Novus NVIP-2Q-6101/PIR/W Instrukcja obsługi

Kategoria
Kamery ochrony
Typ
Instrukcja obsługi
Quick sta rt gu i de
NVIP-2Q-6101/PIR/W
NVIP-2Q-6101/PIR/W Quick start guide ver. 1.1.1
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
2
IMPORTANT SAFEGUARDS AND WARNINGS
THE PRODUCT MEETS THE REQUIREMENTS CONTAINED IN THE FOLLOWING DIRECTIVES:
Information
The device, as a part of professional CCTV system used for surveillance and control, is not designed
for self installation in households by individuals without technical knowledge.
Excluding of responsibility in case of damaging data on a disk or other devices:
The manufacturer does not bear any responsibility in case of damaging or losing data on a disk or other
devices during device operation.
WARNING!
PRIOR TO UNDERTAKING ANY ACTION THAT IS NOT DESCRIBED FOR THE GIVEN
PRODUCT IN USERS MANUAL AND OTHER DOCUMENTS DELIVERED WITH THE
PRODUCT, OR IF IT DOES NOT ARISE FROM THE USUAL APPLICATION OF THE
PRODUCT, MANUFACTURER MUST BE CONTACTED UNDER THE RIGOR OF EXCLUDING
THE MANUFACTURERS RESPONSIBILITY FOR THE RESULTS OF SUCH AN ACTION.
DIRECTIVE 2014/30/EU OF THE EUROPEAN PARLIAMENT
AND OF THE COUNCIL of 26 February 2014 on the harmonisation of the
laws of the Member States relating to electromagnetic compatibility
(OJ L 96, 29.3.2014, p. 79106, with changes)
DIRECTIVE 2012/19/EU OF THE EUROPEAN PARLIAMENT
AND OF THE COUNCIL of 4 July 2012 on waste electrical and electronic
equipment (WEEE) (OJ L 197, 24.7.2012, p. 3871,with changes)
DIRECTIVE 2011/65/EU OF THE EUROPEAN PARLIAMENT
AND OF THE COUNCIL of 8 June 2011 on the restriction of the use
of certain hazardous substances in electrical and electronic equipment
(OJ L 174, 1.7.2011, p. 88110, with changes)
NVIP-2Q-6101/PIR/W Quick start guide ver. 1.1.1
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
3
IMPORTANT SAFEGUARDS AND WARNINGS
WARNING!
THE KNOWLEDGE OF THIS MANUAL IS AN INDESPENSIBLE CONDITION OF A PROPER DEVICE
OPERATION. YOU ARE KINDLY REQUSTED TO FAMILIRIZE YOURSELF WITH THE MANUAL
PRIOR TO INSTALLATION AND FURTHER DEVICE OPERATION.
WARNING!
USER IS NOT ALLOWED TO DISASSEMBLE THE CASING AS THERE ARE NO USER-
SERVICEABLE PARTS INSIDE THIS UNIT. ONLY AUTHORIZED SERVICE PERSONNEL MAY OPEN
THE UNIT.
INSTALLATION AND SERVICING SHOULD ONLY BE DONE BY QUALIFIED SERVICE PERSONNEL
AND SHOULD CONFORM TO ALL LOCAL REGULATIONS.
IMPORTANT SAFEGUARDS AND WARNINGS
1. Prior to undertaking any action please consult the following manual and read all the safety and operating
instructions before starting the device.
2. Please keep this manual for the lifespan of the device in case referring to the contents of this manual is
necessary;
3. All the safety precautions referred to in this manual should be strictly followed, as they have a direct
influence on users safety and durability and reliability of the device;
4. All actions conducted by the servicemen and users must be accomplished in accordance with the users
manual;
5. The device should be disconnected from power sources during maintenance procedures;
6. Usage of additional devices and components neither provided nor recommended by the producer is forbidden;
7. Mounting the device in places where proper ventilation cannot be provided (e. g. closed lockers etc.) is not
recommended since it may lead to heat build-up and damaging the device itself as a consequence;
8. Mounting the camera on unstable surface or using not recommended mounts is forbidden. Improperly
mounted camera may cause a fatal accident or may be seriously damaged itself. The camera must be mounted
by qualified personnel with proper authorization, in accordance with this users manual.
