Sophos SG 105(w) Operating Instructions Manual

Typ
Operating Instructions Manual
Operating Instructions
SG 105(w)/115(w)/125(w)/135(w) Rev. 3
1SG 105(w)/115(w)/125(w)/135(w) Rev. 3
Operating Instructions
Foreword
We are pleased to welcome you as a new customer of our Sophos SG appliances.
To install and configure the hardware appliance you can use the following
documents:
Ì Hardware Quick Start Guide: Connection to the
system peripherals in a few steps
Ì Operating Instructions: Notes on the security and
commissioning of the hardware appliance
Ì Administration Guide: Installing and configuring the software appliance
The Hardware Quick Start Guide and the Safety Instructions are also delivered
in printed form together with the hardware appliance. The instructions must be
read carefully prior to using the hardware and should be kept in a safe place.
You may download all user manuals and additional documentation from the
support webpage at: sophos.com/support
Security Symbols
The following symbol and its meaning appears in the Hardware Quick Start
Guide, Safety Instructions and in these Operating Instructions.
Caution and Important Note. If these notes are not correctly observed:
Ì This is dangerous to life and the environment
Ì The appliance may be damaged
Ì The functions of the appliance will be no longer guaranteed
Ì Sophos shall not be liable for damages arising from a
failure to comply with the Safety Instructions
Designed Use
The hardware appliances are developed for use in networks.
The SG 105(w)/115(w)/125(w)/135(w) models may be operated as a standalone
appliance. The hardware appliance can be used in commercial, industrial and
residential environments.
The SG 105(w)/115(w)/125(w)/135(w) models belong to the appliance group B.
The hardware appliance must be installed pursuant to the current installation
notes. Otherwise failure-free and safe operation cannot be guaranteed. The EU
declaration of conformity is available at the following address:
Sophos Technology GmbH
Amalienbadstr. 41/Bau 52
76227 Karlsruhe
Germany
2SG 105(w)/115(w)/125(w)/135(w) Rev. 3
Operating Instructions
CE Labeling, FCC and Approvals
The SG 105(w)/115(w)/125(w)/135(w) appliances comply with CB, CE, FCC
Class B, ISED, VCCI, RCM, UL, CCC, and BIS.
Important Note: For computer systems to remain CE and FCC compliant, only CE
and FCC compliant parts may be used. Maintaining CE and FCC compliance also
requires proper cable and cabling techniques.
Operating Elements and Connections
SG 105(w)/115(w)
*
(Rev. 3)
Status LEDs
(w-model has additional Wi-Fi LED)
1 x COM
(RJ45)
2 x external antenna
(SG 105w and SG 115w only)
2 x
USB 2.0
1 x Micro
USB
4 x GbE
copper port
1 x GbE SFP
(shared)
1 x
HDMI
Power Supply
Connector for optional 2nd
redundant power supply
SG 125(w)/135(w)
*
(Rev. 3)
Status LEDs
(w-model has additional Wi-Fi LED)
1 x COM
(RJ45)
3 x external antenna
(SG 125w and
SG 135w only)
2 x
USB 2.0
8 x GbE
copper port
Power
Supply
Optional 2nd redundant
power supply
1 x Micro
USB
1 x
HDMI
Expansion bay
(shown with optional
module incl. 2 antennas)
1 x GbE
SFP
* The displayed front images are of the SG 115 and 135 device. The displayed back images are of the SG 115w device
and the SG 135w. Devices may vary slightly.
3SG 105(w)/115(w)/125(w)/135(w) Rev. 3
Operating Instructions
LED Status
LEDs on Front
Storage
Blue
Flashing SSD drive is being accessed
Status Green Constantly Normal operation
Flashing Device is booting up or shutting down
Red Constantly SSD or boot failure
Flashing General error (please contat support)
Wifi Green On Wifi is active
Off Wifi is inactive
Power 1 Green Constantly Power adapter 1 in normal operation
Red Constantly Power adapter 1 failed or disconnected
Power 2 Green Constantly Power adapter 2 in normal operation
Red Constantly Power adapter 2 failed or disconnected
LEDs on each RJ45 Ethernet connector
ACT/LNK
(Left LED)
Green Constantly 1. The Ethernet port is receiving power.
