Bradford White MS120R6SS Instrukcja obsługi

Typ
Instrukcja obsługi

Niniejsza instrukcja jest również odpowiednia dla

238-44965-00K REV 5/18
SOLAR ELECTRIC WATER HEATER &
SOLAR STORAGE UNIT
A Spanish language version of these instructions is available by
contacting the manufacturer listed on the rating plate.
La version espanla de estas instrucctions se puede obtener al escribirle
a la fábrica cuyo nombre aparece in la placa de especificaciones.
THE WARRANTY ON THIS WATER HEATER/STORAGE UNIT IS IN
EFFECT ONLY WHEN THE WATER HEATER/STORAGE UNIT IS
INSTALLED AND OPERATED IN ACCORDANCE WITH LOCAL CODES
AND THESE INSTRUCTIONS. THE MANUFACTURER OF THIS WATER
HEATER/STORAGE UNIT WILL NOT BE LIABLE FOR ANY DAMAGE
RESULTING FROM FAILURE TO COMPLY WITH THESE INSTRUCTIONS.
READ THESE INSTRUCTIONS THOROUGHLY BEFORE STARTING.
For your family’s comfort, safety and convenience, we recommend this
water heater/storage unit be installed and serviced by a plumbing
professional.
INSTALLATION & OPERATING
INSTRUCTION MANUAL
2
TABLE OF CONTENTS
General Information .................................................................... 3
Installation ................................................................................ 4
Locating the Water Heater/Storage Unit .................................... 4
Water Connections ................................................................. 6
Electrical Connections ............................................................ 11
(Applies only to water heaters equipped with a heating element)
Connect Solar Controller and Thermistors .................................. 12
(All models)
General Operation ...................................................................... 14
Thermostat Adjustment .......................................................... 15
(Applies only to water heaters equipped with a heating element)
Maintenance ............................................................................. 17
Parts List .................................................................................. 19
CONGRATULATIONS!
You have just purchased one of the finest water heaters/storage units
on the market today!
This installation and operating instruction manual will explain, in detail,
the installation and maintenance of your new Solar Electric Water
Heater/Storage Unit. It is strongly recommended that you contact a
plumbing professional for the installation of this water heater/storage
unit.
You should carefully read this manual, as well as the enclosed
warranty, and refer to it when questions arise. If you have any specific
questions concerning your warranty, please consult the plumbing
professional from whom your water heater/storage unit was purchased.
For your records we recommend that you write the model, serial
number and installation date of your water heater/storage unit in the
maintenance section in the back of this manual.
This manual should be kept with the water heater/storage unit.
3
GENERAL INFORMATION
This solar electric water heaters design is certified by INTERTEK (ETL)
and listed in accordance with UL 174. CETL listed in accordance with
Canadian National Standard C22.2, No. 110-M90.
This water heater/storage unit must be installed in accordance with local
codes. In the absence of local codes, install this water heater/storage unit
in accordance with the N.E.C. Reference Book (latest edition).
The warranty for this water heater/storage unit is in effect only when the
water heater/storage unit is installed, adjusted, and operated in
accordance with these Installation and Operating Instructions. The
manufacturer will not be held liable for damage resulting from alteration
and/or failure to comply with these instructions.
This water heater/storage unit may be used independently when equipped
with a heating element or as a storage unit when used in conjunction
with an existing water heater or boiler.
This water heater/storage unit has been designed and certified for the
purpose of heating potable water. The installation and use of this water
heater/storage unit for any purpose other than the heating of potable
water, may cause damage to the water heater/storage unit and create a
hazardous condition and nullify the warranty.
Do not use this appliance if any part has been submerged in water. The
plumbing professional responsible for the installation of this water
heater/storage unit should be contacted to inspect the appliance and to
replace and part of the control system, including thermostat (if equipped),
which has been submerged in water.
For water heaters equipped with a heating element; make sure that the
rating plate on the water heater is referenced for certainty that the
correct voltage is being supplied to the water heater.