9. Device should be supplied only from a power sources whose parameters are in accordance with those
specified by the producer in the camera technical datasheet. Therefore, it is forbidden to supply the camera
from a power sources with unknown parameters, unstable or not meeting producers requirements;
10. Signal cables (conducting TV or / and telemetric signal) should be placed in a way excluding the possibility
of damaging them by accident. Special attention must be paid to cables getting from the camera and
connecting the power supply;
11. To avoid equipment damage, whole TV circuit should be equipped with properly made discharge-, overload-
and lightning protection devices. Usage of separating transformers is advised;
12. Electric installation supplying the device should be designed to meet the specifications given by the producer
in such a way that overloading is impossible;
13. User cannot repair or upgrade the equipment himself. All maintenance actions and repairs should be
conducted only by qualified service personnel;
14. Unplug the camera from the power source immediately and contact the proper maintenance department
when the following occurs:
Damages to the power cord or to the plug itself;
Liquids getting inside the device or exposure to strong mechanical shock;
Device behaves in a way not described in the manual and all adjustments approved by the
manufacturer and possible to apply by user himself, seem not to have any effect;
Camera or its casing is damaged;
Atypical behaviour of the camera components can be seen (heard).
15. In necessity of repairs attention to using only original replacement parts (with their parameters in accordance
with those specified by the producer) should be paid. Non-licensed service and non-genuine replacement
parts may cause fire or electric shock.
NVIP-2Q-6101/PIR/W Quick start guide ver. 1.1.1
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
4
TABLE OF CONTENTS
TABLE OF CONTENTS .................................................................................................... 4
1. FOREWORD INFORMATION ................................................................................... ..5
1.1. General characteristics......................................................................................... 5
1.2. Technical specification .................................................................................... ...6
1.3. Camera dimension ........................................................................................... ...8
1.4. Package contents .............................................................................................. ...8
2. START-UP AND INITIAL CAMERA CONFIGURATION ...................................... 9
2.1. Description of camera components and connectors ............................................ 9
2.2. Power supply connection ..................................................................................... 9
2.3. Connection of alarm input/output ...................................................................... 10
2.4. Connecting the LAN network cable .................................................................. 11
2.5. Camera mounting .............................................................................................. 11
2.6. Starting the camera ............................................................................................ 12
2.6.1. Starting with connecting the camera to a wired LAN network ................ 12
2.6.1.1. Configuring network settings using a DHCP server ..................... 13
2.6.1.2. Manual configuration of network settings ..................................... 13
2.6.2. Starting with connecting the camera to a WiFi network .......................... 13
2.7. Security recommendations for network architecture and configuration ........... 14
3. CONNECTING FROM A PC WITH A WEB BROWSER ....................................... 15
3.1. First connection to the camera ........................................................................... 15
3.2. Login screen ....................................................................................................... 16
3.3. Remote view window ......................................................................................... 17
4. CONNECTION FROM A DEVICE EQUIPPED WITH ANDROID SYSTEM ..... 19
5. RESTORING FACTORY SETTINGS ........................................................................ 19
5.1. Software factory reset ........................................................................................ 19
5.2. Hardware factory reset ...................................................................................... 19
NVIP-2Q-6101/PIR/W Quick start guide ver. 1.1.1
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
5
1. FOREWORD INFORMATION
1.1. General Characteristics
Sensor resolution: 2 megapixels
Mechanical IR cut filter, IR operation capability
Min. Illumination from 0 lx with IR LED on
Wide Dynamic Range (WDR) for enhanced image quality in diverse light conditions
Digital Noise Reduction (DNR)
Lens with remote focal and focus control, f=2.8mm/F=1.85
Built-in LED illuminator: 1 pc LED
Compression of video stream: H.264/H265/MJPEG
Max video processing resolution: 1920 x 1080
Three independently configurable streams
Stream parameters: compression, resolution, speed and quality defined individually for each video
stream
RTP/RTSP protocol support for video transmission
Two-way audio transmission
Compression of audio stream: G.711
Wireless WiFi and wired LAN connections
Alarm input and output
Hardware motion detection
Hardware sabotage detection (lens shade)
Built-in webserver: camera configuration through the website
Wide range of responses to alarm events: e-mail with attachment, saving file on FTP server,
activation of alarm output
Four privacy zones
Eight definable Region of Interest
Power supply: 12VDC, PoE (Power over Ethernet 802.3af)
Information
The manufacturer reserves the right to printing errors and technical specifications changes
without prior notice.
