Novus NVIP-2D-6402 (NVIP-2DN3038D/IR-1P) Instrukcja obsługi

Kategoria
Kamery ochrony
Typ
Instrukcja obsługi
User s ma n ual
(shor t for m )
NVIP-2D-6402
NVIP-2D-6402 - Users manual (short form) ver 1.0.
All rights reserved © AAT Holding S.A.
2
IMPORTANT SAFEGUARDS AND WARNINGS
EMC (2004/108/EC) and LVD (2006/95/EC ) Directives
CE Marking
Our products are manufactured to comply with requirements of the following directives and national
regulations implementing the directives:
Electromagnetic compatibility EMC 2004/108/EC.
Low voltage LVD 2006/95/EC with further amendment. The Directive applies to electrical
equipment designed for use with a voltage rating of between 50VAC and 1000VAC as well as
75VDC and 1500VDC.
WEEE Directive 2012/19/EU
Information on Disposal for Users of Waste Electrical and Electronic Equipment
This appliance is marked according to the European 1000VAC Directive on Waste Electrical and
Electronic Equipment (2012/19/EU) and further amendments. By ensuring this product is disposed of
correctly, you will help to prevent potential negative consequences for the environment and human
health, which could otherwise be caused by inappropriate waste handling of this product.
The symbol on the product, or the documents accompanying the product, indicates that this appliance may not be
treated as household waste. It shall be handed over to the applicable collection point for used up electrical and
electronic equipment for recycling purpose. For more information about recycling of this product, please contact
your local authorities, your household waste disposal service or the shop where you purchased the product.
RoHS Directive 2011/65/EU
Out of concern for human health protection and friendly environment, we assure that our products falling under
RoHS Directive regulations, regarding the restriction of the use of hazardous substances in electrical and
electronic equipment, have been designed and manufactured in compliance with the above mentioned
regulations. Simultaneously, we claim that our products have been tested and do not contain
hazardous substances whose exceeding limits could have negative impact on human health or natural
environment
Information
The device, as a part of professional CCTV system used for surveillance and control, is not designed for self
installation in households by individuals without technical knowledge.
Excluding of responsibility in case of damaging data on a disk or other devices:
The manufacturer does not bear any responsibility in case of damaging or losing data on a disk or other devices
during device operation.
WARNING!
PRIOR TO UNDERTAKING ANY ACTION THAT IS NOT DESCRIBED FOR THE GIVEN PRODUCT IN
USERS MANUAL AND OTHER DOCUMENTS DELIVERED WITH THE PRODUCT, OR IF IT DOES
NOT ARISE FROM THE USUAL APPLICATION OF THE PRODUCT, MANUFACTURER MUST BE
CONTACTED UNDER THE RIGOR OF EXCLUDING THE MANUFACTURERS RESPONSIBILITY FOR
THE RESULTS OF SUCH AN ACTION.
NVIP-2D-6402 - Users manual (short form) ver 1.0.
All rights reserved © AAT Holding S.A.
3
IMPORTANT SAFEGUARDS AND WARNINGS
WARNING!
THE KNOWLEDGE OF THIS MANUAL IS AN INDESPENSIBLE CONDITION OF A PROPER
DEVICE OPERATION. YOU ARE KINDLY REQUSTED TO FAMILIRIZE YOURSELF WITH
THE MANUAL PRIOR TO INSTALLATION AND FURTHER DEVICE OPERATION.
WARNING!
USER IS NOT ALLOWED TO DISASSEMBLE THE CASING AS THERE ARE NO USER
-SERVICEABLE PARTS INSIDE THIS UNIT. ONLY AUTHORIZED SERVICE PERSONNEL
MAY OPEN THE UNIT
INSTALLATION AND SERVICING SHOULD ONLY BE DONE BY QUALIFIED SERVICE
PERSONNEL AND SHOULD CONFORM TO ALL LOCAL REGULATIONS
1. Prior to undertaking any action please consult the following manual and read all the safety and operating
instructions before starting the device.
