11GB/IE
- Conductor
- Pliers
Note: DO NOT use power tools to tighten the
screws. Excessive tightening can damage the thread
of the screws.
Prior to installation
■Prior to installation, familiarise yourself with all
the instructions and diagrams in this manual as
well as with the ceiling fan itself.
■Before installation ensure that the circuit to
which the product will be connected is not live.
To do so, remove the fuse or switch off the
circuit breaker in the fuse box (position 0)
■Before mounting, check that the mounting
location is suitable for the weight of the
product.
■Check that there is no voltage using a voltage
tester.
Assembly
Note: You will need a power drill for the
installation work.
Note: Please also follow the instructions for your
power drill.
Note: The supplied fixing screws 9 are intended
for use with wooden ceiling beams. For all other
materials the appropriate fixing screws must be
purchased. Ask a specialist shop for suitable screws
for your ceiling.
Note: The mounting bracket 6 of the ceiling fan
allows it to be mounted on angled/sloped ceilings
up to an inclination of 14 °.
WARNING! Please be sure not to drill into
any electrical wiring, gas or water lines inside the
wall.
Installing the product
Note: Place the ceiling fan on a soft surface when
unpacking to avoid damaging the surface of the
ceiling fan.
Note: Do not lay the motor housing 2 on its side,
as this could bend and damage the decor housing.
Note: Remove all packaging materials from the
ceiling fan with LED light.
Installing the mounting bracket:
WARNING! DANGER OF ELECTRIC
SHOCK!
□Remove the fuse or switch off the circuit break-
er (0 setting) in the fuse box prior to installing
the mounting bracket 6
□Unscrew the right-hand screw 12 , including
the washer and tooth lock washer, which is
located at the side of the mounting bracket 6 .
□Unscrew the left-hand screw 12 together with
the washer and tooth lock washer (see Fig. B).
□Mark the drill holes using the holes in the
mounting bracket 6 intended for the fixing
screws 9 as a guide for concrete ceilings.
□Now drill the mounting holes (Ø 8 mm). Make
sure that you do not damage the power cord
(external) 13, water pipes or electrical cables.
□Insert the wall plugs 10 into the drilled holes (Ø
8 mm). If necessary, use a hammer to help you.
WICHTIG! Der gewählte Einbauort muss in
der Lage sein, das Gesamtgewicht des
Deckenventilators mit LED-Licht tragen können.
□Führen Sie das Netzkabel (extern) 13 durch die
vorgesehene zentrale Bohrung im Montage-
bügel 6 . Befestigen Sie den Montagebügel
6 mit den Unterlegscheiben 9b, Federringen
9a und Befestigungsschrauben 9 (siehe Abb.
C). Achten Sie darauf, dass mindestens 30 mm
der Befestigungsschraube 9 in den Deck-
enbalken oder die Holzunterlage geschraubt
wird.
Installing the ceiling fan:
WARNUNG! DANGER OF ELECTRIC
SHOCK!
□Before proceeding with the installation, make
sure that the power supply to which the product
is connected is not live. To do so, remove the
fuse or switch off the circuit breaker in the fuse
box (position 0).
□Using one of the holes intended for this