Elkay 360A-1 Instrukcja obsługi

Typ
Instrukcja obsługi
The Activator (3 wire) is part of the Elkay
family of switches, timers and detectors which
save energy and increase convenience in
and around your home, garden or premises.
Rating at 240V ac 50Hz
Time Delay: 2 min - 2 hrs
All load types 16A
Usage
The Activator is used to provide multiple switching
at various points in the same circuit and must be
used in conjunction with ONE Elkay Illuminated
master timer in that circuit. It is used to remotely
trigger the master timer. Any combination of
Activators can be wired to any single master timer,
thus giving a variety of activation functions in a
switching circuit.
The activator unit is compatible with a single gang,
25mm deep, British standard accessory plate.
Please ensure that the top and bottom lugs are
removed, if fi tted, from metal wall boxes
prior to fi tting and that there is adequate space
for wiring.
Wiring
See appropriate wiring diagram (see diagram 1 & 2).
Fitting and Operating Instructions
1. Turn off mains supply before installation. For best
results have a live in, live out and trigger cable
cores running between the Master and Activator
identi ed. Please note the Touch and PIR
activator must have a three-core connection
to the Master but the Push Button can sacri ce
the blue locator ring at the activators if a
third core is not available. Please select the
appropriate wiring diagram as per Master and
Activator combinations (see diagram 1 & 2).
2. PIR and Touch Activators only –
Ensure the battery jumper tag
located at the back of the unit
on the right-hand corner is fi tted
across the outer 2 pins as below.
3. PIR Activator only – Initially during the setting up
process, adjust the lux-pot at the back of the unit
anti-clockwise toward the plus (+). Upon
completion, re-adjust the lux level pot to the
desired level of operation.
Securely connect the Live In, Live Out and Trigger
cables into terminals marked Lin, Lout & T
between the Master and Activator units. Turn mains
power ON and follow the appropriate Master
Timer Installation steps/ instruction.
4. Following installation set-up, test each Activator
for functionally with the Master timer delay
timing set to the minimum setting.
ACTIVATOR
SWITCH
For use with:
Elkay 2 wire and 3 wire
Illuminated Master Timers
Instruction Guide
BROOK DESIGN HARDWARE LTD
BDH
BDH
BROOK DESIGN
HARDWARE LTD
BDHBROOK DESIGN
HARDWARE LTD
BDH
BROOK DESIGN
HARDWARE LTD
BDH
Positioning
PIR Activator 376A-3 ONLY.
Plan view
100
o
approx.
5 - 7m
4 - 6m
3 - 4m
Side view
60
o
approx.
5 - 7m
3 - 4m
PIR & Touch Activator
Battery jumper tab. ON OFF
*With the PIR activator version determine
a suitable location for the sensor. Avoid
area with direct sunlight, vibrating
surfaces or near forced air from heaters
and ventilation systems.
Battery
LIVE IN
NEUTRAL
LIVE OUT
Battery
Battery
*Optional wire for blue indicator
ring on pushbutton activators only.
Battery
LIVE IN
LIVE OUT
Battery
Battery
*Optional wire for blue indicator
ring on pushbutton activators only.
DIL
switches
Battery
DIL
switches
DIL
switches
Battery
DIL
switches
Battery
DIL
switches
Battery
DIL
switches
NEUTRAL
Pushbutton & Touch Button Activators – Press or
Touch the activator button once to remotely trigger
the associated master timer to switch ON. This will
switch the light source or appliance ON and initiate
the pre-set timing delay sequence.
PIR Activator only – Leave the area and wait for the
Master Timer to switch OFF providing no further
movement are detected, re-enter the area and the PIR
will detect movement and trigger the unit initiating
the timing sequence on the Master unit it is attached
to and switch the light source or appliance ON.
All timers – At any time during the working of the
light source, load or appliance, the pushbutton/
touchpad can be pressed to reset the timing
sequence on the master unit to the originally set
time, e.g. When the timing period is 30 minutes,
if the pushbutton/touchpad is pressed 15 minutes
into sequence, the timer will restart for a further
30 minutes. To prematurely end the timing of the
Push/Touch master timer, press and hold the
pushbutton/touch for 2.5 seconds and the pre-set
Diagram 1
2 wire Master with Activator.
Diagram 2
3 wire Master with Activator.
Battery
LIVE IN
NEUTRAL
LIVE OUT
Battery
Battery
*Optional wire for blue indicator
ring on pushbutton activators only.
Battery
LIVE IN
LIVE OUT
Battery
Battery
*Optional wire for blue indicator
ring on pushbutton activators only.