CAUTION
Incorrect operation of this appliance may create a hazard to life and
property and will nullify the warranty.
DANGER
Do not store or use gasoline or other flammable, combustible,
or corrosive vapors and liquids in the vicinity of this or any other
appliance.
4
General Information continued-
A sacrificial anode(s) is used to extend tank life. Removal of any anode,
except for inspection and/or replacement, will nullify the warranty. In
areas where water is unusually active, an odor may occur at the hot
water faucet due to a reaction between the sacrificial anode and
impurities in the water. If this should happen, an alternative anode(s) may
be purchased from the supplier that installed this water heater. This will
minimize the odor while protecting the tank. Additionally, the water
heater should be flushed with appropriate dissolvers to eliminate any
bacteria.
INSTALLATION
Locating the Water Heater/Storage Unit
This water heater MUST be installed indoors out of the wind and
weather.
This water heater/storage unit shall NOT be installed in any location
where gasoline or flammable vapors are likely to be present, unless the
installation is such to eliminate the probable ignition of gasoline or
flammable vapors.
To comply with NSF requirements this water heater is to be:
IMPORTANT
Before proceeding, please inspect the water heater/storage unit and its
components for possible damage. DO NOT install any damaged components. If
damage is evident, please contact the supplier where the water heater/storage
unit was purchased or the manufacturer listed on the rating plate for replacement
parts.
WARNING
This product contains one or more chemicals known to the state of
California to cause cancer, birth defects, or reproductive harm.
WARNING
Water heater/storage units are heat producing appliances. To avoid
damage or injury, there shall be no materials stored against the
water heater/storage unit and proper care shall be taken to avoid
unnecessary contact (especially by children) with the water
heater/storage unit.
UNDER NO CIRCUMSTANCES SHALL FLAMMABLE
MATERIALS, SUCH AS GASOLINE OR PAINT THINNER BE USED OR
STORED IN THE VICINITY OF THIS WATER HEATER/STORAGE UNIT OR
ANY LOCATION FROM WHICH FUMES COULD REACH THE WATER
HEATER/STORAGE UNIT.
5
a) Sealed to the floor with sealant, in a smooth and easily cleanable
way, or
b) Installed with an optional leg kit that includes legs and/or
extensions that provide a minimum clearance of 6’’ beneath the
water heater.
6
Locating the Water Heater/Storage Unit continued-
The location where this water heater/storage unit is to be installed is of
the utmost importance. Before installing this water heater/storage unit,
consult the installation section of these instructions. After reading these
Installation and Operating instructions, select a location for the water
heater/storage unit where the floor is level and is easily accessible to a
power supply and water connections. It is recommended that the water
heater/storage unit be located near the center of greatest hot water usage
to prevent heat loss through the pipes. DO NOT locate the water
heater/storage unit where water lines could be subjected to freezing
temperatures. Locate the water heater/storage unit so that access panels
and drain valves are accessible.
Water heater/storage unit corrosion and component failure can be caused
by the heating and breakdown of airborne chemical vapors. Examples of
some typical compounds that are potentially corrosive are: spray can
propellants, cleaning solvents, refrigerator and air conditioning
refrigerants, swimming pool chemicals, calcium and sodium chloride
(salts), waxes and process chemicals. These materials are corrosive at
very low concentration levels with little or no odor to reveal their
presence.
NOTE: DAMAGE TO THE WATER HEATER/STORAGE UNIT CAUSED BY
EXPOSURE TO CORROSIVE VAPORS IS NOT COVERED BY THE
WARRANTY. DO NOT OPERATE THE WATER HEATER/STORAGE UNIT IF
EXPOSURE HAS OR WILL OCCUR. DO NOT STORE ANY POTENTIALLY
CORROSIVE COMPOUNDS IN THE VICINITY OF THE WATER
HEATER/STORAGE UNIT.
