CONDTROL Dalmierz laserowy Vector 100 Instrukcja obsługi

Kategoria
Zmierzenie
Typ
Instrukcja obsługi
23
Vector 100 CONDTROL Vector 100 CONDTROL
УКАЗАНИЯ ПО ТЕХНИКЕ БЕЗОПАСНОСТИ 49
НАЗНАЧЕНИЕ ПРИБОРА 50
КОМПЛЕКТАЦИЯ 50
ТЕХНИЧЕСКИЕ ХАРАКТЕРИСТИКИ 50
ОПИСАНИЕ ПРИБОРА 51
РАБОТА С ПРИБОРОМ 53
ИЗМЕРЕНИЯ 55
ВЫЧИСЛЕНИЯ 58
КОДЫ СООБЩЕНИЙ 68
УХОД И ЭКСПЛУАТАЦИЯ 69
УТИЛИЗАЦИЯ 69
ГАРАНТИЙНЫЕ ОБЯЗАТЕЛЬСТВА 70
СЕРВИС И КОНСУЛЬТАЦИОННЫЕ УСЛУГИ 70
ZALECENIA DOTYCZĄCE BEZPIECZEŃSTWA 71
PRZEZNACZENIЕ NARZĘDZIA 72
WYPOSAŻENIE 72
CHARAKTERYSTYKA TECHNICZNA 72
ОPIS NARZĘDZIA 73
РRACA Z NARZĘDZIEM 75
POMIARY 77
OBLICZENIA 80
КODY KOMUNIKATÓW 91
KONSERWACJA I EKSPLOATACJA 92
UTYLIZACJA 93
GWARANCJA 94
RU СОДЕРЖАНИЕ
PL SPIS TREŚCI
SAFETY REGULATIONS 4
INTENDED USE 4
DELIVERY PACKAGE 5
TECHNICAL SPECIFICATIONS 5
PRODUCT DESCRIPTION 6
OPERATION 8
MEASUREMENTS 10
CALCULATIONS 13
MESSAGE CODES 23
CARE AND MAINTENANCE 24
UTILIZATION 24
WARRANTY 25
EN CONTENT
SICHERHEITSHINWEISE 26
BESTIMMUNGSGEMÄSSER GEBRAUCH 27
LIEFERUMFANG 27
TECHNISCHE SPEZIFIKATIONEN 27
GERÄTEBESCHREIBUNG 29
GERÄTEBEDIENUNG 31
MESSUNGEN 33
BERECHNUNGEN 36
FEHLERCODES 46
PFLEGE 47
ENTSORGUNG 47
GARANTIE 47
WARTUNG UND REPARATUR 48
DE INHALT
User manual
LASER DISTANCE METER
4
EN
5
User manual
LASER DISTANCE METER
EN
Vector 100 CONDTROL Vector 100 CONDTROL
Congratulations on your purchase of laser distance meter Vector 100 CONDTROL.
Safety instructions can be found in the end of this user manual and should be
carefully read before you use the product for the first time.
SAFETY REGULATIONS
The user manual should be read carefully before you use the product for the first
time. Unintended use of the product can be dangerous for human’s health and
cause serious injury. Keep this user manual. If the product is given to somebody
for temporary use, be sure to enclose user manual to it.
- Do not misuse the product
- Do not remove warning signs and protect them from abrasion, because they
contain information about safe operation of the product.
The device belongs to laser product class 2 in accordance with EN60825-1.
Laser radiation!
Do not stare into beam
Class 2 laser
<1 mW 635nm
EN60825-1: 2007-03
- Do not look into the laser beam or its reflection, with unprotected eye or
through an optical instrument. Do not point the laser beam at people or animals
without the need. You can dazzle them.
- To protect your eyes close them or look aside.
- It is prohibited to disassemble or repair the product yourself. Entrust product
repair to qualified personnel and use original spare parts only.
- Do not use the product in explosive environment, close to flammable materials.
- Avoid heating the batteries to avoid the risk of explosion and electrolyte
leakage. In case of liquid contact with skin, wash it immediately with soap and
water. In case of contact with eyes, flush with clean water during 10 minutes and
consult the doctor.
INTENDED USE
Laser distance meters Vector 100 is intended to measure distance, to calculate
area and volume of measured objects, perform calculations by tilt sensor
and Pythagoras Theorem, point to point measurements, store results of
measurement/calculation in memory and also transmit via Bluetooth. The
product is suitable for use at both indoor and outdoor building areas.
