1.4. Technical parameters.
Table 2.
6 10/100/1000Mb/s ports (4 x PoE + 2 x UpLink)
with connection speed auto-negotiation and MDI/MDIX Auto Cross
IEEE 802.3af/at (1÷4 ports), 52 V DC / 30 W at each port *
IEEE802.3, 802.3u, 802.3x CSMA/CD, TCP/IP
Optical indication of operation
Switch power supply;
Link/Act;
PoE Status
~100-240 V; 50/60 Hz; 1,3 A
switched mode power supply PSD520115 52 V DC / 1,15 A/60 W max.
temperature -10°C ÷ 40°C,
relative humidity 5 % - 90 %, no condensation
W=118, H=28, D=95 [+/- 2mm]
Protection class
EN 60950-1:2007
* The given value of 30 W per port is the maximum value. The total power consumption should not exceed 48 W.
2. Installation
2.1. Requirements
The unit should be mounted in confined spaces, in accordance with the 2nd environmental class, with normal relative
humidity (RH=90% maximum, without condensation) and temperature from -10°C to +40°C. Ensure the free flow of air around
the unit. The PSU shall work in a vertical position that guarantees sufficient convectional air-flow through ventilating holes of the
enclosure.
The load balance should be done before installation Switcha. The given value of 30 W per port is the maximum value
referring to a single output. The total power consumption should not exceed 48 W when all PoE ports are being used. The
increased demand for power is particularly evident in the case of cameras with heaters or infrared illuminators - when launching
these features, the power consumption increases rapidly, which may adversely affect the operation of the switch. The device is
designed for a continuous operation and is not equipped with a power-switch. Therefore, an appropriate overload protection in
the power supply circuit should be provided. The electrical system shall be made in accordance with applicable standards and
regulations.
2.2. Installation procedure
1. Connect switch to the PSD520115 52 V DC power supply unit desktop type.
2. Connect the power supply to the 230 V socket.
3. Connect the camera wires to the RJ45 connectors (PoE connectors).
4. Check the optical indication of the switch operation (see Table 3).