2. Please keep this manual for the lifespan of the device in case referring to the contents of this manual is
necessary;
3. All the safety precautions referred to in this manual should be strictly followed, as they have a direct
influence on users safety and durability and reliability of the device;
4. All actions conducted by the servicemen and users must be accomplished in accordance with the users
manual;
5. The device should be disconnected from power sources during maintenance procedures;
6. Usage of additional devices and components neither provided nor recommended by the producer is
forbidden;
7. You are not allowed to use the camera in high humidity environment (i.e. close to swimming pools, bath tubs,
damp basements);
8. Mounting the device in places where proper ventilation cannot be provided (e. g. closed lockers etc.) is not
recommended since it may lead to heat build-up and damaging the device itself as a consequence;
9. Mounting the camera on unstable surface or using not recommended mounts is forbidden. Improperly
mounted camera may cause a fatal accident or may be seriously damaged itself. The camera must be mounted
by qualified personnel with proper authorization, in accordance with this users manual.
10. Device should be supplied only from a power sources whose parameters are in accordance with those
specified by the producer in the camera technical datasheet. Therefore, it is forbidden to supply the camera
from a power sources with unknown parameters, unstable or not meeting producers requirements;
Due to the product being constantly enhanced and optimized, certain parameters and functions
described in the manual in question may change without further notice.
We strongly suggest visiting the www.novuscctv.com website in order to access the newest full manual
NVIP-2D-6402 - Users manual (short form) ver 1.0.
All rights reserved © AAT Holding S.A.
4
TABLE OF CONTENTS ..................................................................................................... 4
1. FOREWORD INFORMATION ................................................................................... ..5
1.1. General characteristics ......................................................................................... 5
1.2. Technical specification .................................................................................... ...6
1.3. Camera dimension ........................................................................................... ...7
1.4. Package contents ............................................................................................... ...7
2. START-UP AND INITIAL IP CAMERA CONFIGURATION ................................. 8
2.1. Description of connectors and control tools ........................................................ 8
2.2. Zoom and focus adjustment ................................................................................. 9
2.3. Connecting ethernet cable ................................................................................. 10
2.4. Cameras mounting ............................................................................................. 10
2.5. Starting the IP camera ........................................................................................ 11
2.6. Initial configuration via the web browser .......................................................... 12
3. NETWORK CONNECTION UTILIZING WEB BROSWER ................................ 13
3.1. Recommended PC specification for web browser ............................................. 13
3.2. Connection with IP camera via web browser ..................................................... 13
4. USING AND CONFIGURING ..................................................................................... 15
4.1. Displaying live pictures. ..................................................................................... 15
5. ELECTRIC CONNECTORS AND ACCESORIES ................................................. 16
5.1. Connecting power supply to the camera. .......................................................... 16
5.2. Connecting alarm input and output .................................................................... 16
5.3. SD card installation ........................................................................................... 17
6. RESTORING FACTORY DEFAULTS ..................................................................... 18
6.1. Restoring software factory defaults via web browser ........................................ 18
6.2. Restoring software factory defaults via NMSiptool ........................................... 18
6.3. Restoring hardware factory defaults in IP cameras ........................................... 19
TABLE OF CONTENTS
NVIP-2D-6402 - Users manual (short form) ver 1.0.
All rights reserved © AAT Holding S.A.
5
1. FOREWORD INFORMATION
1.1. General Characteristics
Imager resolution: 2 megapixels
Mechanical IR cut filter, IR operation capability
Min. Illumination from 0 lx with IR LED on
Wide Dynamic Range (WDR) for enhanced image quality in diverse light conditions
Digital Noise Reduction (DNR)
Lens type: varifocal, f=2.8-12 mm/F=1.4
Built-in LED illuminator: 30 pcs LED
Built-in webserver: camera configuration through the website
Compression: H.264, H.265/ MJPEG
Max video processing resolution: 1920 x 1080
Multi streaming: compression, resolution, speed and quality defined individually for each video
stream
ROI functions
Motion detection
Private Zones
RTSP protocol support for video transmission
Schedule
Micro SD card up to 128 GB
Audio input
Audio output
Bulid-in microphone
BNC output
Alarm input (NO/NC)
Alarm Output
Wide range of responses to alarm events: e-mail with attachment, saving file on FTP server, save
file on SD card.
