Planet IPOE-470 Instrukcja obsługi

Kategoria
Przełączniki sieciowe
Typ
Instrukcja obsługi
Industrial 4-port Multi-Gigabit 802.3bt PoE++
Injector Hub
IPOE-470
Users Manual
Table of Contents
1. Packet Contents ................................................................................... 3
2. ProductSpecications ........................................................................... 4
3. Hardware Introduction .......................................................................... 6
3.1 Device Front Panel ......................................................................... 6
3.2 DIP Switch Information .................................................................. 7
3.3 Device Top Panel ........................................................................... 8
3.4 Wiring the Power Inputs ................................................................. 8
3.5 Grounding the Device ................................................................... 10
4. Installation ........................................................................................ 11
4.1 DIN-rail Mounting Installation ....................................................... 11
4.2 Wall-mount Plate Mounting ........................................................... 12
5. Three-View Diagram ........................................................................... 13
Customer Support .................................................................................... 14
3
1. Packet Contents
Thank you for purchasing PLANET Industrial 4-port Multi-Gigabit 802.3bt
PoE++ Injector Hub, IPOE-470.
Open the box of the Industrial PoE++ Injector Hub and carefully unpack it.
The box should contain the following items:
Industrial PoE++ Injector Hub x 1 Quick Start QR Code Sheet x 1
Let’s get started with your PLANET product
IPOE-470
EN Please scan the QR code to browse our online User’s Manual or Quick
Installation Guide and follow the instructions to complete the setup.
User's Manual
DE
Bitte scannen Sie den QR Code sie werden per Browser zur
Bedienungsanleitung oder Schnellanleitung weiter geleitet. Folgen Sie den
Anweisungen um die Installation abzuschließen.
FR
Veuillez scanner le code QR pour obtenir notre Notice d’Utilisation en
ligne ou notre Guide d’Installation Rapide et suivez les instructions pour
compléter la conguration
ES
Escanee el código QR para encontrar el Manual del Usuario en línea o
la Guía de Instalación Rápida y siga las instrucciones para completar la
conguración.
IT Scansiona il codice QR per consultare online il Manuale utente o la Guida di
installazione rapida e segui le istruzioni per completare la congurazione.
PT Por favor, escaneie o QR code para navegar no Manual do Usuário ou Guia
de Instalação Rápida. Siga as instruções para completar a conguração.
PL
Zeskanuj kod QR, aby otworzyć naszą internetową instrukcję obsługi
lub instrukcję szybkiej instalacji. Postępuj zgodnie z instrukcjami, aby
zakończyć poprawną kongurację.
RU
One word modify: Отсканируйте QR-код, чтобы просмотреть наше
онлайн-руководство пользователя или руководство по быстрой
настройке, и следуйте инструкциям для завершения настройки
RO Te rugam sa scanezi codul QR, pentru a descarca User’s Manual sau Quick
Installation Guide si a urmari instructiunile necesare in nalizarea instalarii
AR
Need more help?
PLANET online FAQs:
http://www.planet.com.tw/en/support/faq
Technical Support: [email protected]
Copyright © PLANET Technology Corp. 2023.
Contents are subject to revision without prior notice.
PLANET is a registered trademark of PLANET Technology Corp.
All other trademarks belong to their respective owners.
Part No. 2360-AH8060-001
DIN-rail Kit x 1 RJ45 Dust Caps x 8 Wall-mount Kit x 1
If any of these are missing or damaged, please contact your dealer
immediately.