This water heater/storage unit must be located in an area where leakage
of the tank or water line connections and the combination temperature
and pressure relief valve will not result in damage to the area adjacent to
the water heater/storage unit or to lower floors of the structure. When
such locations cannot be avoided, a suitable drain pan must be installed
under the water heater/storage unit. The drain pan must have a minimum
length and width of at least 4 in. (10.2 cm) greater than the diameter of
the water heater. The drain pan, as described above, can be purchased
from your plumbing professional. The drain pan must be piped to an
adequate drain. The piping must be pitched for proper drainage.
Note: For California installation this water heater must be braced,
anchored, or strapped to avoid falling or moving during an earthquake.
See instructions for correct installation procedures. Instructions may be
obtained from the DSA Headquarters Office, 1102 Q Street, Suite 5100,
Sacramento CA 95811.
7
Water Connections
Note: Before proceeding with the installation, close the main water supply
valve.
After shutting the main water supply valve, open a faucet to relieve the
water line pressure to prevent any water from leaking out of the pipes
while making the water connections to the water heater/storage unit.
After the pressure has been relieved, close the faucet. Make the proper
plumbing connections between the water heater/storage unit and the
plumbing system in the house. Install a shut-off valve in the cold water
supply line.
If this water heater/storage unit is installed in a closed water supply
system, such as the one having a back-flow preventer in the cold water
supply, provisions shall be made to control thermal expansion. DO NOT
operate this water heater/storage unit in a closed system without
provisions for controlling thermal expansion. Your water supplier or local
plumbing inspector should be contacted on how to control this situation.
After installation of the water lines, open the main water supply valve and
fill the water heater/storage unit. While the water heater/storage unit is
filling, open several hot water faucets to allow air to escape from the
water system. When a steady stream of water flows through the faucets,
close them and check all water connections for possible leaks. NEVER
OPERATE THE WATER HEATER/STORAGE UNIT WITHOUT FIRST BEING
CERTAIN IT IS FILLED WITH WATER.
CAUTION
If sweat fittings are to be used, DO NOT apply heat to the nipples
of the water heater/storage unit. Sweat the tubing to the adapter
before fitting the adapter to the water connections. It is imperative
that heat is not applied to the nipples containing a plastic liner.
8
Water Connections continued-
WARNING
For protection against excessive temperatures and pressure, install
temperature and pressure protective equipment required by local codes,
but not less than a combination temperature and pressure relief valve
certified by a nationally recognized testing laboratory that maintains
periodic inspection of production of listed equipment or materials, as
meeting the Requirements for Relief Valves and Automatic Gas Shutoff
Devices for Hot Water Supply Systems, ANSI Z21.22, and the Standard
CAN1-4.4 Temperature, Pressure, Temperature and Pressure Relief
Valves and Vacuum Relief Valves. The combination temperature and
pressure relief valve shall be marked with a maximum set pressure, not
to exceed the maximum working pressure of the water heater/storage
unit. The combination temperature and pressure relief valve shall also
have an hourly rated temperature steam BTU discharge capacity not
less than the hourly input rating of the water heater/storage unit.
Install the combination temperature and pressure relief valve into the
opening provided and marked for this purpose on the water
heater/storage unit
Note: Some models may already be equipped or supplied with a
combination temperature and pressure relief valve. Verify that the
combination temperature and pressure relief valve complies with local
codes. If the combination temperature and pressure relief valve does not
comply with local codes, replace it with one that does. Follow the
installation instructions above on this page.
Install a discharge line so that water discharged from the combination
temperature and pressure relief valve will exit within six (6) inches
above, or any distance below the structural floor and cannot contact any
live electrical part. The discharge line is to be installed to allow for
complete drainage of both the temperature and pressure relief valve and
the discharge line. The discharge opening must not be subjected to
blockage or freezing. DO NOT thread, plug or cap the discharge line. It
is recommended that a minimum of four (4) inches (10.2 cm) be
provided on the side of the water heater/storage unit for servicing and
maintenance of the combination temperature and pressure relief valve.
