1.4. Technical parameters (Table 3.)
Table 3.
6 10/100Mb/s ports (4 x PoE + 2 x UP LINK)
with connection speed auto-negotiation and MDI/MDIX Auto Cross
IEEE 802.3af/at (1÷4 ports), 52 V DC / 30 W at each port *
IEEE802.3, 802.3u, 802.3x CSMA/CD, TCP/IP
Optical indication of
operation
Switch power supply;
Link/Act;
PoE Status
~100-240 V; 50/60 Hz; 1,3 A
temperature -10°C ÷ 40°C,
relative humidity 5% - 90%, no condensation
W=482 W
1
=440 H=44 D=227 [+/-2mm]
RACK 19″ 1U, Steel plate, DC01 1,0mm color RAL 9005
Protection class
EN 60950-1:2007
* The given value of 30 W per port is the maximum value. The total power consumption should not exceed 48 W.
2. Installation
2.1. Installation procedure
1. The unit should be mounted by a qualified installer, holding relevant permits and licenses (applicable and required
for a given country) for 230 V interference and low-voltage installations.
2. The unit should be mounted in confined spaces, in accordance with the 2nd environmental class, with normal
relative humidity (RH=90% maximum, without condensation) and temperature from -10°C to +40°C.
3. The switch shall operate in a horizontal position in order to ensure free air convection in the Rack cabinet. The
switch load balance should be done prior to installation.
The given value of 30 W per port is the maximum value referring to a single output. The total power consumption
should not exceed 48 W.
The increased demand for power is particularly evident in the case of cameras with heaters or infrared illuminators
- when launching these features, the power consumption increases rapidly, which may adversely affect the
operation of the switch.
The device is designed for a continuous operation and is not equipped with a power-switch. Therefore, an
appropriate overload protection in the power supply circuit should be provided. Moreover, the user should be
informed how to disconnect the power supply unit from the mains supply (usually by assigning an appropriate fuse
in the fuse box). The electrical system shall be made in accordance with applicable standards and regulations.
2.2. Long Range mode
Switch enables operation in two modes: standard and extended range. When the Long Range switch is in STANDARD
position (see Fig. 5), PoE ports operate at 100 Mb / s up to 100 meters. After switching to EXTEND position, range is increased
to 250 meters and speed is reduced to 10 Mb / s. Additionally, VLAN function, which isolates the PoE ports between each other
(communication takes place between the UpLink ports and individual PoE), is activated. In both modes, the UpLink port speed
is 100 Mb / s.
Note: Changing the modes requires a power restart!