VOLT
®
Forged Brass Underwater Light
VUL-680 Series
Important: Please Read Before Installation
INSTALLATION INSTRUCTIONS
This luminaire is intended for installation in accordance with local codes and the
National Electric Code (NEC). Failure to adhere to these codes and instructions may
result in serious injury, property damage and void the warranty.
These instructions do not intend to cover all variations in installation, operation
maintenance or mounting situation.
1. Make sure that the power is turned OFF before installing or servicing this
luminaire.
2. Use only in ponds and small decorative fountains where person will immerse no
more than their hands and lower arms while the product is energized.
3. DO NOT use in water intended for swimming, wading, immersion or bathing.
4. All installer completed cable connections must be located outside of pond or
fountain.
5. Low voltage circuit must be supplied by a power unit marked as suitable for
supplying submersible luminaires.
6. Power unit must be supplied by a circuit protected by a ground fault circuit
interrupter (GFCI).
7. Maximum depth 18”
8. This luminaire is intended to be used only with a power supply (transformer) rated
maximum of 300 watts (25 AMPS) at 15 volts.
9. Wiring connections must be made with wire connectors that is suitable for outdoor
use.
10. Position the low voltage wire and wire connector so that it is located within 6
inches (15.2 cm) from a building structure, a luminaire or tting.
11. The main low voltage cable is intended for shallow burial - less than 6 inches (152
mm)
12. If additional lengths of low voltage cable is required, please contact www.
voltlighting.com or call 1-813-978-3700.
!
www.voltlighting.com