Renishaw NC4+ Skrócona instrukcja obsługi

Typ
Skrócona instrukcja obsługi

Ten podręcznik jest również odpowiedni dla

Quick-start guide
H-6435-8500-01-A
NC4+ Blue non-contact tool setting system
Issued: 08.2019
EN
Publications for this product are available
by scanning the barcode or visiting
www.renishaw.com/ncsupport.
DE
Für dieses Produkt stehen weitere Informationen zur
Verfügung. Scannen Sie dazu den Barcode oder besuchen Sie
www.renishaw.de/ncsupport.
ES
Para acceder a las publicaciones sobre este producto
escanee el código de barras o visite
www.renishaw.es/ncsupport.
FR
Les documentations pour ce produit sont disponibles en
scannant le code barres ou en visitant
www.renishaw.fr/ncsupport.
IT
Le pubblicazioni relative a questo prodotto sono disponibili
scansionando il codice a lato oppure visitando il sito:
www.renishaw.it/ncsupport.
日本
www.renishaw.jp/ncsupport
PL
Dostęp do dokumentacji tego produktu można uzyskać,
skanując kod kreskowy lub odwiedzając witrynę
www.renishaw.pl/ncsupport.
CS
Publikace pro tento produkt jsou k dispozici po naskenování
QR kódu nebo na stránce
www.renishaw.cz/ncsupport.
RU
Если вас интересует информация об этом продукте,
отсканируйте штриход или посетите сайт
www.renishaw.ru/ncsupport
中文
(繁體)
可透過下列方式獲得此產品的出版物
透過掃描條碼,或造訪
www.renishaw.com.tw/ncsupport
中文
(简体)
可通过以下方式获得此产品的相关文档:
扫描二维码,或访问
www.renishaw.com.cn/ncsupport
한국어
본 제품에 대한 간행물은
바코드를 스캔하거나 다음을 방문하여 확인하실 수있습니다
www.renishaw.co.kr/ncsupport.
4
Software and user information
For available software, see the Probe software for machine tools – programs and features data sheet
(Renishaw part no. H-2000-2298). For more information, see wwwrenishaw.com.
Machine tool apps
Smartphone apps provide information at a user’s ngertips in a simple, convenient format. Available
globally in a wide range of languages, our free-of-charge apps give users the following information:
NC4 app Conguration (including wiring), maintenance, troubleshooting of NC4 systems.
GoProbe app Programming of Renishaw probing systems (including NC4).
Renishaw apps are available in China via Baidu and Tencent.
On-machine apps can be seamlessly integrated with a wide range of CNC controllers. Apps are
installed onto a Microsoft
®
Windows
®
-based CNC control or a Windows tablet connected to the
controller via Ethernet.
With touch interaction and intuitive design, smartphone and on-machine apps provide signicant
benets to machine tool probe users.
For more information, visit www.renishaw.com/machinetoolapps.
5
Probe status LED function
Probe status LED
Blocked beam / probe triggered
Partially blocked beam / probe untriggered
Unblocked beam / probe untriggered
For more information on these LED sequences and modes of operation, see the NC4+ Blue
non‑contact tool setting system installation and maintenance guide – Renishaw part no. H-6435-8501.
6
激光辐射
请勿直视激光光束
Laser safety and warning labels
Label B
Label A
Laser ‘On’ and probe status LED (for more information, see
the NC4+ Blue non‑contact tool setting system installation
and maintenance guide – Renishaw part no. H-6435-8501).
NOTE: Labels A and B are tted to
the transmitter unit only.
An adhesive warning label is
provided for attachment outside the
machine.
* Except for deviations pursuant to
Laser Notice No. 50 dated June 24 2007
Label A Label B
*
7
Location of the laser aperture
Access panel identication markings, denoting system range
(for more information, see the NC4+ Blue non‑contact tool
setting system installation and maintenance guide – Renishaw
part no. H-6435-8501).
Laser aperture
Caution symbol (for more information,
see “CAUTION symbol” below)
CAUTION – Laser safety
The access panel is to be removed for service
purposes only using the special tool supplied.
Before removing the panel, switch off electrical
power to the transmitter unit to avoid exposure to
the laser beam.
CAUTION symbol
The caution symbol on the access panel denotes
the following:
CAUTION – Class 3R Laser radiation
when open. Avoid direct eye exposure.
This text is not included on the access panel due,
to the limited space available.
!
!
8
This page is intentionally left blank.
i
Warranty
Equipment requiring attention under warranty must be returned to
your equipment supplier.
