TP-LINK TL-SG1210MP Unmanaged Desktop PoE+ Switch Instrukcja instalacji

Kategoria
Przełączniki sieciowe
Typ
Instrukcja instalacji

Ten podręcznik jest również odpowiedni dla

Installation Guide
Unmanaged Desktop PoE+ Switch
© 2021 TP-Link 7106509234 REV6.0.0
Switches Explanation (Only for TL-SG1210MP)
O: Ports run at 10/100/1000 Mbps and support PoE power supply up to 100 m away.
On: Ports run at 10 Mbps and support PoE power supply up to 250 m away.
Extend
Connection
Note: For simplicity, we will take TL-SG1008P for example throughout the Guide.
PC
IP Camera AP
Ethernet Ports (1-8)
PoE Ports (1-4)
IP Phone
PoE Devices
Router
LAN PortWAN Port
Internet
DC Power Adapter
AC Power Cord
Note:
PoE ports can also connect to non-PoE devices, but only transmit data.
O: The PoE Auto Recovery function is disabled.
On: The switch will constantly detect the working status of a PoE powered device (PD).
When the switch nds that the PD works abnormally, the switch will reboot it.
Recovery
Note: The numbers in brackets indicate the ports where the feature takes eect. For example, when Extend(1-4) is toggled to On, the Extend mode will be enabled for ports 1-4.
O: Ports can transmit data with each other.
On: Specic ports cannot transmit data with other downlink ports. They can transmit data
only with the uplink ports.
Isolation
O: All the ports transmit data with the same priority.
On: The specic ports transmit data with a higher priority than other ports.
Priority
For TL-SG1210MP:
On: 116 W≤Total power supply < 123 W
Flashing: Total power supply ≥ 123 W
O: Total power supply < 116 W
LED Explanation
Power
PoE Status
On: Providing PoE power
Flashing: PoE fault
O: Not providing PoE power
On: Power on
O: Power o
Link/Act; Uplink 1, Uplink 2
Green On:
Running at 1000 Mbps, but no activity.
Green Flashing:
Running at 1000 Mbps and is transmitting or
receiving data.
Yellow On:
Running at 10/100 Mbps, but no activity.
O:
No device is linked to the corresponding port.
Yellow Flashing:
Running at 10/100 Mbps and is transmitting
or receiving data.
PoE Max
For TL-SG1008P:
On: 57 W≤Total power supply < 64 W
Flashing: Total power supply ≥ 64 W
O: Total power supply < 57 W
For TL-SG1210P:
On: 56 W≤Total power supply < 63 W
Flashing: Total power supply ≥ 63 W
O: Total power supply < 56 W
Frequently Asked Questions (FAQ)
The Power LED should be lit when the power system is working normally. If the Power LED is
not lit, please check as follows:
A1:
Make sure the AC power cord is connected the switch with power source properly.
A2:
Make sure the voltage of the power supply meets the requirements of the input voltage
of the switch.
A3:
Make sure the power source is on.
Q1. The Power LED is not lit.
It is recommended that you check the following items:
A1:
Make sure that the cable connectors are rmly plugged into the switch and the device.
A2:
Make sure the connected device is turned on and working well.
A3:
The cable must be less than 100 meters long (328 feet). If Extend Mode is enabled, it
should be less than 250 meters (820 feet).
Q2. The Link/Act LED is not lit when a device is connected to the
corresponding port.
For technical support and other information, please visit
https://www.tp-link.com/support, or simply scan the QR code.
If you have any suggestions or needs on the product guides, welcome
to email tech[email protected]om.cn.
To ask questions, find answers, and communicate with TP-Link users or
engineers, please visit https://community.tp-link.com to join TP-Link
Community.
Safety Information
Keep the device away from water, re, humidity or hot environments.
Do not attempt to disassemble, repair, or modify the device. If you need service, please
contact us.
Do not use damaged charger or USB cable to charge the device.
Do not use any other chargers than those recommended.
Adapter shall be installed near the equipment and shall be easily accessible.
Use only power supplies which are provided by manufacturer and in the origin packing of
