AMP Lighting AFL-4011-4-B-BZ Installation & Maintenance Manual

Typ
Installation & Maintenance Manual
INSTALLATION & MAINTENANCE GUIDE
Help Hotline:
1-813-978-3900 • Mon-Fri 9am-6pm (EST)
www.amplighting.com
AMP
®
Low Voltage Landscape Lighting
AMP
®
StoutPro Par36 Flood Light
AFL-4011-4-B-BZ
AMP
®
StoutPro Par36 Flood Light
AFL-4011-4-B-BZ
INSTALLATION & MAINTENANCE GUIDE
www.amplighting.com
–2–
Important Safety Instructions: Read Before Installation
!
This luminaire is intended for installation in accordance with local codes
and the National Electric Code (NEC). Failure to adhere to these codes and
instructions may result in serious injury, property damage and void the
warranty.
These instructions do not intend to cover all variations in installation,
operation maintenance or mounting situations.
1. Make sure the power is turned OFF before installing or servicing this
luminaire.
2. WARNING: risk of electrical shock. Install all luminaires 10 feet (3.05M)
or more from pool, spa or fountain.
3. This luminaire is intended to be used only with a power supply
(transformer) rated maximum of 300 watts (25 AMPS) at 15 volts.
4. Wiring connections must be made with UL listed wire connectors that are
suitable for outdoor use.
5. Position the low voltage wire and wire connector so that it is located
within 6 inches (15.2 cm) from a building structure, a luminaire or
tting.
6. The main low voltage cable is intended for shallow burial - less than 6
inches (152 mm).
7. If additional lengths of low voltage cable are required, please contact
www.amplighting.com or call 1-813-978-3900.
Important Safety Instructions
!
INSTRUCTIONS PERTAINING TO A RISK OF FIRE, OR INJURY TO PERSONS
Lighted lamp is HOT!
WARNING – To reduce the risk of FIRE OR INJURY TO PERSONS.
1. Turn off/unplug and allow to cool before replacing lamp.
2. Lamp gets HOT quickly! Contact only switch/plug when turning on.
3. Do not touch the hot lens, guard or enclosure.
4. Keep lamp away from materials that may burn.
5. Do not touch lamp at any time. Use a soft cloth. Oil from skin may
damage lamp.
6. Do not operate the luminaire tting with a missing or damaged shield.
SAVE THESE INSTRUCTIONS
[email protected] • 813.978.3900
Product Dimensions
–3–
1
Package Contents
A. (1) Fixture
B. (1) Stake
Install Stake
6 1/2
2”
4 3/4
Determine the desired location for mounting
the xture. Hammer the stake into the
ground until ange of stake is ush to grade.
To avoid damage to the stake, place a board
on top of stake while hammering.
NOTE: If the ground is hard and the stake
is difcult to install, make a crosscut in the
ground using a at shovel.
Stake
Soil
Ground
INSTALLATION & MAINTENANCE GUIDE
–4–
www.amplighting.com
–4–
3
2
AMP
®
StoutPro Par36 Flood Light
AFL-4011-4-B-BZ
Install Lamp
Install Lens
Use a PAR36 lamp (sold separately),
with correct wattage and type as
marked on luminaire label.
Connect supply wires to screws on the
bottom of lamp, tighten until snug
with screwdriver. Push lamp into lamp
holder and seat in place.
CAUTION: Do not exceed maximum
wattage marked on luminaire label.
NOTE: DO NOT touch lamp with bare
hands. Use soft cloth to handle lamp.
Fixture Body
Lamp
Supply Wire
Install the lens to the xture body
by aligning the locking parts on
both of them. Be sure to position
the lens so when it turns it locks
properly into place.
Fixture Body
Lens
[email protected] • 813.978.3900
–5–
INSTALLATION & MAINTENANCE GUIDE
4
5
AMP
®
StoutPro Par36 Flood Light
AFL-4011-4-B-BZ
Install Fixture to Stake
Wire Connection
Clear away an area in the ground
at the wireway slot on top of the
stake. Lay luminaire pigtail into the
wireway slot and secure the xture
onto the stake. Tighten until snug.
Luminaire
Base
Stake
Pigtail
Wireway Slot
Strip both leads from the luminaire pigtail. Using two wire connectors
(sold separately), connect the leads from the luminaire to the main low
voltage supply cable leads.
Pigtail
Main Low Voltage
Supply Cable
Wire Connectors
INSTALLATION & MAINTENANCE GUIDE
–6–
www.amplighting.com
–6–
Install/Replace Lamp
AMP
®
StoutPro Par36 Flood Light
AFL-4011-4-B-BZ
Reverse Step 2 - Step 3 to expose the lamp and replace it with the
correct wattage and type marked on the luminaire label.
IMPORTANT: Halogen lamps must be protected from moisture and dust
at all times. Always reinstall the lens when removed.
–6––6–
[email protected] • 813.978.3900
–7–
IS-AAL-1018-4-X-XX-ver1.pdf
Specications and product details subject to change without notice.
© Copyright 2019, AMP
®
Lighting, Lutz FL USA 33549 • All rights reserved.
[email protected] • 813.978.3900
Help Hotline:
1-813-978-3900 • Mon-Fri 9am-6pm (EST)
www.amplighting.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

AMP Lighting AFL-4011-4-B-BZ Installation & Maintenance Manual

Typ
Installation & Maintenance Manual

w innych językach