Unless otherwise specically agreed in writing between you and
Renishaw, if you purchased the equipment from a Renishaw
company, the warranty provisions contained in Renishaw’s
CONDITIONS OF SALE apply. You should consult these conditions
in order to nd out the details of your warranty but, in summary, the
main exclusions from the warranty are if the equipment has been:
neglected, mishandled or inappropriately used; or
modied or altered in any way except with the prior written
agreement of Renishaw.
If you purchased the equipment from any other supplier, you
should contact them to nd out what repairs are covered by their
warranty.
China RoHS
For more information, on China RoHS visit:
www.renishaw.com/mtpchinarohs.
© 2019 Renishaw plc. All rights reserved.
This document may not be copied or reproduced in whole or in
part, or transferred to any other media or language, by any means,
without the prior written permission of Renishaw plc.
The publication of material within this document does not imply
freedom from the patent rights of Renishaw plc.
Disclaimer
RENISHAW HAS MADE CONSIDERABLE EFFORTS TO
ENSURE THE CONTENT OF THIS DOCUMENT IS CORRECT
AT THE DATE OF PUBLICATION BUT MAKES NO WARRANTIES
OR REPRESENTATIONS REGARDING THE CONTENT.
RENISHAW EXCLUDES LIABILITY, HOWSOEVER ARISING,
FOR ANY INACCURACIES IN THIS DOCUMENT.
Trade marks
RENISHAW and the probe symbol used in the RENISHAW
logo are registered trade marks of Renishaw plc in the United
Kingdom and other countries. apply innovation and names and
designations of other Renishaw products and technologies are
trade marks of Renishaw plc or its subsidiaries.
Google Play and the Google Play logo are trademarks of Google
LLC.
Apple and the Apple logo are trademarks of Apple Inc., registered
in the U.S. and other countries. App Store is a service mark of
Apple Inc., registered in the U.S. and other countries.
All other brand names and product names used in this document
are trade names, trade marks, or registered trade marks of their
respective owners.
ii
EU declaration of conformity
Renishaw plc declares under its sole responsibility that the NC4+
Blue non-contact tool setting system is in conformity with all
relevant Union legislation.
The full text of the EU declaration of conformity is available at:
www.renishaw.com/mtpdoc
C
WEEE directive
The use of this symbol on Renishaw products and/or
accompanying documentation indicates that the product should
not be mixed with general household waste upon disposal. It is
the responsibility of the end user to dispose of this product at
a designated collection point for waste electrical and electronic
equipment (WEEE) to enable reuse or recycling. Correct
disposal of this product will help to save valuable resources and
prevent potential negative effects on the environment. For more
information, please contact your local waste disposal service or
Renishaw distributor.
REACH regulation
Information required by Article 33(1) of Regulation (EC)
No1907/2006 (“REACH”) relating to products containing
substances of very high concern (SVHCs) is available at:
www.renishaw.com/REACH
FCC Information to user (USA only)
47 CFR Section 15.19
This device complies with part 15 of the FCC Rules. Operation is
subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including
interference that may cause undesired operation.
47 CFR Section 15.21
The user is cautioned that any changes or modications not
expressly approved by Renishaw plc or authorised representative
could void the user’s authority to operate the equipment.
47 CFR Section 15.105
This equipment has been tested and found to comply with the
limits for a Class A digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in
a commercial environment. This equipment generates, uses, and
can radiate radio frequency energy and, if not installed and used
in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment
in a residential area is likely to cause harmful interference in which
case the user will be required to correct the interference at his own
expense.
iii
Safety
Information to the user
In all applications involving the use of machine tools or CMMs, eye
protection is recommended.
Information for the machine supplier/installer
It is the machine supplier’s responsibility to ensure that the user is
made aware of any hazards involved during operation, including
those mentioned in Renishaw product literature, and to ensure that
adequate guards and safety interlocks are provided.
Under certain circumstances, the probe signal may falsely
indicate beam not blocked. Do not rely on probe signals to halt the
movement of the machine.
Information to the equipment installer
All Renishaw equipment is designed to comply with the relevant
EU and FCC regulatory requirements. It is the responsibility of
the equipment installer to ensure that the following guidelines are
adhered to, in order for the product to function in accordance with
these regulations:
any interface MUST be installed in a position away from any
potential sources of electrical noise, i.e. power transformers,
servo drives etc;
all 0 V/ground connections should be connected to the machine
“star point” (the “star point” is a single point return for all
equipment ground and screen cables). This is very important
and failure to adhere to this can cause a potential difference
between grounds;
all screens must be connected as outlined in the user
instructions;
cables must not be routed alongside high current sources, i.e.
motor power supply cables etc. or be near high-speed data
lines;
cable lengths should always be kept to a minimum.