Do not place a valve between the combination temperature and
pressure relief valve and the tank.
9
Water Connections continued-
This water heater/storage unit is designed to be used only with forced circulation.
The pump may be mounted directly on top of the unit. The plumbing professional
installing the water heater/storage unit has the option of using either the top or
side connections (if applicable) for the pump suction and collector return lines. If
the side connections are used, the corresponding top connections must be capped
(plugged). Some water heater/storage units are manufactured with plugs installed
in the side connections MS(80,120). If the side connections are to be used, the
plugs installed at the factory must be removed. Connect the inlet side of the pump
to the line marked pump suction connection. Connect the outlet of the pump to
the inlet of the solar connector. The outlet of the collector should be connected to
the fitting marked collector return.
IMPORTANT
FAILURE TO INSTALL AND MAINTAIN A NEW, LISTED 3/4’’ X 3/4’’
TEMPERATURE-PRESSURE RELIEF VALVE WILL RELEASE THE
MANUFACTURER FROM ANY CLAIM WHICH MIGHT RESULT FROM
EXCESSIVE TEMPERATURE AND PRESSURES.
CAUTION
Under certain conditions, water in this water heater/storage unit
may become excessively hot. It is recommended that an ASSE
approved mixing valve may be installed in the outlet line to reduce
the risk of scald injury by preventing point of discharge water
temperatures in excess of 140°F (60° C).
WARNING
Hydrogen gas can be produced in a hot water system served by this
water heater/storage unit that has not been used for a long period
of time (generally two weeks or more). Hydrogen gas is extremely
flammable. To reduce the risk of injury under these conditions, it is
recommended that the hot water faucet be opened for several
minutes at the kitchen sink before using any electrical appliance
connected to the hot water system. If hydrogen is present, there
will probably be an unusual sound such as air escaping through the
pipe as the water begins to flow. There should be no smoking or
open flame near the faucet at the time it is open.
CAUTION
INCREASING THE THERMOSTAT SETTING (IF APPLICABLE) ABOVE
THE PRESET TEMPERATURE MAY CAUSE SEVERE BURNS AND
CONSUME EXCESSIVE ENERGY. HOTTER WATER INCREASES THE
RISK OF SCALD INJURY.
10
Water Connections continued-
The two fittings on top not used for the pump suction and collector
return lines are for connecting the cold water inlet supply and the hot
water outlet supply.
A bleed valve shall be installed in the system above the level of the pump
in order to bleed the air out of the water lines.
If this water heater/storage unit is installed on a system utilizing any heat
transfer solution other than potable water, a separate heat exchanger
must be installed. A qualified heat exchanger must be constructed in such
a manner that failure of the heat exchanger will not result in
contamination of the potable water. If a separate heat exchanger is used,
forced circulation must be used between the heat exchanger and the
solar storage unit. Using either the top or side connections (if applicable),
connect the inlet of the pump to the pump suction connection and return
line from the heat exchanger to the collector return connection.
Do not install a check valve or any other device that would prevent the
reverse flow of water unless required by local codes. A closed system will
result and frequent operation of the relief valve will occur.
After the installation of all water lines is complete, open the main water
supply valve and fill the water heater/storage unit. Open several hot
water faucets to allow air to escape from the system while the water
heater/storage unit is filling. When water passes through all the faucets,
close the faucets and check for possible leaks in the system.
This water heater/storage unit can deliver scalding temperature water at
any faucet in the system. Be careful whenever using hot water to avoid
scalding injury. Certain appliances such as dishwashers and automatic
clothes washers may require increased temperature water. By setting the
thermostat on this water heater/storage unit to obtain increased
temperature water required by these appliances, you may create the
potential for scald injury.
To protect against injury, you should install an ASSE approved mixing
valve in the water system. This valve will reduce point of discharge
temperature by mixing cold and hot water in branch supply lines. Such
lines are available from the local plumbing supplier. Please consult with a
plumbing professional.
