AMP Lighting HydraPro AUL-8001-25-B-BZ Instrukcja instalacji

Kategoria
Ściana
Typ
Instrukcja instalacji

Ten podręcznik jest również odpowiedni dla

INSTALLATION & MAINTENANCE GUIDE
Help Hotline:
1-813-978-3900 • Mon-Fri 9am-6pm (EST)
www.amplighting.com
AMP
®
Low Voltage Landscape Lighting
AMP
®
HydraPro
TM
LED Underwater Light
AUL-8001-25-B-BZ (Constant Output)
AMP
®
HydroPro
TM
LED Underwater Light
AUL-8001-25-B-BZ
INSTALLATION & MAINTENANCE GUIDE
www.amplighting.com
–2–
Important Safety Instructions: Read Before Installation
!
This luminaire is intended for installation in accordance with local codes
and the National Electric Code (NEC). Failure to adhere to these codes and
instructions may result in serious injury, property damage and void the
warranty.
These instructions do not intend to cover all variations in installation,
operation maintenance or mounting situations.
1. Make sure the power is turned OFF before installing or servicing this
luminaire.
2. WARNING: risk of electrical shock. Install all luminaires 10 feet (3.05M)
or more from pool, spa or fountain.
3. This luminaire is intended to be used only with a power supply
(transformer) rated maximum of 300 watts (25 AMPS) at 15 volts.
4. Wiring connections must be made with UL listed wire connectors that are
suitable for outdoor use.
5. Position the low voltage wire and wire connector so that it is located
within 6 inches (15.2 cm) from a building structure, a luminaire or
tting.
6. The main low voltage cable is intended for shallow burial - less than 6
inches (152 mm).
Important Safety Instructions
!
INSTRUCTIONS PERTAINING TO A RISK OF FIRE, OR INJURY TO PERSONS
Lighted lamp is HOT!
WARNING – To reduce the risk of FIRE OR INJURY TO PERSONS.
1. Turn off/unplug and allow to cool before replacing lamp.
2. Lamp gets HOT quickly! Contact only switch/plug when turning on.
3. Do not touch the hot lens, guard or enclosure.
4. Keep lamp away from materials that may burn.
5. Do not touch lamp at any time. Use a soft cloth. Oil from skin may
damage lamp.
6. Do not operate the luminaire tting with a missing or damaged shield.
SAVE THESE INSTRUCTIONS
[email protected] • 813.978.3900
–3–
Important Safety Instructions: Read Before Installation
!
“WARNING-RISK OF ELECTRIC SHOCK”
1. Use only in ponds and small decorative fountains
where persons will immerse no more then their
hands and lower arms while the product is
energized.
2. DO NOT use in water intended for swimming,
wading, immersion or bathing.
3. All installer completed cable connections must be
located outside of pond or fountain.
4. Low voltage circuit must be supplied by a power
unit marked as suitable for supplying submersible
luminaries.
5. Power until must be supplied by a circuit protected
by a ground fault circuit interrupter (GFCI).
6. “Maximum depth: 18in (450 mm)”.
INSTALLATION & MAINTENANCE GUIDE
–4–
www.amplighting.com
–4–
AMP
®
HydroPro
TM
LED Underwater Light
AUL-8001-25-B-BZ
Package Contents
A. (1) Fixture
Parts (sold separately)
A. (3) Mounting Screws
B. (3) Flat Washers
A. (3) Anchors
C.
Product Dimensions
5”
4”
5”
[email protected] • 813.978.3900
–5–
INSTALLATION & MAINTENANCE GUIDE
1
2
AMP
®
HydroPro
TM
LED Underwater Light
AUL-8001-25-B-BZ
Install Horseshoe Mount
Wire Connection
Anchor
Horseshoe
Mount
Mounting
Screw
Washer
Place the horseshoe mount on the
desired location and mark (3) points
for the anchors from the holes on the
horseshoe mount.
Drill proper holes on the location and
insert anchors into the drilled holes.
Attach the horseshoe mount onto
the anchors. Pass the washers over
the mounting screws and thread the
mounting screws into the anchors to
secure the horseshoe mount. Hand
tighten until snug with a screwdriver.
NOTE: SOME APPLICATIONS ARE NOT
SUITABLE FOR PERMANENT MOUNTING AND
DO NOT REQUIRE OR WARRANT THE USE OF
SCREWS AND ANCHORS
Strip both leads from the luminaire pigtail. Using two wire connectors
(sold separately), connect the leads from the luminaire to the main supply
cable leads.
Adjust the housing to your desired direction by using the lock nuts on the
side of the housing.
Thumb Screw
Wire Connector
Main Supply Wire
Pigtail
Housing
INSTALLATION & MAINTENANCE GUIDE
–6–
www.amplighting.com
–6–
3
Install/Replace Glare Guard
AMP
®
HydroPro
TM
LED Underwater Light
AUL-8001-25-B-BZ
Remove Ring
Loosen the screws on the
faceplate and remove the
faceplate from the housing.
Screw
Faceplate
Housing
4
Install Glare Guard
Housing
Install the glare guard onto the
housing and secure it with the screws
previously removed, tightening them in
a star pattern.
Screw
Glare Guard
–6––6–
[email protected] • 813.978.3900
–7–
IS-AUL-8001-25-B-BZ-ver1.pdf
Specications and product details subject to change without notice.
© Copyright 2019, AMP
®
Lighting, Lutz FL USA 33549 • All rights reserved.
[email protected] • 813.978.3900
Help Hotline:
1-813-978-3900 • Mon-Fri 9am-6pm (EST)
www.amplighting.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

AMP Lighting HydraPro AUL-8001-25-B-BZ Instrukcja instalacji

Kategoria
Ściana
Typ
Instrukcja instalacji
Ten podręcznik jest również odpowiedni dla