Lyson W7058P Instrukcja obsługi

Typ
Instrukcja obsługi
MANUAL
Wax sterilizer
Przedsiębiorstwo Pszczelarskie Tomasz Łysoń
Spółka z o.o. Spółka Komandytowa
34-125 Sułkowice, ul. Racławicka 162, Polska
www.lyson.com.pl, email: [email protected]
tel.33/875-99-40 , 33/870-64-02Siedziba Firmy Klecza Dolna 148 ,34-124 Klecza Górna
The following manual encompasses the device bearing the following code:
W7058P
Manual
1. General safety operational principles for the device
1.1. Operational principles
1.2. Electrical safety
1.3. Operational safety
2. Device characteristics
2.1. Device description
2.2. Heater description
2.3. Technical parameters of the device
3. Device storage
4. Maintenance and cleaning
5. Recycling
6. Guarantee
1. GENERAL SAFETY OPERATING
PRINCIPLES FOR THE DEVICE
Prior to device usage initiation, refer to the
following manual and act according the guidelines
contained therein. The manufacturer shall not be
held accountable for any damages caused by
improper usage of the device or its improper
handling
1.1. Operating principles
1. The sterilizer is intended to melt the wax.
2. Prior to the first use, the sterilizer must be washed
and placed in its place of operation.
1.2. Electrical safety
1. Power supply electric installation must be
equipped with RCD with nominal tripping current In
below 30 mA. Functioning of overcurrent circuit
breaker must be checked periodically.
2. Check the nominal voltage of the sterilizer and the
power source for compliance.
3. If the power supply cable gets damaged and must
be replaced, it shall be performed by a guarantor or a
specialist service centre or a qualified person in order
to avoid any dangers. Never use the sterilizer if the
power supply cable or a connecting cable is
damaged!
4. Prior to connecting the device to the mains,
make sure that the potentiometer knob on the
heater (G) is in “0” position.
5. While connecting to the mains, be careful.
Hands must be dry! The floor on which the
sterilizer is placed must be dry too!
6. Do not displace the sterilizer while in operation.
7. Protect the controller against humidity (also
during the storage).
8. It is forbidden to pull the power supply cable. The
power supply cable must be kept away from any heat
sources, sharp edges and its proper state must be
secured.
.
1.3. Operational safety
1.The following equipment is not intended to be used
by persons with limited physical, sensory or mental
capabilities (including children) or persons
inexperienced or unfamiliar with that type of
equipment unless the usage occurs under
supervision or in line with the equipment operating
manual provided by safety supervising persons.
Make sure that children do not play with the device.
2. In case when the sterilizer gests damaged , in
order to avoid any dangers, the repair may be
performer by a specialist service centre or a qualified
person only.
3. Do not perform any maintenance works nor fault
removals while the device is in operations or is
connected to the mains!
4. The device must not be operated nor stored with
the temperatures below 0º C. The sterilizer must not
be switched on when the ambient temperature drops
below 5º
5. Prior to the device activation, when it has been
brought from a room with lower temperature to a
room with higher temperature, wait until the device
has reached the ambient temperature .
2. Device characteristics
The sterilizer is made of stainless and acid-resistant
steel plate . It is intended to perform the wax melting
process in the proper temperature in order to
remove the spores of American foulbrood.
2.1 Device description fig.1
A B D C
fig.2
E F
fig.3
G
Sterilizer description:
A-3/4” drain valve for wax
B-2drain valve for water
C-½” drain valve for oil or glycol
D-stainless and acid-resistant steel tank 200L.
E-stainless acid-resistant steel tank lid
F-heating mantle vent
G-heater with the temperature regulator
2.2 Description of the heater with the
temperature regulator:
- The heater G (fig.3) with the power of 6 kW
and the power supply of 400V is equipped
with a temperature regulator, regulation range
50-190 °C . Temperature is regulated
manually by means of a potentiometer.
2.3 Technical parameters of the device
-power supply 400V
-heater power 6000W
-temperature range 50-190 °C
-capacity 200 L.
-capacity of a heating mantle 100 L.
-tank weight (without oil or glycol)75 kg.
-external dimensions: diameter x height:
960x860xH-1100mm.
Ø zew. zbiornika - 705 mm
Ø wew. zbiornika - 583 mm
NOTE
The heating jacket of the tank must be
filled with heating oil with boiling point of at
least 230°C.
To the height of the vent at the utmost (F).
3. Device storage
After work termination, the device must be washed
and dried carefully. Store in dry rooms with the
temperature over 0 degrees C.
Prior to every season, an additional inspection
must be performed for technical issues and in case
any fault has been detected, a service point must
be contacted
4. Maintenance and cleaning
Prior to the maintenance, the plug must
be taken out from the mains
While washing, take special precautions not to
dampen the controller (it may be covered with a
water-resistant material).
After washing, dry the device carefully.
Prior to every season, an additional inspection must
be performed for technical issues and in case any
fault has been detected, a service point must be
contacted.
5. Recycling
Worn-out product must be removed as waste only
within selective waste collection organised by the
Network of Communal Electric and Electronic Waste
Collecting Points. A customer is entitled to return the
used equipment to the electrical equipment distributor
network, at least free of charge and directly, if the
device to be returned is of proper type and serves the
same purpose as the newly purchased device
6. Guarantee
Product purchased from “Łysoń’ company are
encompassed by the manufacturer’s guarantee.
The guarantee duration equals 2 years.
A receipt or a VAT invoice is issued for each product
purchased.
Detailed guarantee terms and conditions, see
www.lyson.com.pl
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Lyson W7058P Instrukcja obsługi

Typ
Instrukcja obsługi

w innych językach