SFG64 6-port switch for 4 IP cameras
PL
Edition: 1 from 22.10.2019
Supercedes the edition: ----------
EN**
Features:
Switch 6 ports
4 PoE ports 10/100/1000Mb/s
(data transfer and power supply)
2 ports 10/100/1000Mb/s (UP LINK)
30 W for each PoE port, supports devices complaint
with the IEEE802.3af/at (PoE+) standard
Supports auto-learning and auto-aging of MAC
addresses (2K size)
The PSD 520115 52 V DC/1,15 A/60 W max.
power supply desktop type included
Additional assembly elements
LED indication
warranty 2 year from the production date
Example of use.
1. Technical description
1.1. General description.
SFG64 is a 6-ports PoE switch designed to supply IP cameras operating in IEEE 802.3af/at standard. Automatic
detection of any devices powered in the PoE/PoE+ standard is enabled at the 1 4 ports of the switch. The UP LINK (G1 and
G2) ports is used for connection of another network device via of fiber optic (shall be used GBIC). The LEDs at the front panel
indicate the operation status (description in the table below).
The PoE technology ensures a network connection and reduces installation costs by eliminating the need to supply a
separate power cable for each device. This method allows supplying other network devices, such as IP phone, wireless access
point or router.
2
1.2 Block diagram.
Fig. 1. Block diagram.
1.3. Description of components and connectors.
Table 1. (see Fig.2)
Element no.
(Fig. 2)
Description
[1]
2 x UP LINK port
[2]
4 x PoE port (1÷4)
[3]
Power Socket of the DC
[4]
Additional mounting elements
Fig. 2. The view switch'a.
3
1.4. Technical parameters.
Table 2.
Ports
PoE power supply
Protocols, Standards
Bandwidth
Transmission method
Optical indication of
operation
Power supply
Operating conditions
Dimensions
Additional equipment
Net/gross weight
Protection class
EN 60950-1:2007
Storage temperature
Declarations
* The given value of 30 W per port is the maximum value. The total power consumption should not exceed 48 W.
2. Installation
2.1. Requirements
The unit should be mounted in confined spaces, in accordance with the 2nd environmental class, with normal relative
humidity (RH=90% maximum, without condensation) and temperature from -10°C to +40°C. Ensure the free flow of air around
the unit. The PSU shall work in a vertical position that guarantees sufficient convectional air-flow through ventilating holes of the
enclosure.
The load balance should be done before installation Switcha. The given value of 30 W per port is the maximum value
referring to a single output. The total power consumption should not exceed 48 W. The increased demand for power is
particularly evident in the case of cameras with heaters or infrared illuminators - when launching these features, the power
consumption increases rapidly, which may adversely affect the operation of the switch. The device is designed for a continuous
operation and is not equipped with a power-switch. Therefore, an appropriate overload protection in the power supply circuit
should be provided. The electrical system shall be made in accordance with applicable standards and regulations.
2.2. Installation procedure
1. Connect switch to the PSD520115 52 V DC power supply unit desktop type.
2. Connect the power supply to the 230 V socket.
3. Connect the camera wires to the RJ45 connectors (PoE connectors).
4. Check the optical indication of switch operation (see Table 3).
4
Connection schemes.
5
3. Operation indication.
Table 3. Operation indication
OPTICAL INDICATION OF THE SWITCH's POWER SUPPLY
GREEN LED LIGHT (Power)
Indication of the switch's
power supply
OFF no power supply of the switch
ON power supply on, normal operation
OPTICAL INDICATION AT THE PoE PORTS (1÷4)
GREEN LED LIGHT (PoE)
Indication of the PoE power
supply at the RJ45 ports
OFF- no power supply at the RJ45 port (the device is not connected or not
compliant with the IEEE802.3af/at standard)
ON supply at the RJ45 port
Blinking short-circuit or output overload
YELLOW LED LIGHT (LINK)
The connection status of LAN
devices, 10/100Mb/s
and data transmission
OFF- no connection
ON - the device is connected; 10/100Mb/s
Blinking data transmission
OPTICAL INDICATION AT THE UP LINK PORT
GREEN LED LIGHT (G1)
The connection status of LAN
devices and data transmission
OFF- no connection
ON - the device is connected
Blinking data transmission
YELLOW LED LIGHT (G2)
The connection status of LAN
devices and data transmission
OFF- no connection
ON - the device is connected
Blinking data transmission
WEEE LABEL
Waste electrical and electronic equipment must not be disposed of with normal household waste. According
to the European Union WEEE Directive, waste electrical and electronic equipment should be disposed of
separately from normal household waste.
Pulsar sp. j.
Siedlec 150, 32-744 Łapczyca, Poland
Tel. (+48) 14-610-19-40, Fax. (+48) 14-610-19-50
e-mail: biuro@pulsar.pl, sales@pulsar.pl
http:// www.pulsar.pl, www.zasilacze.pl
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

Pulsar SFG64 Instrukcja obsługi

Kategoria
Routery
Typ
Instrukcja obsługi

w innych językach