Equipment operation
If this equipment is used in a manner not specied by the
manufacturer, the protection provided by the equipment may be
impaired.
Warnings
Use of controls or adjustments or performance of procedures other
than those specied within this publication may result in hazardous
radiation exposure.
Switch off the power supply before carrying out maintenance on
the NC4 system.
When using the NC4 system, basic safety precautions must
always be followed to reduce the risk of re, electric shock and
personal injury, including the following:
Read all instructions before operating this product.
The device must only be installed and used by competent,
trained personnel.
Use eye protection to protect against mechanical hazards,
coolant and swarf.
Avoid inhalation of coolant vapour from the machine tool.
Do not block the air exiting from the transmitter, receiver or air
blast apertures.
The sound power emitted by the air blast equipment can
range from 70.3 dB at 3.0 bar (43.51 psi) to 78.2dB at 6.0 bar
(87.02psi). It is the responsibility of the integrator to ensure a
suitable noise assessment is performed when the equipment
is put into use.
Prevent direct exposure of the eyes to the laser beam.
Ensure that the beam is not reected into the eyes via any
reective surface.
iv
雷尼绍(上海)贸易有限公司
中国上海市静安区江场三路
288
18
幢楼
1
200436
T +86 21 6180 6416
F +86 21 6180 6418
E shanghai@renishaw.com
www.renishaw.com.cn
安全须知
用户须知
在所有涉及使用机床的应用中,建议采取保护眼睛的措施。
机床供应商/安装商须知
机床制造商有责任确保用户了解操作中存在的任何危险,包括
雷尼绍产品说明书中所述的危险,并应确保提供充分的防护装置和
安全联动装置。
在某些情况下,测头信号可能错误指示测头已复位状态。切勿单凭
测头信号来停止机床运动。
设备安装商须知
雷尼绍所有设备的设计均符合相关的EUFCC监管要求。为使产品
按照这些规定工作,设备安装商有责任保证遵守以下指导原则:
任何接口的安装位置必须远离任何潜在的电噪声源,如变压器、
伺服系统驱动装置等;
所有0伏/接地连接都应当连接到机床接地终端上(“接地终端”
是所有设备地线和屏蔽电缆的单点回路)。这一点非常重要,不
遵守此规定会造成接地之间存在电位差;
所有屏蔽装置都必须按使用说明书中所述进行连接;
电缆线路不得与电机电源电缆等高电流源并行或靠近高速数据
传输线;
电缆长度应始终保持最短。
设备操作
如果设备使用方式与制造商要求的方式不符,设备提供的保护功能
可能会减弱。
警告
在使用、调整控制元件或者执行操作时,若不按照本出版物所述的
步骤进行,可能会导致接触有害辐射。
关闭电源后,方可在NC4系统上进行维护工作。
在使用NC4系统时,必须严格遵循基本的安全防范措施,以降低火
灾、电击和人身伤害的风险。包括以下安全措施:
操作本产品之前请阅读所有使用说明。
本装置只能由接受过培训的专业人员安装和使用。
使用护目用具,预防机械伤害及冷却液和切屑污染。
避免吸入机床上的冷却液蒸汽。
请勿阻塞发射器、接收器或吹气系统的光孔气源。
吹气设备发出的声功率范围从3.0 bar时的70.3 dB6.0 bar
78.2 dB。集成商有责任确保在设备投入使用之前执行适当的
噪音评估。
请勿直视激光束。确保光束不会经任何反射表面反射到眼睛里。
v
Patents
Features of the NC4+ Blue non-contact tool setting
system and features of similar products are the subject
of one or more of the following patents and/or patent
applications:
CN 100394139
CN 1202403
CN 1660541
EP 1050368
EP 1144944
EP 1502699
EP 1562020
JP 4520240
JP 4521094
JP 4695808
TW NI-178572
US 6496273
US 6635894
US 6878953
US 7053392
US 7312433
This page is intentionally left blank.
Renishaw plc
New Mills, Wotton-under-Edge
Gloucestershire, GL12 8JR
United Kingdom
T +44 (0)1453 524524
F +44 (0)1453 524901
E uk@renishaw.com
www.renishaw.com
For worldwide contact details, visit
www.renishaw.com/contact
*H-6435-8500-01*
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Renishaw NC4+ Skrócona instrukcja obsługi

Typ
Skrócona instrukcja obsługi
Ten podręcznik jest również odpowiedni dla