IMPORTANT
This water heater/storage unit does not contain a heat exchanger,
therefore, only potable water may be allowed to enter the water
heater/storage unit.
11
Water Connections continued-
Figure 1
Figure 2












12
Electrical Connections
This section applies to water heaters equipped with a heating element.
Before any electrical connections are made, be sure that the water heater
is full of water and that the valve in the cold water supply line is open.
Check the rating plate and wiring diagram before proceeding. This solar
electric water heater was built and wired in accordance with the
INTERTEK testing approvals requirements. The temperature limiting device
is of the manual reset, trip-free type and has been factory installed to
interrupt all ungrounded power supply conductors in the event of
thermostat failure. Thermostats are factory set and wired in accordance
with the wiring diagram fastened to the inside of the top access panel.
The plumbing supplier in your area ordered this water heater wired at the
factory to comply with existing area codes, but local utility codes may
require or allow other circuitry. Consult your local power company to
determine the correct electrical hook-up in order to meet local utility and
building codes and in order to obtain the most economical rates. Also
check to find out if you are required to obtain a permit before starting the
installation. The maximum wattage and rated voltage are shown on the
water heater data plate. The water heater must be well grounded. A
green ground screw is provided at the electrical connection point for
connecting a ground wire.
If this water heater is equipped with a 240V, 4500W heating element,
the recommended fuse size is 30A.
13
Connect Solar Controller and Thermistors
Sensor wires are provided for connection to the controller in a separate
junction box located on top of the water heater. The brown twisted wires
provide thermistor wiring from the controller to the lower control cover. The
orange twisted wires provide thermistor wiring from the controller to the upper
control cover. The orange wiring would be used for controllers that have
connections for a second tank location.
Refer to Figure 3 for connecting the thermistor and pressing it against the
tank. This figure illustrates the opening under the upper and lower control
covers. While the lower control location does not hold a thermostat, the
process is the same.
1. Positively assure all electrical connections are unpowered whenever
removing the control covers.
2. Strip the twisted wire ends and use wire nuts to securely connect the
thermistor wires.
3. With a flat blade screwdriver or similar device used as a wedge, pull
the sensor plate away slightly from the water heater tank.
4. Slide the thermistor between the plate and the water heater tank. The
solar thermistor should be inserted as shown in the upper portion of
the plate.
5. Verify that the sensor plate provides enough pressure to hold the
thermistor in place.
6. To assure that the thermistor does not move, apply a small amount of
high temperature silicon sealant in the gap produced where the
thermistor has been inserted.
7. Return power to the water heater once the covers are in place.
NOTICE
A solar control and thermistors are not supplied with this water heater. The
Tekmar 156, when installed according to manufacturer’s instructions, is an
acceptable controller. Other solar controller manufacturers such as Steca
and Resol provide controllers appropriate for use with this water heater.
Thermistors are not included with the water heater. Thermistors must be
purchased with the solar controller to ensure capability with the selected
control. Contact the solar controller manufacturer for details.
14
Connect Solar Controller and Thermistor continued-
Figure 3
Wiring and Placement for the Solar Control Thermistor
15
GENERAL OPERATION
Before closing the switch to allow electric current (if applicable) to flow
to the water heater, make certain that the water heater is full of water
and that the cold water inlet valve is open. Complete failure of the
heating element (if applicable) will result if they are not totally immersed
in water at all times. When the switch is closed, the operation of this
solar electric water heater is automatic. The thermostat (if applicable) are
preset to the ‘‘HOT’’ setting to provide a water temperature of
approximately 120° F (49°C) to reduce the risk of scald injury.
Care must be taken whenever using hot water to avoid scalding injury.
Certain appliances require high temperature hot water (such as
dishwashers and automatic clothes washers).
