Important Safety Instructions: Read Before Installation
INSTALLATION & MAINTENANCE GUIDE
!
www.amplighting.com
–2–
[email protected] • 813.978.3900
Parts Required
–3–
Package Contents
Install Tube
1
This luminaire is intended for installation in accordance with local codes
and the National Electric Code (NEC). Failure to adhere to these codes and
instructions may result in serious injury, property damage and void the
warranty.
These instructions do not intend to cover all variations in installation,
operation maintenance or mounting situations.
1. Make sure the power is turned OFF before installing or servicing this
luminaire.
2. WARNING: risk of electrical shock. Install all luminaires 10 feet (3.05M)
or more from pool, spa or fountain.
3. This luminaire is intended to be used only with a power supply
(transformer) rated maximum of 300 watts (25 AMPS) at 15 volts.
4. Wiring connections must be made with UL listed wire connectors that are
suitable for outdoor use.
5. Position the low voltage wire and wire connector so that it is located
within 6 inches (15.2 cm) from a building structure, a luminaire or
tting.
6. The main low voltage cable is intended for shallow burial - less than 6
inches (152 mm).
7. If additional lengths of low voltage cable are required, please contact
www.amplighting.com or call 1-813-978-3900.
Important Safety Instructions
!
INSTRUCTIONS PERTAINING TO A RISK OF FIRE, OR INJURY TO PERSONS
Lighted lamp is HOT!
WARNING – To reduce the risk of FIRE OR INJURY TO PERSONS.
1. Turn off/unplug and allow to cool before replacing lamp.
2. Lamp gets HOT quickly! Contact only switch/plug when turning on.
3. Do not touch the hot lens, guard or enclosure.
4. Keep lamp away from materials that may burn.
5. Do not touch lamp at any time. Use a soft cloth. Oil from skin may dam-
age lamp.
6. Do not operate the luminaire tting with a missing or damaged shield.
SAVE THESE INSTRUCTIONS
A. (1) PAR36 Lamp (sold
separately)
Product Dimensions
6”
5.5”
8.27”
5.75”
1”
1”
2”
Dig a 6.5” diameter, 8” deep hole in
the ground. Run the main low voltage
supply wires to the hole.
Place 2” of gravel in the bottom of
the hole for proper drainage. Place
the tube inside of the hole and add
the additional gravel around the tube
sides.
Main Low Voltage
Supply Wire
Tube
Gravel
Soil
A. (1) Tube
B. (1) Lamp Holder
C. (1) “U” bracket
A. (2) Screws
B. (2) Nuts
D.
E.
A. (1) Debris Cover (glass +
louvers) (sold separately,
optional)
B.
INSTALLATION & MAINTENANCE GUIDE
–4–
www.amplighting.com
–4–
Install Lamp
3
Install Lamp Holder
2
[email protected] • 813.978.3900
–5–
Install Debris Cover (optional)
4
AMP
®
PAR36 Well Light
AWL-5000-4-P-BK
Wire Connection
5
Attach the lamp holder onto the
“U” bracket by lining up the holes,
then pass the screws through the
holes and secure with the provided
nuts.
“U” Bracket
Lamp Holder
Screw
Nut
Use the PAR36 lamp with the
correct wattage and type marked
on the xture label.
Pass the supply wires through the
center of the lamp holder. Connect
the supply wires to the bottom of
the lamp. Snap the lamp onto the
lamp holder and then push the “U”
bracket with the lamp into the
tube.
CAUTION: Do not exceed maximum
wattage marked on luminaire
label.
NOTE: DO NOT touch lamp with
bare hands. Use soft cloth to
handle lamp.
Tube
Supply Wire
Lamp
“U” Bracket
Lamp Holder
Attach the debris cover onto the
top end of the tube if necessary.
NOTE: Debris cover is not for use
with 50 watt halogen lamps.
Debris Cover
Tube
Strip both leads from the luminaire
pigtail. Using two wire connectors
(sold separately), connect the
leads from the luminaire to the
main supply cable leads.
Pigtail
Wire Connector
Main Supply Cable
Install/Replace Lamp
Please reverse Step 3 - Step 4 to expose the lamp and replace it with the
correct wattage and type marked on the xture label. Reinstall the debris
cover if necessary.
–6–
www.amplighting.com
–6–
[email protected] • 813.978.3900
–7–
IS-AWL-5000-4-P-BK.ver1
Specications and product details subject to change without notice.
© Copyright 2019, AMP
®
Lighting, Lutz FL USA 33549 • All rights reserved.
[email protected] • 813.978.3900
Help Hotline:
1-813-978-3900 • Mon-Fri 9am-6pm (EST)
www.amplighting.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

AMP Lighting PAR36 Well Light Instrukcja instalacji

Typ
Instrukcja instalacji
Ten podręcznik jest również odpowiedni dla