FOREWORD INFORMATION
NVIP-2Q-6101/PIR/W Quick start guide ver. 1.1.1
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
6
TECHNICAL SPECIFICATION
1.2. Technical specification
IMAGE
Image Sensor 2 MPX CMOS sensor 1/2.7” SmartSens
Number of Eecve Pixels 1936 (H) x 1096 (V)
Min. Illuminaon
0.007 lx/F1.2 - color mode,
0 lx (IR on) - B/W mode
Electronic Shuer auto: 1 s ~ 1/100000 s
Digital Slow Shuer (DSS) up to 1 s
Digital Noise Reducon (DNR) 3D
Defog Funcon (F-DNR) yes
Back Light Compensaon (BLC) yes
Reducon of image icker (Anicker) yes
LENS
Lens Type standard, f=2.8 mm/F1.85
DAY/NIGHT
Switching Type mechanical IR cut lter
Switching Mode auto, manual, me
Switching Level Adjustment yes
Switching Delay 2 ~ 120 s
Visible Light Sensor yes
NETWORK
Stream Resoluon
1920 x 1080 (Full HD), 1280 x 720 (HD), 704 x 576, 480 x 240,
352 x 288 (CIF)
Frame Rate 25 fps for each resoluon
Mulstreaming Mode 3 streams
Video/Audio Compression H.264, H.265, MJPEG/G.711
Number of Simultaneous Connecons max. 4
Bandwidth 8 Mb/s in total
Network Protocols Support
HTTP, TCP/IP, IPv4/v6, UDP, HTTPS, FTP, DHCP, DDNS, NTP, RTSP,
UPnP, QoS, IEEE 802.1X, PPPoE, SMTP
ONVIF Protocol Support Prole S
Camera Conguraon
from Internet Explorer browser
languages: Polish, English, Russian, and others
Compable Soware NMS
Mobile applicaons SuperLive Plus (iPhone, Android)
WIFI
Network standard IEEE802.11b, g, n
Band 2.4GHz
Security WEP, WPA-PSK/WPA2-PSK
Transmission range up to 50 m
Antenna built-in, omnidireconal
NVIP-2Q-6101/PIR/W Quick start guide ver. 1.1.1
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
7
TECHNICAL SPECIFICATION
The declared range of the WiFi network is based on laboratory research and relates to open
spaces. It should be noted, that the materials used for the construction of houses and flats, wall
thickness and electromagnetic field conditions in the immediate surroundings may affect the
range of the network.