Software: NMS (NOVUS MANAGEMENT SYSTEM) for video recording, live monitoring,
playback and remote IP devices administration
Video Content Analysis (VCA):
Exception
Line Crossing
Intrusion
Power supply: 12VDC, PoE (Power over Ethernet)
FOREWORD INFORMATION
NVIP-2D-6402 - Users manual (short form) ver 1.0.
All rights reserved © AAT Holding S.A.
6
1.2. Technical specification
FOREWORD INFORMATION
IMAGE
Image Sensor 2 MPX CMOS sensor 1/2.7” APTINA
Number of Effective Pixels 1920 (H) x 1080 (V)
Min. Illumination
0.07 lx/F1.4 - color mode,
0 lx (IR on) - B/W mode
Electronic Shutter auto: 1/25 s ~ 1/100000 s
Wide Dynamic Range (WDR) yes (double scan sensor), 120dB
Digital Noise Reduction (DNR) 3D
Defog Function (F-DNR) yes
LENS
Lens Type varifocal, f=2.8 ~ 12 mm/F1.4
DAY/NIGHT
Switching Type mechanical IR cut filter
Switching Mode auto, manual, time
Switching Level Adjustment yes
Switching Schedule yes
Visible Light Sensor yes
NETWORK
Stream Resolution 1920 x 1080 (Full HD), 1280 x 720 (HD), 640 x 480 (VGA), 320 x 240 (QVGA)
Frame Rate 30 fps for 1920 x 1080 (Full HD) and lower resolutions
Multistreaming Mode 3 streams
Video/Audio Compression H.264, H.265, MJPEG/G.711
Number of Simultaneous Connections max. 4
Bandwidth 9 Mb/s in total
Network Protocols Support TCP/IP, UDP, FTP, DHCP, DDNS, NTP, RTSP, UPnP, PPPoE, SMTP
ONVIF Protocol Support Profile S (ONVIF 2.3)
Camera Configuration
from Internet Explorer browser
languages: Polish, English, Russian, and others
Compatible Software NMS
OTHER FUNCTIONS
Privacy Zones 4
Motion Detection yes
Region of interest (ROI) 3
Video Content Analysis (VCA) tamper, line cross, zone entrance
Image Processing 180˚ image rotation, sharpening, mirror effect, corridor mode
Prealarm/Postalarm -/up to 120 s
System Reaction to Alarm Events
e-mail with attachment, saving file on FTP server, saving file on SD card, alarm output activa-
tion
IR LED
LED Number 30
Range 30 m
Angle 90°
INTERFACES
Video Output BNC, 1.0 Vp-p, 75 Ohm
Audio Input/Output 1 x Jack (3.5 mm)/1 x Jack (3.5 mm) additionally built-in: microphone
Alarm Input/Output 1 (NO/NC)/1 relay type
Network Interface 1 x Ethernet - RJ-45 interface, 10/100 Mbit/s
Memory Card Slot microSD - capacity up to 128GB
INSTALLATION PARAMETERS
Dimensions (mm) 122 (Ф) x 96 (H)
Weight 0.45 kg
Enclosure plastic, white
Power Supply PoE, 12 VDC
Power Consumption 2.5 W,6 W (IR on)
Operating Temperature -20°C ~ 50°C
NVIP-2D-6402 - Users manual (short form) ver 1.0.
All rights reserved © AAT Holding S.A.
