AMP Lighting AFL-4012-4-B-BZ Instrukcja instalacji

Typ
Instrukcja instalacji

Ten podręcznik jest również odpowiedni dla

INSTALLATION & MAINTENANCE GUIDE
Help Hotline:
1-813-978-3900 • Mon-Fri 9am-6pm (EST)
www.amplighting.com
AMP
®
Low Voltage Landscape Lighting
AMP
®
DispersePro Flood Light
AFL-4012-4-B-BZ
AMP
®
DispersePro Flood Light
AFL-4012-4-B-BZ
INSTALLATION & MAINTENANCE GUIDE
www.amplighting.com
–2–
[email protected] • 813.978.3900
Product Dimensions
–3–
Install Stake
1
Board
Stake
Ground
Soil
Important Safety Instructions: Read Before Installation
!
This luminaire is intended for installation in accordance with local codes
and the National Electric Code (NEC). Failure to adhere to these codes and
instructions may result in serious injury, property damage and void the
warranty.
These instructions do not intend to cover all variations in installation,
operation maintenance or mounting situations.
1. Make sure the power is turned OFF before installing or servicing this
luminaire.
2. WARNING: risk of electrical shock. Install all luminaires 10 feet (3.05M)
or more from pool, spa or fountain.
3. This luminaire is intended to be used only with a power supply
(transformer) rated maximum of 300 watts (25 AMPS) at 15 volts.
4. Wiring connections must be made with UL listed wire connectors that are
suitable for outdoor use.
5. Position the low voltage wire and wire connector so that it is located
within 6 inches (15.2 cm) from a building structure, a luminaire or
tting.
6. The main low voltage cable is intended for shallow burial - less than 6
inches (152 mm).
7. If additional lengths of low voltage cable are required, please contact
www.amplighting.com or call 1-813-978-3900.
Important Safety Instructions
!
INSTRUCTIONS PERTAINING TO A RISK OF FIRE, OR INJURY TO PERSONS
Lighted lamp is HOT!
WARNING – To reduce the risk of FIRE OR INJURY TO PERSONS.
1. Turn off/unplug and allow to cool before replacing lamp.
2. Lamp gets HOT quickly! Contact only switch/plug when turning on.
3. Do not touch the hot lens, guard or enclosure.
4. Keep lamp away from materials that may burn.
5. Do not touch lamp at any time. Use a soft cloth. Oil from skin may dam-
age lamp.
6. Do not operate the luminaire tting with a missing or damaged shield.
SAVE THESE INSTRUCTIONS
Package Contents
A. (1) Fixture
B. (1) Stake
Determine the desired location for
mounting the luminaire. Hammer the
stake into the ground until ange
of stake is ush to grade. To avoid
damage to the stake, place a board
on top of the stake while hammering.
NOTE: If the ground is hard and the
stake is difcult to install, make a
crosscut in the ground using a at
shovel.
3.25”
2.5”
1.5”
2.5”
INSTALLATION & MAINTENANCE GUIDE
–4–
www.amplighting.com
–4–
Wire Connections
3
Install Fixture Body to Stake
2
[email protected] • 813.978.3900
–5–
INSTALLATION & MAINTENANCE GUIDE
Adjust Fixture Body
4
AMP
®
DispersePro Flood Light
AFL-4012-4-B-BZ
AMP
®
DispersePro Flood Light
AFL-4012-4-B-BZ
Clear away an area on the ground at
the wireway slot on top of the stake.
Lay the luminaire pigtail into the
wireway slot and thread the xture
onto the stake. Tighten using the
lock nut to secure it to the base.
Fixture Body
Pigtail
Wireway Slot
Stake
Strip both leads from the luminaire pigtail. Using two wire connectors (sold
seperately), connect the leads from the luminaire to the main supply cable
leads.
Pigtail
Main Supply Cable
Wire Connectors
Use the included Allen wrench to
unlock the set screw and adjust the
xture body to your desired direction.
Tighten the set screw once your desired
angle is achieved.
Fixture
Body
Allen
Wrench
Set Screw
Adjust
Replace Lens
Remove Glare Guard with Lens
1
Loosen the thumb screws, then remove
the glare guard and the lens from the
xture body.
Fixture
Body
Glare
Guard
Thumb Screw
Replace Lens
2
Remove the lens from the rubber gasket,
then replace it with the lens you would
like to use.
Glare
Guard
Gasket and
Lens
INSTALLATION & MAINTENANCE GUIDE
–6–
www.amplighting.com
–6–
[email protected] • 813.978.3900
–7–
Install Glare Guard with Lens
6
AMP
®
DispersePro Flood Light
AFL-4012-4-B-BZ
Place the glare guard and the
gasketed lens back onto the xture
body and secure with the thumb
screws previously removed. Hand
tighten until snug.
Fixture
Body
Glare
Guard
Thumb Screws
IS-AFL-4012-4-B-BZ-ver1.pdf
Specications and product details subject to change without notice.
© Copyright 2019, AMP
®
Lighting, Lutz FL USA 33549 • All rights reserved.
[email protected] • 813.978.3900
Help Hotline:
1-813-978-3900 • Mon-Fri 9am-6pm (EST)
www.amplighting.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

AMP Lighting AFL-4012-4-B-BZ Instrukcja instalacji

Typ
Instrukcja instalacji
Ten podręcznik jest również odpowiedni dla