OTHER FUNCTIONS
Privacy Zones 4
Moon Detecon yes
PIR detector range up to 7 m
Region of interest (ROI) 3
Video Content Analysis (VCA) line cross, zone entrance
Image Processing
90˚ image rotaon, 180˚ image rotaon, mirror eect, corridor
mode, vercal ip, horizontal ip
Prealarm/Postalarm up to 6 s/up to 120 s
System Reacon to Alarm Events
e-mail with aachment, saving le on FTP server, saving le on SD
card, alarm output acvaon
IR LED
LED Number 1
Range 10 m
Angle 120°
Smart IR yes (soware support)
INTERFACES
Audio Input/Output built-in microphone/speaker
Alarm Input/Output 1 (NO/NC)/1 relay type
Network Interface
1 x Ethernet - RJ-45 interface, 10/100 Mbit/s
Wireless (WiFi)
Memory Card Slot microSD - capacity up to 128GB
INSTALLATION PARAMETERS
Dimensions (mm)
63 (W) x 109 (H) x 30 (L)
with bracket: 72 (W) x 130 (H) x 72 (L)
Weight 0.2 kg
Enclosure plasc, black and white, wall mount/base in-set included
Power Supply PoE, 12 VDC
Surge protecon TVS 4000 V
Power Consumpon 2 W,3 W (IR on)
Operang Temperature -10°C ~ 45°C
Humidity max. 95%, relave (non-condensing)
NVIP-2Q-6101/PIR/W Quick start guide ver. 1.1.1
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
8
START-UP AND INITIAL CONFIGURATION
1.3. Camera dimensions
1.4. Package contents
After you open the package make sure that the following elements are inside:
IP camera
Accessories bag
Quick start guide
Before starting the device familiarize yourself with the description and the role of particular
inputs, outputs and adjusting elements that the device is equipped with. If you have any
problems understanding the manual, please contact the AAT. Self-assembly and commissioning
of the camera is possible, provided that the person has basic knowledge of computer networks
and the use of appropriate tools.
Caution:
If the device was brought from a location with lower temperature, please wait until it reaches the
temperature of location it is currently in. Turning the device on immediately after bringing it
from a location with lower ambient temperature is forbidden, as the condensing water vapour
may cause short-circuits and damage the device as a result.
NVIP-2Q-6101/PIR/W Quick start guide ver. 1.1.1
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
9
START-UP AND INITIAL CONFIGURATION
2. START-UP AND INITIAL CONFIGURATION
2.1. Description of camera components and connectors
2.2 Power supply connection
When powering the camera from an external 12VDC power supply, make sure that it has the correct
parameters and the power supply plug - the correct polarity. The use of a power source with
inappropriate parameters may result in incorrect operation or damage of the camera.
1 Lens 9 LAN socket
2 IR LED (infrared illuminator) 10 Loudspeaker
3 Microphone 11 Block of alarm input/output connectors
4 PIR detector 12 12VDC power socket
5 Power indicator 13 Reset/WPS button
6
Network connection indicator:
flashes when connecting via RJ45 cable
14 Memory card slot
7
Alarm input alarm signaling.
Signaling connection to a WiFi network
using WPS
15 Camera position adjustment
8 Light sensor 16 Base
Center pin: +12V
GND
NVIP-2Q-6101/PIR/W Quick start guide ver. 1.1.1
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
10
START-UP AND INITIAL CONFIGURATION
The camera can also be powered via an RJ45 network connector, using PoE (IEEE 802.3af)
technology. Please, use a network switch or an IEEE 802.3af compliant PoE power supply to power
the camera through the PoE.
2.3. Connection of alarm input/output
The camera has one alarm input and output. The alarm input is used to connect a device such as a
motion detector, button, reed switch or photocell. Violation of the input will trigger the alarm and
activate the previously programmed action.
The alarm output enables connection of an external siren and implementation of automatic control
functions, such as switching on lighting.
Podłączenie wejścia alarmowego
Podłączenie wyjścia alarmowego
I Alarm input, configurable: NC or NO
G Ground (common terminal)
O Alarm output terminal, (12VDC/0.1A maks.)
Caution:
It is forbidden to use – as the camera power source – PoE equipment (adapters, etc.) not
compatible with IEEE 802.3af standard (items called passive PoE power supply”). Damages
that results from the usage of improper power supply source are not covered by the warranty.
trigger contact
signaling device
maximum load 0.1A
signaling device power
supply 12VDC max.
NVIP-2Q-6101/PIR/W Quick start guide ver. 1.1.1
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
11
START-UP AND INITIAL CONFIGURATION
2.4. Connecting the LAN network cable
To connect to the camera via a wired LAN, insert the LAN cable plug into the LAN socket so that the
plug latch clicks into the socket. Connect the other end of the cable to your switch / router.
2.5. Camera mounting
The camera design allows flexible selection of the place of attachment / installation. The camera can
work when placed on any flat surface or be hung using mounting holes in the foot.