7
FOREWORD INFORMATION
1.3. Camera dimensions
1.4. Package contents
After you open the package make sure that the following elements are inside:
IP camera
Accessories bag
Short version of users manual
If any of this elements has been damaged during transport, pack all the elements back into the original
box and contact your supplier for further assistance.
CAUTION!
If the device was brought from a location with lower temperature, please wait until it reaches
the temperature of location it is currently in. Turning the device on immediately after bringing it
from a location with lower ambient temperature is forbidden, as the condensing water vapour
may cause short-circuits and damage the device as a result.
Before starting the device familiarize yourself with the description and the role of particular
inputs, outputs and adjusting elements that the device is equipped with.
NVIP-2D-6402 - Users manual (short form) ver 1.0.
All rights reserved © AAT Holding S.A.
8
START-UP AND INITIAL IP CAMERA CONFIGURATION
2.FOREWORD INFORMATION
2.1 Description of connectors and control tools
1. BNC video output
2. Audio output
3. Audio input
4. Power supply 12VDC
5. 100 Mb/s Ethernet port (RJ-45 connector)
6. Alarm Connectors
1. Alarm COM
2. Alarm OPEN
3. Alarm INA
4. Alarm GND
7. RS-485 conectors
WARNING! To get access to above ports it is required to remove camera dome cover.
1. Light sensor
2. Reset button
3. microSD card slot
4. Buldi in microphone
5. IR LED
1
2
3
4
5
5
1
2
4
3
6
7
NVIP-2D-6402 - Users manual (short form) ver 1.0.
All rights reserved © AAT Holding S.A.
9
2.2 Zoom and focus adjustment
1. Remove dome cover by turning it
counterclockwise
2. Adjust zoom and focus.
3. Close camera by turning dome clockwise
2.3. Connecting ethernet cable
To maintain tightness of ethernet cable connection, please follow instruction below:
1. Loosen the nut (a) from the main element (b).
2. Run power cable (without RJ-45 connector) though both elements. Then crimp the cable with RJ-45
connector.
3. Connect the cable to the hermetic connector (c), screw main cover (b), then screw the nut (a).
START-UP AND INITIAL IP CAMERA CONFIGURATION
Zoom
Focus
a
b
a
b
c
NVIP-2D-6402 - Users manual (short form) ver 1.0.
All rights reserved © AAT Holding S.A.
10
2.4. Connecting power supply to the camera.
Camera can be supplied using external power supply unit corresponding with the camera parameters or
by using RJ45 network socket and PoE (802.3at Type 1 ) power supply unit.
Information:
Power supply adapter is not included. Please use power adapter with parameters specified in users
manual.
CAUTION:
Do not use power supplies and POE adapters not compatible with IEEE 802.3af standard!
Damage resulting from the use of improper power supply is not covered under warranty!
In order to provide protection against voltage surges/lightning strikes, usage of appropriate surge
protectors is advised. Any damages resulting from surges are not eligible for service repairs.
2.4. Camera mounting
1. Remove dome cover by turning it counterclockwise
2. Put assembly template of the camera to the desired
mounting surface, and mark drilling holes.
3. Drill mounting, cable and heat removal holes (1) in
previously selected points.
4. Mount the camera base using included screws on smooth
surface
5. Adjust the position of the camera module.
6. Adjust focal length and focus using proper levers.
7. Put on the camera cover again, by turning it clockwise.
START-UP AND INITIAL IP CAMERA CONFIGURATION
12 VDC +
12 VDC -
Camera 12 VDC power supply
1
NVIP-2D-6402 - Users manual (short form) ver 1.0.
All rights reserved © AAT Holding S.A.
11
2.5. Starting the IP camera
To run NOVUS IP camera you have to connect ethernet cable between camera and network switch.
To power it up you can connect it directly via power supply adapter with parameters compatible with
camera power supply specification, or camera can be powered with PoE (IEEE 802.3af ) compatible
switch.
After connecting power supply it takes about 30 seconds to start camera. Then You can proceed to
connect to the camera via web browser.