DIL
switches
Battery
DIL
switches
DIL
switches
Battery
DIL
switches
Battery
DIL
switches
Battery
DIL
switches
NEUTRAL
LIVE IN
NEUTRAL
LIVE OUT
5 - 7m
4 - 6m
5 - 7m
3 - 4m
5 - 7m
4 - 6m
5 - 7m
3 - 4m
LIVE IN
LIVE OUT
NEUTRAL
7 metres approx.
2.4 metres
7 metres approx.
CEILING
FLOOR
LIVE IN
NEUTRAL
LIVE OUT
LIVE IN
LIVE OUT
Battery
LIVE IN
LIVE OUT
DIL
switches
Battery
NEUTRAL
2 wire Push, Touch
& PIR Master
Product codes
350A-1 / 360A-1 / 376A-1
Push, Touch
& PIR Activator
Product codes
350A-3 / 360A-3 / 376A-3
Brook House,
Dunmurry Industrial Estate,
Dunmurry,
Belfast BT17 9HU
T +44 (0)28 9061 6505
F +44 (0)28 9061 6518
E info@elkay.co.uk elkay.co.uk
BROOK DESIGN HARDWARE LTD
BDH
B
DH
BROOK DESIGN
HARDWARE LTD
BDHBROOK DESIGN
HARDWARE LTD
BDH
BROOK DESIGN
HARDWARE LTD
BDH
Technical Helpline
For further help or assistance or information on this or other products in the range
please call the Elkay Technical team on +44 (0)28 9061 6505. Please call the Technical
helpline before returning any products to your stockist. In the unlikely event that you
have to return your product, please ensure you switch the battery o rst. These
instructions are available in other languages. Please refer to our website www.elkay.co.uk
Instrukcje są również dostępne w innych językach. Prosimy o zapoznanie się z
nasstroną internetową www.elkay.co.uk lub www.elkaypolska.pl
Important Notice
All wiring should be carried out by a
competent person or a qualified electrician
and should be fitted to current IEE wiring
regulations BS 7671.The circuit should
be isolated before carrying out any work.
Failure to adhere to the instructions will
invalidate the warranty.
Elkay (Europe), 51C Milicka, Trzebnica, 55-100, Poland
Battery
LIVE IN
NEUTRAL
LIVE OUT
Battery
Battery
*Optional wire for blue indicator
ring on pushbutton activators only.
Battery
LIVE IN
LIVE OUT
Battery
Battery
*Optional wire for blue indicator
ring on pushbutton activators only.
DIL
switches
Battery
DIL
switches
DIL
switches
Battery
DIL
switches
Battery
DIL
switches
Battery
DIL
switches
NEUTRAL
LIVE IN
NEUTRAL
LIVE OUT
5 - 7m
4 - 6m
5 - 7m
3 - 4m
5 - 7m
4 - 6m
5 - 7m
3 - 4m
LIVE IN
LIVE OUT
NEUTRAL
7 metres approx.
2.4 metres
7 metres approx.
CEILING
FLOOR
LIVE IN
NEUTRAL
LIVE OUT
LIVE IN
LIVE OUT
Battery
LIVE IN
LIVE OUT
DIL
switches
Battery
NEUTRAL
Battery
LIVE IN
NEUTRAL
LIVE OUT
Battery
Battery
*Optional wire for blue indicator
ring on pushbutton activators only.
Battery
LIVE IN
LIVE OUT
Battery
Battery
*Optional wire for blue indicator
ring on pushbutton activators only.
DIL
switches
Battery
DIL
switches
DIL
switches
Battery
DIL
switches
Battery
DIL
switches
Battery
DIL
switches
NEUTRAL
Battery
LIVE IN
NEUTRAL
LIVE OUT
Battery
Battery
*Optional wire for blue indicator
ring on pushbutton activators only.
Battery
LIVE IN
LIVE OUT
Battery
Battery
*Optional wire for blue indicator
ring on pushbutton activators only.
DIL
switches
Battery
DIL
switches
DIL
switches
Battery
DIL
switches
Battery
DIL
switches
Battery
DIL
switches
NEUTRAL
3 wire Push, Touch
& PIR Master
Product codes
3875A-1 / 2235A-1 / 370A-1 / 320A-1
Push, Touch
& PIR Activator
Product codes
350A-3 / 360A-3 / 376A-3
*Optional on Pushbutton
timers only - The switch-live
link can be omitted
(No blue indicator ring).
*Optional on Pushbutton
timers only - The switch-live
link can be omitted
(No blue indicator ring).
delay time will time out after 60 seconds and switch
OFF, during this time-out period the red LED on the
master will fl ash continuously. The blue locator ring
will then illuminate once the light or appliance is
switched OFF.
PIR Activator only – In standard operation the
PIR Activator will now sense body heat when passing
through the detection zone. Each time the
Activator PIR is triggered the red LED will fl ash once
and reset the timer on the master unit it is connected
to, back to the start of the timing period. The unit
will then wait 10 to 15 seconds approximately before
allowing the PIR unit to sense and re-trigger the
timing period again.
If no one is present in the room or the detection
zone is not passed through during its set time
period, the timer will time out turning off the lights
or appliance and the blue indicator ring will light up.
The Activator PIR unit will only trigger the lights or
application if the ambient light level is below
what has been set on the lux level adjustment.
  • Page 1 1
  • Page 2 2

Elkay 360A-1 Instrukcja obsługi

Typ
Instrukcja obsługi

w innych językach