To mount the camera in a hanging position, we recommend you follow the following guidelines:
Place the template where you want to install the camera. Then drill the holes according to the
template.
Insert the dowels into the holes and tighten the screws. The screws should protrude a few
millimeters above the wall surface.
Route and connect the cables to the camera.
Hang the camera by the mounting base on the screws and make sure it is securely fastened.
Then adjust the camera position.
Caution:
The camera is designed for indoor use in living quarters. Using it outdoors, or in rooms with
high humidity such as swimming pools, bathrooms, laundries, etc. may cause the camera to
malfunction or damage.
NVIP-2Q-6101/PIR/W Quick start guide ver. 1.1.1
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
12
2.6. Starting the camera
2.6.1 Starting with connecting the camera to a wired LAN network
To start the camera, connect the Ethernet cable to the camera's network socket, and the other end to the
switch or router. If your switch or router is not a PoE device, you should also connect a 12VDC power
supply to the camera. The following schemes may help:
Wired connection using a PoE switch or router:
Wired connection using a switch or router without PoE and 12VDC power supply:
After making connections and starting the camera (which takes about 2 minutes) it is possible to
connect to the camera. Use Internet Explorer to connect to the camera.
After entering the default address in the browser's address bar, wait for the login page to appear. If the
page did not appear, and the browser displayed a connection error message "This page cannot be
displayed", check the compatibility of the IP addresses of the camera and the network in which it will
work and make the appropriate configuration.
To configure the network settings you will need the "NMS IP Tool" application, which can be
downloaded from the product page at www.novuscctv.com.
START-UP AND INITIAL CONFIGURATION
PC
Camera
Data transmission
Switch or router with PoE
Power supply and data
transmission
Camera
PC
Data transmission
Switch or router without PoE
Data transmission
Power supply
NVIP-2Q-6101/PIR/W Quick start guide ver. 1.1.1
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
13
START-UP AND INITIAL CONFIGURATION
Połączenie wykorzystujące zewnętrzne zasilanie kamery i kabel ethernetowy
2.5. Konfiguracja parametrów przy użyciu przeglądarki internetowej
Domyślne ustawienia sieciowe dla kamery to:
1. Adres IP = 192.168.1.200
2. Maska sieci - 255.255.255.0
3. Brama - 192.168.1.1
4. Nazwa użytkownika - root
5. Hasło - pass
Znając adres IP kamery należy ustawić adres IP komputera w taki sposób aby oba urządzenia
pracowały w jednej podsieci (dla adresu IP kamery 192.168.1.200 jako adres IP komputera PC
możemy ustawić adres z zakresu 192.168.1.0 - 192.168.1.254, np.: 192.168.1.60). Niedopuszczalne jest
ustawianie adresu komputera takiego samego jak adres kamery.
Wykorzystując połączenie przez przeglądarkę internetową Internet Explorer lub oprogramowanie NMS
należy ustawić docelową konfigurację siecio (adres IP, maskę sieci, bramę, serwery DNS)
lub włączyć tryb pracy DHCP pozwalający na pobranie adresu IP z serwera DHCP (wymagany jest
wówczas działający serwer DHCP). W przypadku korzystania z serwera DHCP należy upewnić się
co do długości okresu dzierżawy adresu IP, jego powiązania z adresem MAC kamery IP w celu
uniknięcia zmiany lub utraty adresu IP w czasie pracy urządzenia lub chwilowej awarii sieci / serwera
DHCP. Należy pamiętać że po zmianie adresu IP kamera zostanie zresetowana i trzeba wpisać nowy
adres w przeglądarce internetowej. Po konfiguracji ustawień sieciowych pozwalających na
bezkonfliktową pracę urządzenia, kamerę IP możemy podłączyć do sieci docelowej.
2.6.1.1 Configuring network settings using a DHCP server
After launching the application and searching for the camera, check the box next to its address. Enter
the login details in the network settings change panel, select "DHCP" in the "IP mode" window (leave
the other fields unfilled) and press the "IP Change" button. After a while, the camera will start with the
new IP address given by the DHCP server built into the router/switch.