TO FILL THE WATER HEATER/STORAGE UNIT:
1. Close the water heater drain valve by turning the knob clockwise.
2. Open the cold water supply shut-off valve.
3. Open several hot water faucets to allow air to escape from the
system.
4. When a steady stream of water flows from the faucets, the water
heater is filled. Close the faucets and check for water leaks at the
water heater drain valve, combination temperature and pressure relief
valve and the hot and cold water connections.
TO DRAIN THE WATER HEATER/STORAGE UNIT:
Should it become necessary to completely drain the water heater/storage
unit, make sure you follow the steps below:
1. Disconnect the power supply to the water heater (if applicable).
Consult the plumber or electric company in your area for service.
2. Close the cold water supply shut-off valve.
3. Open the drain valve on the water heater/storage unit by turning the
knob counter-clockwise. The drain valve has threads on the end that
will allow connection of a standard hose coupling.
4. Open a hot water faucet to allow air to enter the system.
To refill the water heater/storage unit, refer to ‘‘TO FILL THE WATER
HEATER/STORAGE UNIT’’.
CAUTION
Scalding may occur within five (5) seconds at a temperature setting
of 140°F (60° C).
16
Thermostat Adjustment
This section applies to water heaters equipped with a heating element.
The temperature of the water can be changed by adjusting the
thermostat. Before any work is done on the water heater, disconnect all
power to the water heater by opening the switch at the main electrical
circuit breaker or fuse box. Remove the access panels or front panel on
table tops, fold the insulation outward away from the controls. Set the
thermostat to the desired water temperature using a screw driver to move
the thermostat pointer. The thermostat has been factory preset to
approximately 120° F (49° C). Rotate the temperature dial clockwise to
increase water temperature. Replace the insulation making sure that the
controls are well covered and that the plastic terminal shield has not been
displaced; replace the access panel. The water heater is now ready for
operation and the main switch can be closed.
Figure 4
CAUTION
Before adjusting thermostat, turn off power supply to the water heater.
17
Maintenance continued-
Table 1
Figure 5
DANGER
Hotter water increases the risk of scald injury. Scalding may occur within
five (5) seconds at a temperature setting of 140°F (60°C). To protect
against hot water injury, install an ASSE approved mixing valve in the
water system. This valve will reduce point of discharge water
temperatures by mixing cold and hot water in branch water lines. A
licensed plumbing professional or local plumbing authority should be
consulted.
Note: This water heater/storage unit is equipped with an energy cut out
device to prevent overheating. Should overheating occur, turn off the
electrical supply (if applicable) to the water heater/storage unit and
contact a qualified service technician.
APPROXIMATE TIME/TEMPERATURE RELATIONSHIPS IN
SCALDS
120°F (49°C)
More than 5 minutes
125°F (52°C)
1½ to 2 minutes
130°F (54°C)
About 30 seconds
135°F (57°C)
About 10 seconds
140°F (60°C)
Less than 5 seconds
145°F (63°C)
Less than 3 seconds
150°F (66°C)
About 1½ seconds
155°F (68°C)
About 1 second












18
MAINTENANCE
Shut off the electric power (if applicable) whenever the water supply is
turned off. Shut off the electric power (if applicable) and water supply,
drain the heater completely to prevent freezing whenever the building is
left unoccupied during the cold weather months.
The following maintenance should be performed by a qualified service
technician at the minimum periodic intervals suggested below. In some
installations, the maintenance interval may be more frequent depending
on the amount of use and the operating conditions of the water
heater/storage unit. Regular inspection and maintenance of the water
heater/storage unit will help to insure safe and reliable operation.
1. Annually check the operation of the thermostat (if applicable).
2. Bi-annually check the seal around the heating element for leaks (if
applicable). If there is any sign of leaking, disconnect the power supply
to the water heater and contact the plumbing professional that
installed this water heater or a qualified service technician.
3. At least once a year, check the combination temperature and pressure
relief valve to insure that the valve has not become encrusted with
lime. Lift the lever at the top of the valve several times until the valve
seats properly without leaking and operates freely.