The recommended way to start an IP camera and perform its configuration is a connection directly
to the network switch which is not connected to other devices. To obtain further information about
network configuration parameters (IP address, gateway, network mask, etc.) please contact your
network administrator.
Connection utilising network switch with PoE support
Connection utilising external power supply and network switch
START-UP AND INITIAL CAMERA CONFIGURATION
IP Camera
Network transmission
Network Switch
Computer
Network transmission
Power supply and
network transmission
Computer
IP Camera
Network Switch
PoE
Network transmission
NVIP-2D-6402 - Users manual (short form) ver 1.0.
All rights reserved © AAT Holding S.A.
12
Connection utilising external power supply directly to the computer
Information:
Power supply adapter is not included. Please use power adapter with parameters specified in user s
manual.
Caution:
In order to provide protection against voltage surges/lightning strikes, usage of appropriate surge
protectors is advised. Any damages resulting from surges are not eligible for service repairs.
2.6. Initial configuration via the web browser
The default network settings for 6000 IP camera series are :
1. IP address= 192.168.1.200
2. Network mask - 255.255.255.0
3. Gateway - 192.168.1.1
4. User name - root
5. Password - pass
Knowing the cameras IP address you need to appropriately set PC IP address, so the two devices can
operate in one network subnet ( e.g. for IP 192.168.1.1, appropriate address for the camera ranges from
192.168.1.2 to 192.168.1.254, for example 192.168.1.60). It is not allowed to set the same addresses for
camera and PC computer
You can either set a network configuration (IP address, gateway, net mask, etc.) of NOVUS IP camera
yourself or select DHCP mode (DHCP server is required in this method in target network) by using
web browser or by NMS software. When you use DHCP server check IP address lease and its linking
with camera MAC address to avoid changing or losing IP address during device operation or network/
DHCP server breakdown. You have to remember to use a new camera IP address after changing
network parameters.
After network setting configuration has been done, the camera can be connected to a target network.
START-UP AND INITIAL CAMERA CONFIGURATION
IP Camera
Network transmission - cross over cable
Computer
NVIP-2D-6402 - Users manual (short form) ver 1.0.
All rights reserved © AAT Holding S.A.
13
3. NETWORK CONNECTION UTILIZING WEB BROSWER
3.1. Recommended PC specification for web browser connections
Requirements below apply to connection with an IP camera, assuming smooth image display
in 1920x1080 resolution and 30 fps speed.
1. CPU Intel Core i3 3 GHz or better
2. RAM Memory min. 4 GB
3. Graphic card NVIDIA GeForce 512 MB or equivalent
4. OS Windows 7 / 8 / 8.1 / 10
5. Network card 100/1000 Mb/s
3.2. Connection with IP camera via web browser
You have to enter camera IP address in the address bar. When you connect to the camera, web browser
will download the applet for displaying images from the camera. In Internet Explorer it may be
necessary to accept an ActiveX control. To do this, click the right mouse button on the message, select
"Install Active X control" and then click Install. After successfully NetIPCamera plug in downloading
run and install it on a computer.
NETWORK CONNECTION UTILIZING WEB BROWSER
NVIP-2D-6402 - Users manual (short form) ver 1.0.
All rights reserved © AAT Holding S.A.
14
If the installation fails, changing security settings for the IE browser is required. In order to do that,
please choose: Tools > Internet options > Security tab > Custom level and:
Under Download unsigned ActiveX controls - select either Enable or Prompt
Under Initialize and script ActiveX controls not marked as safe - select Enable or Prompt
You can also add the cameras IP address to trusted zone and set lowest security level for it.
In addition, when working in Windows / 7 / 8 / 8.1 / 10 the ActiveX applet may be blocked by
Windows Defender or User account control. In such case you should allow to run this applet, or simply
disable these functions.
After successful installation login window will be displayed. Default user is root and default password
is pass. For safety reasons, it is recommended to change default user name and password.