DELIVERY PACKAGE
The delivery package includes:
1. Laser distance meter – 1pc.
2. Carry pouch with a strap - 1 pc.
3. User manual - 1 pc.
5. USB charger - 1 pc.
TECHNICAL SPECIFICATIONS
Measuring range* 0,05–100 m
Measuring accuracy ** ± 1,5 mm
Smallest unit displayed 1 mm
Display backlight +
Reference point Front, rear, tripod, end-piece
Continuous measurement (tracking) +
Max./min. value +
Addition/subtraction +
Area/wall surface/volume +
Calculation of horizontal distance by tilt sensor +
Calculations by Pythagoras’ theorem +
Point to point measurement +
Bluetooth +
Timer +
Digital vial +
Memory up to 30 values
Laser Class II, 635nm, <1 mW
Operating temperature –10 °С ... +50 °С
Storage temperature –20 °С ... +60 °С
Dust and water protection IP54
User manual
LASER DISTANCE METER
6
EN
7
User manual
LASER DISTANCE METER
EN
Vector 100 CONDTROL Vector 100 CONDTROL
PRODUCT DESCRIPTION
Display
1. Display
2. Keyboard
3. A hole for the strap
4. End-piece
5. Tripod thread 1/4’
6. Mini-USB connector for charging
Power supply 3,7 V 850 mAh Li-ion
rechargeable battery
Dimensions 119*46*28 mm
Weight 0,1 kg
* Use a reflective plate to increase the measurement range during daylight or if the
target has poor reflection properties.
** Accuracy can decrease in unfavorable conditions, such as intense sunshine or
when measurements are made against glossy or transparent surfaces, moving
objects, objects with rough surface.
In unfavorable conditions or when measured distance is over 100 m the maximum
permissible accuracy is calculated in the following way:
± (Y + 0,25хDх10-3) mm, where
D (mm) - measured distance
Y (mm) - permissible accuracy according to technical data.
6
1
2
3
5
4
1. Main line for displaying
measuring results
2. Additional lines for
displaying measuring results
3. Indication of tilt angle
4. Indication of the mode
5. Indication of Bluetooth
6. Indication of battery charge
level
7. Indication of reference point
8. Indication of measuring unit
2
7
8
1
35
6
4
User manual
LASER DISTANCE METER
8
EN
9
User manual
LASER DISTANCE METER
EN
Vector 100 CONDTROL Vector 100 CONDTROL
Functions of buttons
Button Short press Long press
Switch on the device
Switch on the laser beam
Single distance measurement
Continuous
measurement
(tracking)
Subtraction
Down (in menu of functions)
Set response time in timer (decrease value)
Flip through measuremens in memory
(backwards)
Addition
Up (in menu of functions)
Set response time in timer (increase value)
Flip through measurements in memory
(forward)
Enter the menu Change
reference point
Stop measurement/clear/exit the mode/exit
the menu
Switch off the
device
+
simultaneously
Select measuring unit
OPERATION
Battery charging
Charge level is shown on display. Charge the battery when symbol appears
on the display. Use USB charger delivered in the set only. It is not recommended
to use the product while charging. It takes approximately 3 hours to fully charge
the batteries.
Switch on/off the device
To switch on the device short press .
To switch off the device press and hold during 1 second.
Measuring unit
Short press and simultaneously.
Short press buttons and to select required measuring
unit – m/ft/in. Short press to confirm and return to single distance
measurement mode.
Reference point
Press and hold button during 1 second to select the reference
point. Appropriate indicator will appear on the display.
- Front - Tripod
- Rear (default) - End-piece
Menu
Short press button to enter
the menu of functions:
Short press buttons (down),
(up) to select the function. Selected
function will be framed in grey color.
S h o r t p r e s s to confirm. Selected
function will be activated.
S h o r t p r e s s to exit the menu.
User manual
LASER DISTANCE METER
10
EN
11
User manual
LASER DISTANCE METER
EN
Vector 100 CONDTROL Vector 100 CONDTROL
MEASUREMENTS
Single distance measurement
Short press The device will switch on.
Short press Laser beam will switch on.
Point the laser beam at the object of measurement.
Short press Make a single distance measurement.
- Measurement result
Short press Delete the last measurement result.
Continuous distance measurement (Tracking)
Press and hold
during 2 seconds
Activate continuous measurement mode. The laser
beam is also activated. Symbol appears
on the display.
- maximal value
- minimal value
- current value
Short press
or
Stop continuous measurement.
The last measured values are shown on the display.
Short press Exit the mode.
User manual
LASER DISTANCE METER
12
EN
13
User manual
LASER DISTANCE METER
EN
Vector 100 CONDTROL Vector 100 CONDTROL
Addition/subtraction
Short press Turn on the laser beam. Aim the product at
measured object.
Short press Take the first measurement. Measuring result
appears in the main line.
Short press
for addition or
for subtraction
The symbol of addition or subtraction
will appear on the display.
Short press Turn on the laser beam. 1st measurement moves
to the 2nd line.
