AMP Lighting RenaissancePro ADL-2011-4-B-BZ Installation & Maintenance Manual

Typ
Installation & Maintenance Manual
INSTALLATION & MAINTENANCE GUIDE
Help Hotline:
1-813-978-3900 • Mon-Fri 9am-6pm (EST)
www.amplighting.com
AMP
®
Low Voltage Landscape Lighting
AMP
®
RenaissancePro Deck Light
ADL-2011-4-B-BZ
AMP
®
RenaissancePro Deck Light
ADL-2011-4-B-BZ
INSTALLATION & MAINTENANCE GUIDE
www.amplighting.com
–2–
Important Safety Instructions: Read Before Installation
!
This luminaire is intended for installation in accordance with local codes
and the National Electric Code (NEC). Failure to adhere to these codes and
instructions may result in serious injury, property damage and void the
warranty.
These instructions do not intend to cover all variations in installation,
operation maintenance or mounting situations.
1. Make sure the power is turned OFF before installing or servicing this
luminaire.
2. WARNING: risk of electrical shock. Install all luminaires 10 feet (3.05M)
or more from pool, spa or fountain.
3. This luminaire is intended to be used only with a power supply
(transformer) rated maximum of 300 watts (25 AMPS) at 15 volts.
4. Wiring connections must be made with UL listed wire connectors that are
suitable for outdoor use.
5. Position the low voltage wire and wire connector so that it is located
within 6 inches (15.2 cm) from a building structure, a luminaire or
tting.
6. The main low voltage cable is intended for shallow burial - less than 6
inches (152 mm).
7. If additional lengths of low voltage cable are required, please contact
www.amplighting.com or call 1-813-978-3900.
Important Safety Instructions
!
INSTRUCTIONS PERTAINING TO A RISK OF FIRE, OR INJURY TO PERSONS
Lighted lamp is HOT!
WARNING – To reduce the risk of FIRE OR INJURY TO PERSONS.
1. Turn off/unplug and allow to cool before replacing lamp.
2. Lamp gets HOT quickly! Contact only switch/plug when turning on.
3. Do not touch the hot lens, guard or enclosure.
4. Keep lamp away from materials that may burn.
5. Do not touch lamp at any time. Use a soft cloth. Oil from skin may dam-
age lamp.
6. Do not operate the luminaire tting with a missing or damaged shield.
SAVE THESE INSTRUCTIONS
[email protected] • 813.978.3900
Product Dimensions
–3–
Package Contents
A. (1) Fixture
B. (2) Lock Screws
4.25”
2.75”
3.5”
2”
ProTip for Hiding Lead Wire
Determine the location for the xture. Drill a hole straight through the
desired mounting location and run the lead wire out the backside of
the location so that the wires are not visible from the front side. Use a
matching trim piece and cut a groove in the back of trim. Cover the lead
wires with the matching trim piece.
ProTip for Hiding Splice Connections
All xtures come with 4’ of lead wire enabling you to hide the splice
connections out of sight. If you must make a splice connection in view, use
an inline heat shrink style connection that is less visible than traditional
twist caps.
Parts Required
A. (1) Lamp
INSTALLATION & MAINTENANCE GUIDE
–4–
www.amplighting.com
–4–
Remove Face Cover
1
AMP
®
RenaissancePro Deck Light
ADL-2011-4-B-BZ
Face Cover
Fixture Body
Rotate
Rotate the face cover until it
stops and then lift the cover
straight off.
Note: The rst time it may be
difcult because the xture
has a very tight o-ring seal and
a grease sealant for moisture
protection.
Install Fixture Body
2
Fixture Body
Lock Screw
Wall Anchor
(optional)
Hole
Attach the xture body to your
desired location and secure with lock
screws.
Note: Wall anchors may be required
for certain installation conditions
(e.g. Brick walls, Concrete Walls,
etc.). Mark on the wall using holes
on the xture body to drill holes for
your wall anchors. Remove base and
drill proper holes in the wall, then
insert wall anchors.
Install Lamp
3
Insert lamp with the correct
wattage and type marked on
xture label and push into place.
CAUTION: Do not exceed
maximum wattage marked on
luminaire label.
Lamp
Socket
[email protected] • 813.978.3900
–5–
INSTALLATION & MAINTENANCE GUIDE
Install Face Cover
4
Wire Connections
5
AMP
®
RenaissancePro Deck Light
ADL-2011-4-B-BZ
Fixture Body
Face Cover
Push face cover back onto the
xture body aligned with the gaps
in the xture body. Once the face
cover is ush with the xture body,
rotate the face cover until it stops
and locks into place.
Fixture
Wire
Connectors
Main Supply Cable
Pigtail
Strip both leads from luminaire
pigtail. Using two wire connectors
(sold separately), connect leads
from luminaire to main supply cable
leads.
Install/Replace Lamp
Rotate the face cover and remove it to expose the lamp. Replace it with the
correct wattage and type marked on the xture label. Then, reinstall the
face cover.
IMPORTANT: Halogen bulbs must be protected from moisture and dust at all
times. Always reinstall the face cover when removed.
INSTALLATION & MAINTENANCE GUIDE
–6–
www.amplighting.com
–6–
AMP
®
RenaissancePro Deck Light
ADL-2011-4-B-BZ
Decorative Arms
Install Decorative Arms
Decorative arms are sold as
additional options for this deck light.
Please read the following steps for
installation of the decorative arms.
5.5”
3.5”
Attach the decorative arms on the
top or bottom of the xture body
and secure with lock screws. Multiple
decorative arms can be added going
up or down to create your own unique
look.
Note: Wall anchors may be required
for certain installation conditions (e.g.
Brick walls, Concrete Walls, etc.).
Mark on the wall using holes on the
xture body to drill holes for your wall
anchors. Remove base and drill proper
holes in the wall, then insert wall
anchors.
Fixture
Body
Decorative
Arms
Decorative
Arms
Hole
Hole
Decorative
Arms
Lock Screw
Wall Anchor
(optional)
Hole
–6––6–
[email protected] • 813.978.3900
–7–
IS-ADL-2011-4-B-BZ-ver1.pdf
Specications and product details subject to change without notice.
© Copyright 2019, AMP
®
Lighting, Lutz FL USA 33549 • All rights reserved.
[email protected] • 813.978.3900
Help Hotline:
1-813-978-3900 • Mon-Fri 9am-6pm (EST)
www.amplighting.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

AMP Lighting RenaissancePro ADL-2011-4-B-BZ Installation & Maintenance Manual

Typ
Installation & Maintenance Manual