WARNING !!! If user forgets login and/or password for IP Camera, it is required to sent
IP Camera back to supplier. In this case, it is not possible for user to restore IP Camera factory
defaults on his own.
NETWORK CONNECTION UTILIZING WEB BROWSER
NVIP-2D-6402 - Users manual (short form) ver 1.0.
All rights reserved © AAT Holding S.A.
15
4. USING AND CONFIGURING
4.1 The Remote Preview Interface
1. View settings
Original size Automatic Size
Fill screen Full Screen
2. Camera functions
Live View On/Off Take a snapshoot Zoom In/out
On/Off Sound Record Video
3. Motion detection
Motion detection
4. Camera buffer
There is three possible options of view: REAL-TIME, BALANCED, FLUENT
USING AND CONFIGURING
1
2
3
4
Color ab. Clarity ab. Scene change
NVIP-2D-6402 - Users manual (short form) ver 1.0.
All rights reserved © AAT Holding S.A.
16
ELECTRIC ACCESORIES
5. ELECTRIC ACCESORIES
5.1. Connecting alarm inputs/outputs.
Alarm input
Alarm input connection
Alarm output
Camera alarm output is an relay output type.
Alarm output electric connections
Alarm
input (-)
Alarm GND
IP Camera
Alarm
input (+)
Alarm INA
Switch/sensor
Alarm
Output (-)
Alarm COM
Alarm
Output (+)
Alarm NO
Indicator
power
supply
Indicator
IP Camera
NVIP-2D-6402 - Users manual (short form) ver 1.0.
All rights reserved © AAT Holding S.A.
17
ELECTRIC ACCESORIES
5.2 SD card installation
Camera supports microSD/SDHC cards up to a maximum size of 128GB. In order to install the card
properly, please follow the instructions below:
Turn the camera off
Remove dome cover by turning it counterclockwise
Mount micro SD card in the socket located at the cameras base, according to the picture:
Mount camera cover dome
Turn the camera on
Check the micro SD card by checking its capacity in the Config-> System -> Store tab.
5.3 Connecting Cameras Audio
Line in of camera allow to connect external Microphone (with own power supply)
microSD card slot
MICROPHONE
POWER
NVIP-2D-6402 - Users manual (short form) ver 1.0.
All rights reserved © AAT Holding S.A.
18
RESTORING FACTORY DEFAULTS
6. RESTORING FACTORY DEFAULTS
Camera allow to restore defaults via:
software (via web browser)
software (via NMSiptool)
Hardware (using reset button)
6.1. Restoring factory defaults by software means
User can restore default settings of the IP camera except network settings. To restore to default settings
go to: Advanced Config -> Config Backup & Restore tab. Process of restoring takes about two
minutes.
6.2. Restoring factory defaults by software means (NMSiptool level)
NMSip (version 1.39 or later) allows to restore factory defaults. To restore settings find camera via
NMSiptool, click right mouse button and choose Restore default configuration”. Next, within 30
seconds, it is required to turn the camera power off and on.
NVIP-2D-6402 - Users manual (short form) ver 1.0.
All rights reserved © AAT Holding S.A.
19
RESTORING FACTORY DEFAULTS
6.3. Restoring factory defaults by hardware means
In order to restore factory defaults for the camera please follow the instructions:
Remove dome cover by turning it counterclockwise
Press the RESET button and hold on for 10 seconds
Release button
Mount camera cover dome
Log on after approx. 30 seconds using default IP address (http://192.168.1.200) and default user
name (root) and password (pass)
Reset
2019-02-13 MO
AAT Holding S.A., 431 Pulawska St., 02-801 Warsaw, Poland
tel.: +4822 546 07 00, fax: +4822 546 07 59
www.novuscctv.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40

Novus NVIP-2D-6402 (NVIP-2DN3038D/IR-1P) Instrukcja obsługi

Kategoria
Kamery ochrony
Typ
Instrukcja obsługi