Short press Take the second measurement.
- 1st measurement
- 2nd measurement
- result of addition/subtraction
To do addition/subtraction of more than 2 measurements short press
and perform the above mentioned operations required number of times.
Short press Exit the mode.
CALCULATIONS
Area
Short press
1 time. Enter menu of functions.
Short press / Select function “Area”
Short press Symbol will appear on the display.
Laser beam is on.
Short press Make the first measurement (length).
Short press Make the second measurement (width).
- length
- width
- area
Short press Exit the mode.
User manual
LASER DISTANCE METER
14
EN
15
User manual
LASER DISTANCE METER
EN
Vector 100 CONDTROL Vector 100 CONDTROL
Wall surface
Short press Enter menu of functions.
Short press / Select function “Wall surface
Short press Symbol will appear on the display.
Laser beam is on.
Short press Make the first measurement (height).
Short press Make the second measurement (length 1).
Short press Make the third measurement (length 2).
- height
- length 1
- length 2
- wall surface
3rd, 4th, 5th etc. measurements can be done unlimited number of times. Each
new wall surface is added to previously calculated wall surface result.
Short press Exit the mode.
Volume
Short press Enter menu of functions.
Short press / Select function “Volume
Short press Symbol will appear on the display.
Laser beam is on.
Short press Make the first measurement (length).
Short press Make the second measurement (width).
Short press Make the third measurement (height).
-length
-width
- height
-volume
Short press Exit the mode.
User manual
LASER DISTANCE METER
16
EN
17
User manual
LASER DISTANCE METER
EN
Vector 100 CONDTROL Vector 100 CONDTROL
Calculation of horizontal distance by tilt sensor
Short press Enter menu of functions.
Short press / Select function “Calculation
of horizontal distance by tilt sensor
Short press Symbol will appear on display. Laser beam
is on.
Short press Take first measurement (hypotenuse).
- tilt angle value (measured)
- hypotenuse (measured)
- cathetus/vertical distance (calculated)
- cathetus/horizontal distance (calculated)
Short press Exit the mode.
Point to point measurement
Short press Enter menu of functions.
Short press / Select function “Point to point
Short press Symbol will appear on display.
Laser beam is on.
Short press Make the first measurement (distance to point A)
Short press Make the second measurement (distance to
point B)
– distance to point A (measured)
– distance to point B (measured)
– distance between points A and B (calculated)
Short press Exit the mode.
User manual
LASER DISTANCE METER
18
EN
19
User manual
LASER DISTANCE METER
EN
Vector 100 CONDTROL Vector 100 CONDTROL
Calculation of distance by 2 additional measurements (Pythagoras’ theorem)
Short press Enter menu of functions.
Short press / Select function “Calculation of distance
by 2 additional measurements
Short press Symbol will appear on display.
Laser beam is on.
Short press Make the first measurement (hypotenuse).
Short press Make the second measurement (cathetus 1)
- hypotenuse (measured)
- cathetus 1 (measured)
- cathetus 2 (calculated)
Short press Exit the mode.
Calculation of distance by 3 additional measurements (sum of cathetuses)
Short press Enter menu of functions.
Short press /
Select function “Calculation of distance
by 3 additional measurements
(sum of cathetuses)
Short press Symbol will appear on display.
Short press Make the first measurement (hypotenuse 1).
Short press Make the second measurement (cathetus).
Short press Make the 3rd measurement (hypotenuse 2).
– hypotenuse 1 (measured)
– cathetus (measured)
– hypotenuse 2 (measured)
– cathetus (calculated)
Short press Exit the mode.
User manual
LASER DISTANCE METER
20
EN
21
User manual
LASER DISTANCE METER
EN
Vector 100 CONDTROL Vector 100 CONDTROL
Calculation of distance by 3 additional measurements
(subtraction of 2 cathetuses)
Short press Enter menu of functions.
Short press /
Select function “Calculation of distance by 3
additional measurements (subtraction of 2
cathetuses)”
Short press Symbol will appear on display.
Laser beam is on.
Short press Make the first measurement (hypotenuse 1).
Short press Make the second measurement (hypotenuse 2).
Short press Make the 3rd measurement (cathetus).
– hypotenuse 1 (measured)
– hypotenuse 2 (measured)
– cathetus (measured)
– cathetus (calculated)
Short press Exit the mode.
Digital vial
Short press Enter menu of functions.
Short press / Select function “Digital vial
Short press Enter digital vial mode. Aim the product in appropriate
direction using angle readings shown on the display.
Short press Make a measurement.
- measuring result
Short press Exit the mode.
User manual
LASER DISTANCE METER
22
EN
23
User manual
LASER DISTANCE METER
EN
Vector 100 CONDTROL Vector 100 CONDTROL
Memory
Short press Enter menu of functions.
