ASSEMBLING THE FIXTU RE (Fig.1)
Fig.1
C
US
Fig.2
FIXTURE
WIRES
BLACKOR
SMOOTH
FIXTURE
WIRES
WHITEOR
RIBBED
FIXTURE
WIRES
GREENOR
BARE
COPPER
(GROUND)
HOUSE
WIRES
BLACK
(HOT)
HOUSE
WIRES
WHITE
(NEUTRAL)
HOUSE
WIRES
GREENOR
BARECOPPER
(GROUND)
1
Shut off power at the fuse box or circuit breaker.Remove the
old fixture including the mounting hardware.
CONNECTING THE WIRES (Fig. 2)
FINISHING THE INSTALLATION (Fig.1)
Your installation is now complete. Return power to the
junction box and test the fixture.
CAUTION/ATTENTION: When handling the fixture, do not
apply pressure to the LEDs. Hold the fixture by the frame
WARNING! SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER
AVERTISSEMENT!COUPER LE COURANT AU NIVEAU DES FUSIBLES OU DO DISJONCTEU
READ AND SAVE THESE INSTRUCTIONS
For LED Wall
INSTALLATION INSTRUCTIONS FOR P1779- 675-L
IMPORTANT: Fixture should be installed by a qualified
electrician to ensure proper wiring and installation.
Dimmable with ELV and/or LED compatible wall
dimmer switches.
W
A
T
B
C
D
G
F
A
B
C
D
T
V
W
2 Carefully remove the fixture from the carton and check that all parts
areincluded as show in Figure 1. Unscrew ( G ) to remove the
mounting plate ( A ) from the canopy ( F),unscrew hex nut to take
the square plate off.
3 Position mounting plate(A) on the wall ,and mark the location of
the dry wall anchors(W).Pre-drill the holes for the dry wall anchors ,
Insert the dry wall anchors(W) into the wall ,Attach the mounting
plate (A) to the junction box using the mounting
screws(B,size 8#-32N 1/2').The side of the mounting plate
marked “GND” must face out.Place the wood screw (T) through
the slot hole into the dry wall anchor(W) to secure the mounting
4 Pass the black/white and bare copper wires from the hole of the
square plate (V), and let the square plate rest on the canopy (F).
Connect the electrical wire as shown in figure 2,making sure that
all wire connectors are secured. If your junction box has a ground
wire (green or bare copper),connect the ground wire from the
fixture to it. Otherwise connect fixture ground wire (C) directly to
the mounting plate using the green screw (D)provided. Tuck the
wire connections neatly into the ceiling junction box as you hold
the canopy towards the wall.
5. Push the square plate (V) to the studs to fix with the hex nuts.
) Fix the canopy(F) into the mounting plate (A with finial(G).
3 Position mounting plate(A) on the wall ,and mark the
location of the dry wall anchors(W).Pre-drill the holes
for the dry wall anchors ,Insert the dry wall anchors(W)
into the wall ,Attach the mounting plate (A) to the
junction box using the mounting screws
(B,size 8#-32N 1/2').The side of the mounting plate
marked “GND” must face out.Place the wood screw
(T) through the slot hole into the dry wall anchor(W) to
secure the mounting
2 Carefully remove the fixture from the carton and check
that all parts areincluded as show in Figure 1.
Unscrew ( G ) to remove the mounting plate ( A ) from
the canopy ( F),unscrew hex nut to take the square
plate off.
4 Pass the black/white and bare copper wires from the
hole of the square plate (V), and let the square plate
rest on the canopy (F).Connect the electrical wire as
shown in figure 2,making sure that all wire connectors
are secured. If your junction box has a ground wire
(green or bare copper),connect the ground wire from
the fixture to it. Otherwise connect fixture ground wire
(C) directly to the mounting plate using the green screw
(D)provided. Tuck the wire connections neatly into the
ceiling junction box as you hold the canopy towards the
 wall.
5 Push the square plate (V) to the studs to fix with the hex
nuts. )Fix the canopy(F) into the mounting plate (A with
screw(G).