4
2.ProductSpecications
Model IPOE-470
HardwareSpecications
Copper Ports
4-pair 10/100/1000/2500BASE-T RJ45
Data input (port 1 to port 4)
Data + PoE output (port 1 to port 4)
Connector
Removable 6-pin terminal block
Pins 1 and 2 for Power 1
Pins 5 and 6 for Power 2
Pins 4 and 4 for fault alarm
Data Rate 10/100/1000/2500Mbps
Power Requirements 48~54V DC, redundant power
with reverse polarity protection
Power Consumption
(Ethernet Full Loading)
System ON without loading
52V DC: 2.08 watts/7.1BTU
54V DC: 2.16 watts/7.4BTU
Full loading
52V DC: 250.6 watts/855BTU
54V DC: 251.1 watts/856.7BTU
DIP Switch
Per PoE port
OFF: BT -- 802.3bt PoE++ 95W PoE output
ON: Legacy -- 60w PoE output
Dimensions 50 x 87.8 x 135 mm (W x D x H)
Weight 544g
Enclosure IP30 metal case
Installation DIN-rail kit and wall-mount kit
LED Indicator
System:
Power 1 (Green)
Power 2 (Green)
Alarm (Red)
PoE Usage:
80W/160W/240W (Amber)
802.3bt PoE++ Port:
PoE-in-use x 1 (Amber)
ESD Protection 6KV
5
Surge Protection 6KV
Network Cable
Twisted-pair cable up to 100 meters (328ft)
10BASE-T: 4-pair UTP Cat. 3, 4, 5, 5e, 6
100BASE-TX: 4-pair UTP Cat. 5, 5e, 6
1000BASE-T: 4-pair UTP Cat. 5e, 6
Power over Ethernet
PoE Standard IEEE 802.3bt PoE++, 4-pair type 4 PSE
Backward compatible with IEEE 802.3at PoE+ PSE
PoE Power Supply Type 802.3bt PoE++ End-span + Mid-span
802.3at PoE+ End-span/Mid-span
Power Pin Assignment
Pair 1 End-span: 1/2(-), 3/6(+)
Pair 2 Mid-span: 4/5(+), 7/8(-)
802.3bt: 1/2(-), 3/6(+), 4/5(+), 7/8(-)
PoE Power Output
Max. 95 watts to 802.3bt PoE++ PD
Max. 60 watts to Legacy-powered PD
Max. 36 watts to 802.3at PoE+ PD
PoE Power Budget
(max.)
240W@52V DC input
120W@48V DC input
Number of devices that
can be powered 4
Standards Conformance
Regulatory Compliance FCC Part 15 Class A, CE
Stability Testing
IEC 60068-2-32 (free fall)
IEC 60068-2-27 (shock)
IEC 60068-2-6 (vibration)
Standards Compliance
IEEE 802.3 Ethernet
IEEE 802.3u Fast Ethernet
IEEE 802.3ab Gigabit Ethernet
IEEE 802.3at Power over Ethernet Plus
IEEE 802.3bt Power over Ethernet Plus Plus
Environment
Temperature Operating: -40~75 degrees C
Storage: -40~75 degrees C
Humidity Operating: 5~90% (non-condensing)
Storage: 5~90% (non-condensing)
6
3. Hardware Introduction
3.1 Device Front Panel
The front panels of the Industrial PoE++ Injector Hubs consist of Ethernet
interfaces and LED indicators.
Front View
P1 P2 Alarm
80W 160W 240W
PoE
Usage
1
DATA
2
3
4
IPOE-470
DATA & PWR
Legacy
ON
BT
OFF PoE
Mode
DIPON
1
2
3
4
Figure 1: IPOE-470 Front View
System LEDs
LED Color Function
P1 Green Lights to indicate DC power input 1 has power.
P2 Green Lights to indicate DC power input 2 has power.
Alarm Red Lights to indicate either power 1 or power 2 has no power.
PoE
Usage Amber
80W, 160W, 240W
Lights to indicate the system consumes over 80-/160-
/240-watt PoE power budget.
Blinks to indicate the system consumes less than
80-/160-/240-watt PoE power budget.
7
802.3bt PoE++ TP Interface LEDs
LED Color Function
802.3bt
PoE++
PoE-in-Use
Amber
Lights to indicate that the port is providing PoE in-line
power to remote powered device.
OtoindicatethattheportisnotprovidingPoE
in-line power to remote powered device.
3.2 DIP Switch Information
To meet the demand of various powered devices consuming stable PoE power,
the PoE++ Injector Hub provides one DIP switch for three PoE operation mode
options as shown in the following table.
P1 P2 Alarm
80W 160W 240W
PoE
Usage
Legacy
ON
BT
OFF PoE
Mode
DIPON
1
2
3
4
PoE Mode Description
802.3bt
(Default)
The Standard mode is to provide power to the PD device that
follows the IEEE 802.3af/at/bt standard.
Legacy
The Legacy mode supports Ultra PoE. It is to provide power to
the PD devices that do not fully follow the IEEE 802.3af/at/bt
standard.
The IPOE-470 series also supports Force Power Mode in the
Legacy mode. If the output power of IPOE-470 series in the
Legacy Mode is less than 1 watt for 20 seconds, the Force Mode
will be enabled for 2 seconds. If the loading is still less than 1
watt, the Legacy Mode will be enabled again.
8
To prevent the devices from damage, please make sure the
remote devices support either the Legacy or Force Mode before
turning the DIP switch to the Legacy Mode.
Adjust the DIP switch to the desired mode before powering on
the IPOE-470 series.
