3
1.4. Technical parameters (table 2.)
Table 2.
10 ports 10/100/1000Mb/s (8 x PoE + 2 x UP LINK)
with connection speed auto-negotiation and MDI/MDIX Auto Cross
IEEE 802.3af/at (1÷8 ports), 52 V DC / 30 W at each port *
IEEE802.3, 802.3u, 802.3x CSMA/CD, TCP/IP
Optical indication of
operation
Switch power supply
Link
SPD
PoE Status
~100-240 V; 50/60 Hz; 1,5 A
the PSD 520230 52V DC/2,3 A/120 W max. power supply desktop type
temperature -10 °C ÷ 40 °C,
relative humidity 5 % - 90 %, no condensation
W=190, H=27, D=105 [+/- 2 mm]
plate to be fixed surface
Protection class
EN 60950-1:2007
* The given value of 30 W per port is the maximum value. The total power consumption should not exceed 96 W.
2. Installation.
2.1. Requirements.
The unit should be mounted in confined spaces, in accordance with the 2nd environmental class, with normal
relative humidity (RH=90 % maximum, without condensation) and temperature from -10 °C to +40 °C. Ensure the free
flow of air around the unit. The PSU shall work in a vertical position that guarantees sufficient convectional air-flow
through ventilating holes of the enclosure.
The switch load balance should be done before installation. The given value of 30 W per port is the maximum value
referring to a single output. The total power consumption should not exceed 96 W. The increased demand for power is
particularly evident in the case of cameras with heaters or infrared illuminators - when launching these features, the
power consumption increases rapidly, which may adversely affect the operation of the switch. As the device is designed for
a continuous operation and is not equipped with a power-switch, therefore an appropriate overload protection in the power
supply circuit should be provided. The electrical system shall be made in accordance with applicable standards and regulations.
2.2. Installation procedure.
1. Connect switch to the PSD520230 52 V DC power supply unit desktop type.
2. Connect the power supply to the 230 V socket.
3. Connect the camera wires to the RJ45 connectors (connectors PoE).
4. Check the optical indication of switch operation (see Table 3).