this product. If you have any questions, please don’t hesitate to contact us.
TP-Link hereby declares that the device is in compliance with the essential requirements and
other relevant provisions of directives 2014/30/EU, 2014/35/EU, 2009/125/EC, 2011/65/EU
and (EU)2015/863.
The original EU declaration of conformity may be found at
https://www.tp-link.com/en/support/ce/
EU Declaration of Conformity
PoE Disclaimer
The speed of the ports in extend mode will downgrade to 10 Mbps. The actual transmission
distance may vary due to power consumption of PoE-powered devices or the cable quality
and type.
PoE budget calculations are based on laboratory testing. Actual PoE power budget is not
guaranteed and will vary as a result of client limitations and environmental factors.
Specications
Q3. Why is PoE/PoE+ Port not supplying power for PoE devices?
When the total power consumption of connected PoE devices exceeds the maximum, the
PoE port with a smaller port number has a higher priority. The system will cut o power to
the ports with larger port numbers to ensure supplying to other ports.
Take TL-SG1008P as an example. If port 1, 2 and 4 are consuming 15.4 W respectively, and
an additional PoE device with 20 W is connected to port 3, the system will cut o the power
of port 4 to compensate for the overload.
IEEE 802.3i, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3x,
IEEE 802.3af, IEEE 802.3at, IEEE 802.1p
IEEE 802.3z (Only for TL-SG1210P/TL-SG1210MP)
CSMA/CD
For TL-SG1008P:
8 10/100/1000 Mbps RJ45 Ports, Auto-Negotiation MDI/MDIX;
PoE Ports: Port 1-4
For TL-SG1210P:
9 10/100/1000 Mbps RJ45 Ports, Auto-Negotiation MDI/MDIX;
1 1000 Mbps SFP port;
PoE Ports: Port 1-8
For TL-SG1210MP:
10 10/100/1000 Mbps RJ45 Ports, Auto-Negotiation MDI/MDIX;
1 1000 Mbps SFP port (Combo);
PoE Ports: Port 1-8
10BASE-T: UTP category 3, 4, 5 cable (maximum 100 m);
EIA/TIA-568 100 Ω STP (maximum 100 m)
100BASE-TX: UTP
category
5, 5e
cable (maximum
100
m);
EIA/TIA-568 100 Ω STP (maximum 100 m)
100BASE-FX/LX10/BX10: MMF, SMF
(Only for TL-SG1210MP)
1000BASE-T: UTP
category 5e cable or above (maximum 100 m);
EIA/TIA-568 100 Ω STP (maximum 100 m)
1000BASE-SX/LX/LX10/BX10: MMF, SMF
(Only for
TL-SG1210P/TL-SG1210MP)
TL-SG1008P: 16 Gbps
TL-SG1210P/TL-SG1210MP: 20 Gbps
4K
Store-and-Forward
Automatically learning, automatically aging
Input: 100-240 VAC, 50/60 Hz
Output: 53.5 V DC/2.43 A (For TL-SG1210MP)
53.5 V DC/1.31 A (For TL-SG1008P/TL-SG1210P)
TL-SG1008P: 64 W (up to 30 W for each PoE port)
TL-SG1210P: 63 W (up to 30 W for each PoE port)
TL-SG1210MP: 123 W (up to 30 W for each PoE port)
Ye s
TL-SG1008P: 105 mm
TL-SG1210P/TL-SG1210MP: 150 mm
Standard
Power Supply
PoE Budget
MAC Address Learning
Transfer Method
MAC Address Table
Switching Capacity
Network Media (Cable)
Interface
Protocol
Wall Mountable
Distance Between
Mounting Holes
General Specications
A1:
Before upgrading a connected PoE powered device (PD), disable PoE Auto Recovery to
avoid the PD’s damage.
A2:
When a PD does not send data packets to the switch for a long period in certain
scenarios (e.g. an IPC in sleep mode), disable PoE Auto Recovery to avoid the PD
repeatedly rebooting.
Q4. What should I notice before using the PoE Auto Recovery
feature?
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
0˚C to 40˚C (32˚F to 104˚F)
-40˚C to 70˚C (-40˚F to 158˚F)
10% to 90%RH non-condensing
5% to 90%RH non-condensing
Environmental and Physical Specications
UKCA Declaration of Conformity
TP-Link hereby declares that the device is in compliance with the essential requirements
and other relevant provisions of the Electromagnetic Compatibility Regulations 2016 and
Electrical Equipment (Safety) Regulations 2016.
The original UKCA declaration of conformity may be found at
https://www.tp-link.com/support/ukca
  • Page 1 1
  • Page 2 2

TP-LINK TL-SG1210MP Unmanaged Desktop PoE+ Switch Instrukcja instalacji

Kategoria
Przełączniki sieciowe
Typ
Instrukcja instalacji
Ten podręcznik jest również odpowiedni dla