Classic Exhibits VK-2916 Setup Instructions

Typ
Setup Instructions
www.classicexhibits.com
Step 1
Page 1 of 5
866.652.2100
© 2015
WHEN DISASSEMBLING ALUMINUM EXTRUSION, TIGHTEN ALL
SETSCREWS AND LOCKS TO PREVENT LOSS DURING SHIPPING
Order #XXXXX - VK-2916 General Layout
Plan View
10’
20’
www.classicexhibits.com
Step 2
Page 2 of 5
866.652.2100
© 2015
WHEN DISASSEMBLING ALUMINUM EXTRUSION, TIGHTEN ALL
SETSCREWS AND LOCKS TO PREVENT LOSS DURING SHIPPING
Order #XXXXX - General Information
The Tool Typical Connection
Horizontal Inline Connection (remove only one setscrew)
Base Plate Connection Vertical Connection
(remove only two setscrews)
Most Visionary Designs exhibits can be
assembled with the supplied Hex Key Tool.
Occasionally, a flat head screwdriver may
be required.
Most horizontal extrusion connections have a patented expandable lock. This lock inserts into
the groove of an opposing extrusion. Tightening the lock with the Hex Key Tool expands the lock
and creates a strong positive connection.
Remove only (1) setscrew when disassembling. Replace setscrew in
extrusion after assembling it. Before packing, replace setscrew in
extrusion to avoid losing it.
Attach base plate to round or square
vertical extrusion using the bolt provided.
Be careful not to strip the threads.
When vertical extrusions are packed in
portable cases rather than crates or
tubs, they must broken down into
smaller sections which then require
assembly.
Remove only (2) setscrews when
disassembling. Replace setscrews in
extrusion after assembling it. Before
packing, replace setscrews in extrusion
to avoid losing them.
Using Your Setup Instructions
The Visionary Designs Setup Instructions are created specifically for your
configuration. They are laid out sequentially, including an exploded view of
the entire display, and then a logical series of detailed steps to assemble the
main structure and components. We encourage you to study the instructions
before attempting to assemble your exhibit.
Each page reminds you to tighten the setscrews after disassembling your
exhibit to prevent loss of the locks and setscrews (see below in RED).
This is VERY IMPORTANT.
Cleaning and Packing Your Display
1) Use care when cleaning aluminum extrusion or acrylic inserts. Use only
non-abrasive cleaners.
2) When cleaning laminate inserts or countertops, use mild cleansers and a
soft material such as cotton.
3) Keep all display components away from extreme heat and long exposure
to sunlight to avoid warping and fading.
4) Retain all packing material. It will make re-packing much easier and will
reduce the likelihood of shipping damage.
Typical Connection (cont’d)
Numbered Label
Each extrusion contains a numbered label which
corresponds with setup instructions.
The label is located within a groove of the extrusion
(when possible). With Visionary Designs the labels
contain Black numbers unless otherwise specified.
Detail C E liateDD liateDDetail B
Detail A
Setscrews
www.classicexhibits.com
Step 1
Page 1 of 5
866.652.2100
© 2015
WHEN DISASSEMBLING ALUMINUM EXTRUSION, TIGHTEN ALL
SETSCREWS AND LOCKS TO PREVENT LOSS DURING SHIPPING
Order #XXXXX - Backwall Assembly
221
1
3
4
5
7
8
9
3
4
5
6
7
89
10
10
When assembled
Item
1/1
2/2
3/3
4/4
5/5
6
7/7
8/8
9/9
10
Qty.
1/1
1/1
1/1
1/1
1/1
1
1/1
1/1
1/1
2
Description
Oval Baseplate with Notch
Oval Baseplate
86” Horizontal Extrusion
86” Horizontal Extrusion
86” Horizontal Extrusion
86” Horizontal Extrusion
86” Horizontal Extrusion
80” Vertical Extrusion
80” Vertical Extrusion
20” Horizontal Extrusion
Steps:
1) Connect Baseplates [1, 2, 1, 2] to Vertical
Extrusions [8, 9, 8, 9]
2) Connect Horizontal Extrusions [3, 4, 5, 7] between
Vertical Extrusions [8, 9].
3) Connect Horizontal Extrusions [3, 4, 5, 6, 7] between
Vertical Extrusions [8, 9].
4) Connect Horizontal Extrusions [10] between