2. Good connection between the Ethernet port and hub.
Flashing The adapter is sending or receiving network data. The
frequency of the flashes varies with the amount of traffic.
Off 1. The adapter and switch are not receiving power.
2. No connection between both ends of network.
3. Network drivers have not been loaded
or do not function correctly.
Speed
(Right LED)
Amber On The Ethernet port is operating at 1,000 Mbps.
Green On The Ethernet port is operating at 100 Mbps.
Off The Ethernet port is operating at 10 Mbps.
LEDs on SFP connector
ACT/LNK
(Left LED)
Green Constantly 1. The SFP connector is receiving power.
2. Good connection between the SFP connector and hub.
Flashing The adapter is sending or receiving network data.
The frequency of the flashes varies with the amount of traffic.
Off 1. The adapter and switch are not receiving power.
2. No connection between both ends of network.
3. Network drivers have not been loaded
or do not function correctly.
Speed (Right
LED)
Amber On The Ethernet port is operating at 1,000 Mbps
Putting into Operation
Caution: Risk of explosion if battery is replaced by an incorrect type. Dispose of
used batteries according to the instructions.
Scope of Supply
The supplied parts are indicated in the Hardware Quick Start Guide.
Mounting Instructions
The SG 105(w)/115(w)/125(w)/135(w) appliances can be placed on a stable
horizontal surface or can be mounted to a rack or you can hang it on the wall by
using the optionally available rackmount kit.
4SG 105(w)/115(w)/125(w)/135(w) Rev. 3
Operating Instructions
Warnings and Precautions
The appliance can be operated safely if you observe the following notes and the
notes on the appliance itself.
Rack Precautions
Ì Ensure that the leveling jacks on the bottom of the rack are fully
extended to the floor with the full weight of the rack resting on them.
Ì In single rack installation, stabilizers should be attached to the rack.
Ì In multiple rack installations, the racks should be coupled together.
Ì Always make sure the rack is stable before
extending a component from the rack.
Ì You should extend only one component at a time—extending two or
more simultaneously may cause the rack to become unstable.
General Server Precautions
Ì Review the electrical and general safety precautions that came
with the components you are adding to your appliance.
Ì Determine the placement of each component in
the rack before you install the rails.
Ì Install the heaviest server components on the
bottom of the rack first, and then work up.
Ì Allow the hot plug hard drives and power supply
modules to cool before touching them.
Ì Always keep the rack‘s front door, all panels and server components
closed when not servicing to maintain proper cooling.
Rack Mounting Considerations
Ì Ambient operating temperature: If installed in a closed or multi-unit rack
assembly, the ambient operating temperature of the rack environment
may be greater than the ambient temperature of the room. Therefore,
you should install the equipment in an environment compatible
with the manufacturer’s maximum rated ambient temperature.
Ì Reduced airflow: Equipment should be mounted into
a rack with sufficient airflow to allow cooling.
Ì Mechanical loading: Equipment should be mounted into a rack so that a
hazardous condition does not arise due to uneven mechanical loading.
Ì Circuit overloading: Consideration should be given to the connection
of the equipment to the power supply circuitry and the effect that any
possible overloading of circuits might have on overcurrent protection
and power supply wiring. Appropriate consideration of equipment
nameplate ratings should be used when addressing this concern.
Ì Reliable ground: Reliable grounding must be maintained at all times.
To ensure this, the rack itself should be grounded. Particular attention
should be given to power supply connections other than the direct
connections to the branch circuit (i.e., the use of power strips, etc.).
5SG 105(w)/115(w)/125(w)/135(w) Rev. 3
Operating Instructions
Connection and Configuration
How to connect the appliance is described in the Hardware Quick Start Guide. For
configuration you can follow the initial setup wizard described in the WebAdmin
Quick Start Guide or cancel it and perform a manual setup (see the Sophos SG
Firewall Administrator Guide).
SFP Port
The XG1xx rev.3 models provide a SFP port allowing you to either insert a SFP
Mini-GBIC (transceiver) to connect to a 1 GbE fiber or copper cable or to insert a
VDSL2 SFP modem to directly connect to a VDSL line (via a RJ11 cable).
These modules are not delivered with the appliance but available through your
Sophos partner.
Please note that there are different Mini-GBIC module types. The required type is
determined by the existing network. The following SFP GBIC module types may
be used:
SFP:
1000 Base-T
IEEE 802.3 - 1 Gbit/s via Ethernet cable. An Ethernet cable category 5 covers a
maximum distance about 100 meters.