4. If the combination temperature and pressure relief valve on the
appliance discharges periodically, this may be due to thermal
expansion in a closed water supply system. Contact the water supplier
or local plumbing inspector on how to correct this situation. Do not
plug the combination temperature and pressure relief valve outlet.
5. Monthly drain off a gallon of water from the water heater/storage unit
to remove silt and sediment.
IMPORTANT
The water heater/storage unit should be inspected at a minimum of
annually by a qualified service technician for damaged components. DO
NOT operate this water heater/storage unit if any part is found
damaged.
WARNING
When lifting lever of temperature-pressure relief valve, hot water
will be released under pressure. Be certain that any released water
does not result in bodily injury or property damage.
WARNING
THIS WATER MAY BE HOT.
19
Maintenance continued-
6. A combination sacrificial anode rod has been installed to extend tank
life. The anode rod should be inspected periodically and replaced when
necessary to prolong tank life. Water conditions in your area will
influence the time interval for inspection and replacement of the anode
rod. Contact the plumbing professional who installed the water
heater/storage unit or the manufacturer listed on the rating plate for
anode replacement information.
Contact your supplier or plumbing professional for replacement parts or
contact the company at the address displayed on the rating plate of the
water heater/storage unit. For faster and better service, please provide
the part name, model, and serial number(s) of the water heater(s)/storage
unit(s) when ordering parts.
READ THE WARRANTY FOR A FULL EXPLANATION OF THE LENGTH OF
TIME THAT PARTS AND THE WATER HEATER/STORAGE UNIT ARE
WARRANTED.
Manufactured under one or more of the following U.S. Patents: 5,277,171;
5,341,770; 5,372,185; 5,485,879; 5,574,822; 5,596,952; 5,660,165;
5,682,666; 5,761,379; 5,943,984; 5,954,492; 5,988,117; 6,056,542;
6,142,216; 6,442,178; 6,684,821; 6,935,280; 7,063,132; 7,063,133;
7,007,748; 7,270,087; 7,334,419; 7,337,517; 7,409,925; 7,458,341;
7,559,293; 7,621,238; 7,634,976; 7,650,859; 7,665,210; 7,665,211;
7,699,026; 7,866,168; 7,900,589; 7,971,560; 7,992,526 8,082,888;
8,146,772; Other U.S. and Foreign patent applications pending. Current
Canadian Patents: 2,092,105; 2,107,012; 2,108,186; 2,112,515;
2,143,031; 2,239,007; 2,262,174; 2,314,845; 2,409,271; 2,476,685;
2,504,824; 2,548,958
Complete the following information and retain for future reference:
Model No:______________________________________________________
Serial No:______________________________________________________
Service Phone
Days: ______________________Nights:_____________________________
Address:_______________________________________________________
Supplier:_______________________________________________________
Supplier Phone No:______________________________________________
CAUTION
FOR YOUR SAFETY, DO NOT ATTEMPT TO REPAIR THERMOSTAT,
HEATING ELEMENTS, OR ELECTRICAL WIRING (IF APPLICABLE).
REFER SUCH REPAIRS TO A QUALIFIED SERVICE TECHNICIAN.
20
PARTS LIST
Figure 6
Item and Description
1
Tube--- Pump suction
7
T & P valve
13
Thermostat cover
2
Anode/Outlet Nipple
8
Elec. Junction box
14
Element gasket
3
Tube--- Collector return
9
Hole closure
15
Heating element
4
Diptube-Inlet
10
Access cover
16
Thermostat bracket
5
Junction box cover
11
Drain valve
6
Junction box cover
12
Thermostat
Note: Items ‘‘12’’ through ‘‘15’’ apply only to water heaters equipped with a
heating element.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21

Bradford White MS120R6SS Instrukcja obsługi

Typ
Instrukcja obsługi
Niniejsza instrukcja jest również odpowiednia dla

w innych językach