AMP Lighting AFL-4014-4-B-BZ Instrukcja instalacji

Typ
Instrukcja instalacji

Ten podręcznik jest również odpowiedni dla

INSTALLATION & MAINTENANCE GUIDE
Help Hotline:
1-813-978-3900 • Mon-Fri 9am-6pm (EST)
www.amplighting.com
AMP
®
Low Voltage Landscape Lighting
AMP
®
SpectrumPro R7S Flood Light
AFL-4014-4-B-BZ
AMP
®
SpectrumPro R7S Flood Light
AFL-4014-4-B-BZ
Important Safety Instructions: Read Before Installation
INSTALLATION & MAINTENANCE GUIDE
!
www.amplighting.com
–2–
This luminaire is intended for installation in accordance with local codes
and the National Electric Code (NEC). Failure to adhere to these codes and
instructions may result in serious injury, property damage and void the
warranty.
These instructions do not intend to cover all variations in installation,
operation maintenance or mounting situations.
1. Make sure the power is turned OFF before installing or servicing this
luminaire.
2. WARNING: risk of electrical shock. Install all luminaires 10 feet (3.05M)
or more from pool, spa or fountain.
3. This luminaire is intended to be used only with a power supply
(transformer) rated maximum of 300 watts (25 AMPS) at 15 volts.
4. Wiring connections must be made with UL listed wire connectors that are
suitable for outdoor use.
5. Position the low voltage wire and wire connector so that it is located
within 6 inches (15.2 cm) from a building structure, a luminaire or
tting.
6. The main low voltage cable is intended for shallow burial - less than 6
inches (152 mm).
7. If additional lengths of low voltage cable are required, please contact
www.amplighting.com or call 1-813-978-3900.
Important Safety Instructions
!
INSTRUCTIONS PERTAINING TO A RISK OF FIRE, OR INJURY TO PERSONS
Lighted lamp is HOT!
WARNING – To reduce the risk of FIRE OR INJURY TO PERSONS.
1. Turn off/unplug and allow to cool before replacing lamp.
2. Lamp gets HOT quickly! Contact only switch/plug when turning on.
3. Do not touch the hot lens, guard or enclosure.
4. Keep lamp away from materials that may burn.
5. Do not touch lamp at any time. Use a soft cloth. Oil from skin may dam-
age lamp.
6. Do not operate the luminaire tting with a missing or damaged shield.
SAVE THESE INSTRUCTIONS
[email protected] • 813.978.3900
Product Dimensions
–3–
Package Contents
A. (1) Fixture Body
6.42” 3.75”
3.15”
2”
Install Stake
1
Determine the desired location
for mounting the xture.
Hammer the stake into the
ground until ange of stake
is ush to grade. To avoid
damage to the stake, place a
board on top of the stake while
hammering.
Note: If the ground is hard and
the stake is difcult to install,
make a crosscut in the ground
using a at shovel.
Board
Ground
Soil
Stake
INSTALLATION & MAINTENANCE GUIDE
–4–
www.amplighting.com
–4–
Wire Connection
3
Install Fixture Body to Stake
2
AMP
®
SpectrumPro R7S Flood Light
AFL-4014-4-B-BZ
Clear away an area in the
ground at the wireway slot on
top of the stake. Lay the supply
wires into the wireway slot and
screw the xture body on to the
stake. Tighten until snug.
Fixture Body
Ground
Supply Wires
Wireway Slot
Stake
Strip both leads from the luminaire pigtail. Using two wire connectors
(sold separately), connect the leads from the luminaire to the main
supply cable leads.
Pigtail
Main Supply
Cable
Wire Connectors
[email protected] • 813.978.3900
–5–
Remove Glare Guard
4
Install R7S Bulb
5
Loosen the set screws and remove the glare guard from the xture body.
Fixture Body
Set Screw
Glare Guard
Insert the R7S bulb with the
correct wattage and type
marked on the xture label and
push into place.
CAUTION: Do not exceed
maximum wattage marked on
luminaire label.
Bulb Base
R7S Bulb
R7S Bulb
Rotate
Before installing the glare guard back onto the xture, adjust the R7S
bulb.
Rotate the bulb inside it’s socket towards the back of the xture to
decrease the light output. To return to the normal lumen output, rotate
the bulb towards the lens.
–6–
www.amplighting.com
–6–
INSTALLATION & MAINTENANCE GUIDE
AMP
®
SpectrumPro R7S Flood Light
AFL-4014-4-B-BZ
Install Glare Guard
6
Adjust Fixture Direction
7
ROTAT E
Fixture
Set Screw
Loosen the set screw and
adjust the xture to the
desired direction. Once the
desired direction is achieved,
tighten the set screw until
snug.
Then place the glare guard back onto the xture body and secure with the
previously removed set screws. Hand tighten until snug.
Fixture
Body
Set Screw
Glare Guard
–6––6–
[email protected] • 813.978.3900
–7–
Install/Replace Bulb
Remove the glare guard to expose the R7S bulb and replace it
with the correct wattage and type marked on the xture label. Then,
reinstall the glare guard.
IMPORTANT: R7S bulb must be protected from moisture and dust at all
times. Always reinstall the glare guard when removed.
IS-AFL-4014-4-B-BZ.ver1
Specications and product details subject to change without notice.
© Copyright 2019, AMP
®
Lighting, Lutz FL USA 33549 • All rights reserved.
[email protected] • 813.978.3900
Help Hotline:
1-813-978-3900 • Mon-Fri 9am-6pm (EST)
www.amplighting.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

AMP Lighting AFL-4014-4-B-BZ Instrukcja instalacji

Typ
Instrukcja instalacji
Ten podręcznik jest również odpowiedni dla