Vertical Extrusions [9, 8].
5) Attach GRAPHIC to assembled frame with VELCRO
VELCRO Location:
FRONT VIEW
VELCRO Locations indicated in BLUE
Top Front
VELCRO Location:
Bottom Front
GRAPHIC
GRAPHIC
GRAPHIC
VELCRO Location:
Bottom Front
www.classicexhibits.com
Step 2
Page 2 of 5
866.652.2100
© 2015
WHEN DISASSEMBLING ALUMINUM EXTRUSION, TIGHTEN ALL
SETSCREWS AND LOCKS TO PREVENT LOSS DURING SHIPPING
Order #XXXXX - Header Assembly
Steps:
1) Attach header pieces together as shown.
2) Apply graphic to front of assembled header.
3)
Attach assembled header frame to ceiling
by locking to connectors where indicated.
Note: Frame should be assembled from Backside.
A
B
C
D
Backside View
Front View
Front View
Lock
Lock
Lock
Lock
Part Number
A/A
B/B
C/C
D/D
Qty
1/1
1/1
1/1
1/1
Description
90” Lower Horizontal Extrusion
8.75“ Tapered cut Vertical Extrusion
14” Tapered cut Vertical Extrusion
93” Curved Horizontal Extrusion
NOTE: Header frame must stay assembled when shipping in crate
Assembled Header Frame with Grpahic at Front
Lock
Lock
Connector
Ceiling
Velcro Applied to Front Perimeter of Frame
A
BC
D
Backside View
Lock
Lock
LockLock
www.classicexhibits.com
Step 3
Page 3 of 5
866.652.2100
© 2015
WHEN DISASSEMBLING ALUMINUM EXTRUSION, TIGHTEN ALL
SETSCREWS AND LOCKS TO PREVENT LOSS DURING SHIPPING
Order #XXXXX - Attachments
Backwall Counter
Backwall Counter
When assembled
Shelf
Shelf
Shelf
Shelf
Wing
Wing
Steps:
1) Connect Shelf Supports to Horizontal Backwall Extrusions
(see Detail).
2) Place Backwall Counters in position.
3) Attach Standoff Barrells to top of Backwall Counter.
4) Place Shelves onto Shelf Supports and Standoff Barrells.
5) Attach Monitor Mounts to backwall (see Detail).
6) Attach Wings to Verticals using A10 Clamps (see Detail)
Tighten set screw to
secure A10 to extrusion.
A10 Clamp Detail
Tighten knob to secure
wing in place.
1
2
3
Attach wall plate to
horizontal bar using
bolts and wing nuts
Hook monitor brackets over
top of wall plate, then secure
with safety bolts to bottom
of monitor brackets.
Monitor Mount Attachment
Pill Slot Detail Example
Pill Slot
Tighten Set Screw
to secure.
www.classicexhibits.com
Step 4
Page 4 of 5
866.652.2100
© 2015
WHEN DISASSEMBLING ALUMINUM EXTRUSION, TIGHTEN ALL
SETSCREWS AND LOCKS TO PREVENT LOSS DURING SHIPPING
Order #XXXXX - Header Attachment
Steps:
1) Attach Headers to Vertical Extrusions as shown.
www.classicexhibits.com
Step 5
Page 5 of 5
866.652.2100
© 2015
WHEN DISASSEMBLING ALUMINUM EXTRUSION, TIGHTEN ALL
SETSCREWS AND LOCKS TO PREVENT LOSS DURING SHIPPING
Order #XXXXX - MOD-1234 Workstation Assembly
Item
1
2
3
4
5
6
Description
41.5”h Vertical Extrusion
41.5”h Vertical Extrusion
70”h Vertical Extrusion
70”h Vertical Extrusion
13.5”w Horizontal Extrusion
14.5”w Horizontal Extrusion
Qty.
1
1
1
1
5
4
Steps:
1) Attach lower horiozntal extrusions [5 and 6] between vertical extrusions
2) Place inserts and attach door where indicated, then attach upper horizontals as shown.
3) Velcro shelf supports to inside of assembled base, then set internal shelf atop supports.
4) Place counter top on assembled base.
5) Attach monitor mount and lit racks to assembled workstation (see Detail).
LEFT Pedestal RIGHT Pedestal
1
2
3
4
5
6
Door
Internal Shelf
Connectors for Monitor
Mount attachment
Attach connector piece to rack
as shown. Then connect
assembled literature
rack to vertical extrusion.
Literature Rack Attachment
(Place where desired)
Tighten Lock
to Secure
*
**
**
Monitor Mount Attachment
Slide mounting connector
pieces into groove of
extrusion. Tighten setscrew
to secure in place.
Then attach
wall plate to connectors
usingsupplied bolts.
Setscrew
Setscrew
5
5
5
5
6
6
6
Door Stop
Door Hinges
QTY - 2
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7

Classic Exhibits VK-2916 Setup Instructions

Typ
Setup Instructions

w innych językach