3.3 Device Top Panel
The upper panels of the Industrial PoE++ Injector Hubs consist of one terminal
block connector within two power inputs.
Max. Fault Alarm Loading: 24V, 1A
V1+ V2+
PWR1 PWR2Alarm
DC Input:
48-54V , 5A max.
1 2 3 4 5 6
Figure 2: IPOE-470 Top View
3.4 Wiring the Power Inputs
The terminal block connector on the top panel of Industrial PoE++ Injector
Hub is used for two DC redundant power inputs. Please follow the steps below
to insert the power wire.
When performing any of the procedures like inserting the wires
or tightening the wire-clamp screws, make sure the power is
OFF to prevent from getting an electric shock.
9
1. Insert positive and negative DC power wires into contacts 1 and 2 for
POWER 1, or contacts 5 and 6 for POWER 2.
Max. Fault Alarm Loading: 24V, 1A
V1+ V2+
PWR1 PWR2Alarm
DC Input:
48-54V , 5A max.
1 2 3 4 5 6
2. Tighten the wire-clamp screws for preventing the wires from loosening.
123456
V1+ V1- V2+ V2-
Power 1 Alarm Power 2
Figure 3: PWR1 & PWR2 pins of terminal block.
PWR1 and PWR2 must provide the same DC voltage while
operating with dual power input.
The wire gauge for the terminal block should be in the range
between 12 and 24 AWG.
10
3.5 Grounding the Device
Users MUST complete grounding wired with the device; otherwise, a sudden
lightning could cause fatal damage to the device.
Max. Fault Alarm Loading: 24V, 1A
V1+ V2+
PWR1 PWR2Alarm
DC Input:
48-54V , 5A max.
1 2 3 4 5 6
Earth Ground
EMD (Lightning) DAMAGE IS NOT COVERED UNDER WARRANTY.
11
4. Installation
This section guides you to installing the Industrial PoE++ Injector Hub on the
DIN rail and wall. Please read this chapter completely before continuing.
In the installation steps below, this manual uses PLANET Indus-
trial Gigabit Switch as an example. The steps for PLANET Indus-
trial Slim-type Switch, Industrial Media/Serial Converter and
Industrial PoE devices are similar.
4.1 DIN-rail Mounting Installation
1
2
12
4.2 Wall-mount Plate Mounting
You must use the screws supplied with the wall-mounting
brackets. Damage caused to the parts by using incorrect screws
would invalidate your warranty.
13
5. Three-View Diagram
IPOE-470
50.00
135.00
87.80
97.10
48.8046.50 39.70
87.80
53.50 53.50
18.00
15.20
9.20
163.00
40.00
50.00
28.00
18.00
Max. Fault Alarm Loading: 24V, 1A
V1+ V2+
PWR1 PWR2Alarm
DC Input:
48-54V , 5A max.
P1 P2 Alarm
80W 160W 240W
PoE
Usage
1
DATA
2
3
4
IPOE-470
DATA & PWR
Legacy
ON
BT
OFF PoE
Mode
DIPON
1
2
3
4
Top View
Side View Front View
Mounting Kit
Mounting Kit
DIN-Rail Kit
Side View Rear View
Unit: mm
Bottom View
1 2 3 4 5 6
Figure 4: IPOE-470 Three-View Diagram
14
Customer Support
Thank you for purchasing PLANET products. You can browse our online FAQ
resource on PLANET web site rst to check if it could solve your issue. If you
need more support information, please contact PLANET support team.
PLANET online FAQs :
http://www.planet.com.tw/en/support/faq
Support team mail address:
Copyright © PLANET Technology Corp. 2023.
Contents are subject to revision without prior notice.
PLANET is a registered trademark of PLANET Technology Corp.
All other trademarks belong to their respective owners.
15
FCC Warning
This device has been tested and found to comply with the limits for a Class
A digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the Instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the user
will be required to correct the interference at his own expense.
CE Mark Warning
This device is compliant with Class A of CISPR 32. In a residential environment
this equipment may cause radio interference.
WEEE Warning
To avoid the potential eects on the environment and human health
as a result of the presence of hazardous substances in electrical and
electronic equipment, end users of electrical and electronic
equipment should understand the meaning of the crossed-out
wheeled bin symbol. Do not dispose of WEEE as unsorted municipal waste and
have to collect such WEEE separately.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15

Planet IPOE-470 Instrukcja obsługi

Kategoria
Przełączniki sieciowe
Typ
Instrukcja obsługi

w innych językach