1000 Base-SX
IEEE 802.3 - 1 Gbit/s via fiberglass. Multi-mode fiberglass cables (MMF) cover a
distance of 200 m to 550 m.
1000 Base-LX
IEEE 802.3 - 1 Gbit/s via fiberglass. Here, exclusively singlemode-fiber glass is
used. This transmission option covers approximately 10 km.
Caution: The SFP GBIC fiber modules use lasers to transmit signals over fiber
optic cable. The lasers are compliant with the requirements of a Class 1 Laser
equipment and are inherently eye-safe in normal operation. However, you
should never look directly at a transmit port when it is powered on. Always install
appropriate and UL approved Laser Class I Transceivers, rated 3.3Vdc, max. 1W,
in the fiber ports before using the fiber ports.
Please note: on SG 105/115 models the SFP port is shared with RJ45 Ethernet
Port 4 and takes precendence over the RJ45 port in case you connect cables to
both ports at the same time.
Installing a SFP module:
Please read the operation manual to the SFP module. Carefully insert the SFP
module into the port until it engages. The interface is immediately ready for use.
Removing a SFP module:
1. Remove the fiberglass cable (if needed) from the
module which you wish to remove.
2. Remove the module carefully from the port.
Depending on when you purchased your SFP module, it may have any of three
different release mechanisms: a plastic tab on the bottom of the miniGBIC, a wire
bail, or a plastic collar around the mini-GBIC. Please read the operation manual to
the SFP module
6SG 105(w)/115(w)/125(w)/135(w) Rev. 3
Operating Instructions
Expansion Modules
The SG 125(w)/135(w) support an additional expansion module allowing you to
insert an optional 3G/4G or Wireless module (on SG 135w only). These modules
are not delivered with the appliance but available through your Sophos partner.
Please note that there are different 3G/4G modules available depending on the
region you want to operate it in Americas/EMEA and APAC.
Please see table below for further details.
Target Region Americas/EMEA APAC
4G LTE
Category Cat-6 Cat-6
Frequency Bands B1, B2, B3, B4, B5, B7,
B12, B13, B20, B25,
B26, B29, B30, B41
B1, B3, B5, B7, B8, B18, B19,
B21, B28, B38, B39, B40, B41
3G
1. Technology supported WCDMA WCDMA
Frequency Bands B1, B2, B3, B4, B5, B8 B1, B5, B6, B8, B9, B19
2. Technology supported TD-SCDMA
Frequency Bands B39
DATA SPEED
Peak Downlaod Rate 300 Mbps 300 Mbps
Peak Upload Rate 50 Mbps 50 Mbps
LOCATION SERVICES
Satellite Systems GPS, Galileo, Glonass, Beidou GPS, Galileo, Glonass, Beidou
For installing the module please read the mounting instructions which are
shipped with each module.
Serial Console
You can connect a serial console to either of the COM ports of the Sophos SG
hardware appliances. You can use, for instance, the Hyperterminal terminal
program which is included with most versions of Microsoft Windows to log on to
the appliance console. Use an RJ45 to DB9 adapter cable or the provided USB
cable to connect the console to your hardware appliance.
The required connection settings are:
Ì Bits per second: 38,400
Ì Data bits: 8
Ì Parity: N (none)
Ì Stop bits: 1
Access via the serial console is activated by default on ttyS1. The connections of
the appliances and the respective functionality are listed in chapter “Operating
Elements and Connections.
Operating Instructions
United Kingdom and Worldwide Sales
Tel: +44 (0)8447 671131
North American Sales
Toll Free: 1-866-866-2802
Australia and New Zealand Sales
Tel: +61 2 9409 9100
Asia Sales
Tel: +65 62244168
© Copyright 2018. Sophos Ltd. All rights reserved.
Registered in England and Wales No. 2096520, The Pentagon, Abingdon Science Park, Abingdon, OX14 3YP, UK
Sophos is the registered trademark of Sophos Ltd. All other product and company names mentioned are
trademarks or registered trademarks of their respective owners.
18-01-26 OINA (DD-2919)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Sophos SG 105(w) Operating Instructions Manual

Typ
Operating Instructions Manual

w innych językach