2.6.1.2 Manual configuration of network settings
We check the IP address in the computer's network settings. Then select a new IP address for the
camera, check if it is not busy (eg using the "ping" command at the command prompt) and change the
camera address in the application. After a while, the camera will start with the new IP address assigned.
After changing the camera's IP address, you should be able to connect to it using Internet Explorer.
Further configuration of the camera is carried out via its web panel (see chapter 3 on page 15).
2.6.2 Starting with connecting the camera to a WiFi network
To start the camera, connect a 12VDC power supply.
After the camera starts up (which takes up to 2 minutes), press the WPS button on the router. Then,
within two minutes, press the RESET / WPS button on the camera. The process of connecting the
camera to the WiFi network begins, which is signaled by continuous lighting of the "Alarm" LED.
After successful connection the diode goes out. Connection error is indicated by flashing of this LED.
To check which IP address has been assigned to the camera, start the "NMS IP Tool" application, or
connect to the router configuration page and check the camera address in the list of DHCP clients.
Configuring the camera's IP address using a DHCP server is quick and convenient. However, at
a later stage of camera use it is recommended to set a static IP address in it. This will prevent
connection loss if the DHCP server changes the camera address.
The default camera network settings are:
IP address: 192.168.1.200, network mask: 255.255.255.0, login details: login - root, password -
pass
Caution:
Do not connect the RJ45 network cable. Connecting a network cable disables the WiFi network.
Caution:
Detailed information about network settings, WPS button operation and assigned address
verification should be available in the router's user manual.
NVIP-2Q-6101/PIR/W Quick start guide ver. 1.1.1
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
14
START-UP AND INITIAL CONFIGURATION
2.7 Security recommendations for network architecture and configuration
WARNING!
Below are shown security recommendations for network architecture and configuration of
CCTV systems that are connected to the Internet to reduce the risk of unauthorized interference
with the system by a third party.
1. Absolutely change the default passwords and user names (if the device gives this possibility) of
all applied network devices (recorders, cameras, routers, network switches, etc.) to the
severely complexity password. Use lowercase and uppercase letters, numbers, and special characters
if there is such possibility.
2. Depending on the available functionality in the order to restrict access to the used network devices at
the administrator account level, it is recommended to configure the users accounts accordingly.
3. Do not use DMZ function (Demilitarized zone) in your router. Using that function you open the
access to recorder system from the Internet on all ports, which gives possibility for an unauthorized
interference with the system.
Instead of DMZ use port forwarding redirect only the ports which are necessary for the performance
of the connection (detailed information about ports of communication in different models of recorders,
cameras, etc. can be found in the operating instructions).
4. Use routers with firewall function and make sure it is enabled and properly configured.
5. It is recommended to change the default network communication port numbers of used devices
if there is such possibility.
6. If used network devices has a UPnP feature and it is not used, turn it off.
7. If used network devices has a P2P feature and it is not used, turn it off.
8. If used network devices support HTTPS protocol for connection, it is recommended to use it.
9. If used network devices support IP filtering for authorized connections function, it is recommended
to use it.
NVIP-2Q-6101/PIR/W Quick start guide ver. 1.1.1
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
15
3. CONNECTING FROM A PC WITH A WEB BROWSER
3.1. First connection to the camera
After connecting and configuring the camera, you can connect to it. Enter the camera's IP address in the
address bar of Internet Explorer. After the connection is established, a message will be displayed
informing you that there is no ActiveX add-on required for proper camera operation.
To download it, click on the "Here" link. The "NetIPCamera.exe" download window will be displayed.
Then click the "Run" button.
When the add-on installer window appears, click "Install" button and install the add-on, following the
information displayed by the installer.
