimensions, low noise level
- Mechanical and biological water cleaning
- Made to RP and UE safety standards
- High ltration efciency thanks to the use of ltrating unwoven bre.
- Perfect oxygen enrichment thanks to the air cap.
- Smooth adjustment of water ow without a need to remove the pump from the aquarium.
- 1.5 m long power supply cord.
Mounting:
1. Install the air-outlet hose on the air cap. Set the aeration regulator (pic.1) on the other side of the hose.
2. Slip the prepared cap on the impeller tank outlet (pic. 2)
3. Install the lter hanger on the aquarium glass with the vacuum cups and set the lter on the guide bars. The
whole lter construction should be placed below the water level in aquarium (pic. 3).
4. Plug the lter in.
5. Set the water ow by moving the regulator and adjust it to the needs of your aquarium (number of sh, reservoir
size) (pic. 5).
The dry operation (without water) of the lter is not allowed!!! During operation, the lter should be fully immersed
in water while the aeration regulator should fully protrude above the water mirror.
Note !!! Due to evaporation, the water level in the aquarium sinks!
Inspection survey and maintenance:
To maintain the high efciency of the lter, it is recommended to perform, on a regular basis, the cleaning of the
lter, the rotor and its chamber. To this aim, never use detergents (soap, dish washing liquids, etc.) and solvents;
the residue of these means left in the lter may result in diseases and sh mortality.
Note !!! Before performing any work in the aquarium or on the lter, switch off without fail the lter by removing the
mains plug from the socket.
Filtrating inset cleaning:
1. Disconnect (unplug) the device (pic. 6) !
2. Take the lter out of the water (pic. 7).
3. Disconnect the engine from the lter (pic. 8).
4. Take the container cover off (pic. 9).
5. Remove the ltrating inset and rinse it under owing cool water (pic. 10).
6. Put the lter together in reversed order.
In case of any disturbances in the motor operation (heavily working motor), the rotor and its chamber should be
cleaned.
Impeller and impeller tank cleaning:
1. Disconnect (unplug) the device!
2. Take the lter out of the water.
3. Take the lter container off the engine body.
4. Turn the impeller tank so it will be positioned +/- 90° and take the impeller cover off (pic. 11).
D
GUARANTEE TERMS AND CONDITIONS.
AQUA-SZUT Sp. z o.o. with permanent establishment ul. Opolska 11/19 in Wrocław (52-010) is offering to the buyer a guarantee of correct
operation of the device, for which this guarantee card has been issued, under the condition that it is used according to the intended use and the
rules specied in the User’s Manual delivered to the Buyer together with this item. The unit is covered by 24-month guarantee (from the date
of purchase). and it includes the products bought in any part of Europe. The guarantee excludes defects resulting from improper operation. It
is conned to the unit itself, covers material and workmanship defects, but excludes any consequential damages. The guarantee is effected by
repair or replacing the defective unit. To effect guarantee repair, please deliver the unit with its guarantee card to the retail outlet. The repair will
be completed within 14 days of delivering the unit and raising the claim. The guarantee for the sold consumer goods does not exclude, limit or
suspend the rights of the buyer following from goods contrary to the agreement.
TURBO (N) - INNENFILTER
Betriebstiefe:
- minimal: Oberkante des Motorkörpers unterhalb des Wasserspiegels
- maximal: der gesamte Luftregler oberhalb des Wasserspiegels
Benutzungshinweise:
- Der Innenlter dient zur Wassereinigung in Aquarien und gibt zusätzlich die Möglichkeit, Wasser mit Sauerstoff
anzureichern.
- Vor der Installation und Inbetriebnahme die Bedienungs- und Montageanleitung gründlich durchlesen!
- Die Nutzungs-, Montage und Sicherheitshinweise unbedingt beachten!
Arbeitssicherheitsbedingungen:
- Bei der Inbetriebnahme und bei der Wartung des Filters und bei anderen Arbeiten im Wasserbehälter sollen alle
elektrische Vorrichtungen, die sich im Aquarium benden, von der Stromersorgung getrennt werden.
- Der Filter ist ausschließlich für Aquarien und nur in Innenräumen vorgesehen!
- Das Gerät ist ausschließlich für Wassertemperaturen unter 35 °C!
- Vor jeder Inbetriebnahme den Filter und das Netzkabel überprüfen!
- Es ist verboten, jegliche Reparaturen an den Gerät bzw. an dem Netzkabel vorzunehmen!
- Es ist verboten, den Filter trocken (außerhalb von Wasser) zu betreiben.
- Das Gerät gemäß der Anleitung installieren.
Bei einer Beschädigung des Netzkabels ist das Gerät zu entsorgen! Lebensgefahr!
Filtermerkmale:
- einfache Bedingung und Wartung
- kompakt, niedriger Lärmpegel
- mechanische und biologische Wasserreinigung
- entspricht den RP- und EU-Sicherheitsnormen
- Hohe Filtrierungsleistungsfähigkeit dank dem Gebrauch des Filtrationsvliesstoffes.
- Perfekte Sauerstoffaufbereitung dank dem Lüftungsansatz.
- stufenlose Regelung des Wasserdurchusses mit Hilfe des Reglers , ohne dass die Pumpe aus dem Aquarium
5. Take the impeller out of the tank and rinse it carefully under owing water, remove the mud from the impeller.
Rinse also the impeller tank and the regulator.
6. Put the lter together in reversed order.
Disassembly and withdrawal from use:
„The producer of waste” - that is the user of the lter, at the moment of liquidating the product or replacing the
worn- out parts, shall take the following actions:
- parts that are good for further use shall be subjected to reclaiming or stored,
- rubber, plastic elements, etc. shall be delivered to the recycling centers,
or handled according to the local prescriptions on treating metallic, inorganic, organic or mixed waste.
The non-observance of these instructions excludes the potentiality of recognizing warranty claims.
NOTE: The manufacturer, that is the company AQUA-SZUT Sp. z o.o. having its ofces in Wroclaw, reserves the
right to modify the engineering parameters of the unit.