START-UP AND INITIAL CONFIGURATION
The installation of the add-on is one-off, it takes place during the first connection. However, on
subsequent connections, especially after changing the IP address, the browser may display a
security alert:
NVIP-2Q-6101/PIR/W Quick start guide ver. 1.1.1
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
16
WWW INTERFACE - WORKING WITH A CAMERA
3.2. Login screen
After connecting to the camera, the login screen will be displayed. Enter the login and password in
the login fields. You can also change the language of the camera interface.
The Remember meoption allows you to login to the camera without entering a password. For
security reasons, using this option is not recommended.
After logging in, a password change window will appear.
For security reasons, it is recommended to change the default password to a highly complicated one
in this step. If you do not intend to change the password at this time, after pressing "OK" the user
will be taken to the remote preview window. The "Cancel" button interrupts the process of logging
into the camera.
NVIP-2Q-6101/PIR/W Quick start guide ver. 1.1.1
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
17
WWW INTERFACE - WORKING WITH A CAMERA
3.3. Remote view window
1. Stream selection buttons for display in the remote preview window
2. Button for selecting the stream buffering level. Available options: Real-time (smallest buffer),
Balanced (default option) and Fluent (maximum buffer).
3. Preview window. Double-clicking the left mouse button on the preview window enables and
disables the display of the image on the full screen.
4. Buttons for selecting the operating mode and configure the camera:
Live - enables preview live stream
Config - displays the configuration panel camera
Search - displays the playback panel of recordings from the memory card
Logout - log off the current user
1
6
7
2 3
4
5
NVIP-2Q-6101/PIR/W Quick start guide ver. 1.1.1
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
18
5. Notification Area. Icons displayed here are informing about activated alarms. Activation of a given
alarm is signaled by a cyclical color change of the corresponding icon, from black to red.
6. Buttons to set the size and aspect ratio
7. Additional features control icons
WWW INTERFACE - WORKING WITH A CAMERA
- enables/disables live view
- enables/disables the audio transmission from the computer to the camera
- enables/disables audio transmission from the camera to the computer
- alarm input actiwation
- scene change alarm
- motion detection alarm
- PIR alarm
- line crossing alarm
- intrusion alarm
- abnormal color alarm
- SD card recording icon. Black means that the camera is ready to record on the camera,
but recording is inactive. Red indicates recording is on.
- abnormal clarity alarm
- original size
- maintains the aspect ratio
- adapts to the window
- enables full screen
NVIP-2Q-6101/PIR/W Quick start guide ver. 1.1.1
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
19
4. CONNECTION FROM A DEVICE EQUIPPED WITH ANDROID SYSTEM
To connect to the camera from an Android device, you need to download from the Google store and
install the SuperLive Plus application.
5. RESTORING FACTORY SETTINGS
5.1 Software factory reset
The camera allows to reset its settings to the factory defaults. To restore the camera settings to the
default settings, go to the Backup and restoretab (Config -> Maintenance -> Backup and restore).
Then in the "Default Settings" line select the camera options and functions whose settings are not to be
changed and press the Load defaultbutton.
Resetting to factory settings is also possible with the NMS IP toolapplication. To restore the factory
settings using this application, right-click anywhere in the row with the address of the camera found
and select Restore default configuration. Then disconnect and reconnect the camera's power supply
within 30 seconds. The camera will start with the default settings.
5.2 Hardware factory reset
To reset the camera to the factory default settings, use the RESET button located on the back. Press and
hold it for about 5 seconds.
After about 30 seconds you will be able to reconnect to the camera at the default IP address.
CONNECTION FROM A DEVICE EQUIPPED WITH ANDROID SYSTEM
A description of all camera functions is included in the full user manual on the product page at
www.novuscctv.com
- zooming in image
- takes a screenshot and saves to your PC
- enables/disables the recording of video stream on a PC
- zooming out image
11.02.2020 MB, MK v1.1.1
AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
431 Pulawska St., 02-801 Warsaw, Poland
tel.: +4822 546 07 00, fax: +4822 546 07 59
www.novuscctv.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40

Novus NVIP-2Q-6101/PIR/W Instrukcja obsługi

Kategoria
Kamery ochrony
Typ
Instrukcja obsługi

w innych językach