Short press / Select function “Memory
Short press
A number of the measurement/calculation result is
reflected in the symbol on the display.
Short press / Flip through saved measurement/calculation results.
Short press Exit the mode.
MESSAGE CODES
While operation, the following codes/symbols may appear on the display:
Message Cause Solution
ERR 1 Laser signal is too weak. Use a reflective plate.
ERR 2 Laser signal is too strong. Use a reflective plate.
ERR 3 Low battery. Charge the battery.
ERR 4 Failure of memory. Contact the service center.
ERR 5 Failure of calculation by
Pythagoras Theorem. Repeat the measurement.
ERR 6
Measuring result exceeds
permissible measuring
range.
Please change to longer distance
product.
ERR 7 Failure of tilt sensor. Please contact service center.
Timer
Short press Enter menu of functions.
Short press / Select function “Timer
Short press Symbol will appear on display.
Default value is 5 seconds.
Short press / Set response time.
Short press
Start the timer.
As soon as response time runs out, measurement
will be taken.
Measurement result will appear in the main line.
Short press Exit the mode.
Bluetooth
Short press Enter menu of functions.
Short press / Select function “Bluetooth”
Short press Switch on Bluetooth. Symbol turns blue.
Symbol appears on the display on the main
screen. Activate Bluetooth in the smartphone,
tablet PC or laptop. For further operation use
application Smart Measure CONDTROL.
Short press
Switch off Bluetooth. Symbol turns grey.
Symbol will disappear
from the display on the main screen.
User manual
LASER DISTANCE METER
24
EN
25
User manual
LASER DISTANCE METER
EN
Vector 100 CONDTROL Vector 100 CONDTROL
CARE AND MAINTENANCE
Attention! The instrument is a precise device and requires careful handling. The
following recommendations will extend the life of the product:
- Do not point the product at the sun.
- Protect the product from bumps, falls, and excessive vibration; do not let liquids,
construction dust and foreign objects get inside the product.
- Do not expose the product to extreme temperatures.
- If liquids get inside the product first remove the batteries, then contact the
service center.
- Do not store or use the product under high humidity conditions for a long time.
- Clean the product with soft wet cloth.
- Keep device optics clean and protect it from mechanical damage.
- Сarry out control measurements occasionally, especially if the product is subject
to excessive mechanical or other impact, before and after taking important
measurements.
UTILIZATION
Expired tools, accessories and package should be passed for waste recycle. Please
send the product to the following address for proper recycle:
CONDTROL GmbH
Wasserburger Strasse 9
84427 Sankt Wolfgang
Germany
Do not throw the product in municipal waste!
According to European directive 2002/96/ЕC expired measuring tools and their
components must be collected separately and submitted to environmentally
friendly recycle of wastes.
WARRANTY
All CONDTROL GmbH products go through post-production control and are
governed by the following warranty terms. The buyer’s right to claim about defects
and general provisions of the current legislation do not expire.
1) CONDTROL GmbH agrees to eliminate all defects in the product, discovered
during the warranty period, that represent the defect in material or workmanship
in full volume and at its own expense.
2) The warranty period is 36 months and starts from the date of purchase by the
end customer (see the original supporting document).
3) The warranty dösn’t cover defects resulting from wear and tear or improper
use, malfunction of the product caused by failure to observe the instructions of
this user manual, untimely maintenance and service and insufficient care, the use
of non-original accessories and spare parts. Modifications in design of the product
relieve the seller from responsibility for warranty works. The warranty dös not
cover cosmetic damage, that dösn’t hinder normal operation of the product.
4) CONDTROL GmbH reserves the right to decide on replacement or repair of the
device.
5) Other claims not mentioned above, are not covered by the warranty.
6) After holding warranty works by CONDTROL GmbH warranty period is not
renewed or extended.
7) CONDTROL GmbH is not liable for loss of profit or inconvenience associated with
a defect of the device, the rental cost of alternative equipment for the period of
repair.
This warranty applies to German law except provision of the United Nations
Convention on contracts for the international sale of goods (CISG).
In warranty case please return the product to retail seller or send it with defect
description to the following address:
CONDTROL GmbH
Wasserburger Strasse 9
84427 Sankt Wolfgang
Germany
Bedienungsanleitung Bedienungsanleitung
LASER-ENTFERNUNGSMESSER
26
DE
27
LASER-ENTFERNUNGSMESSER
DE
Vector 100 CONDTROL Vector 100 CONDTROL
Herzlichen Glückwunsch zum Kauf Ihres CONDTROL Vector 100. Die
Sicherheitshinweise finden Sie am Ende der deutschen Anleitung. Bitte lesen Sie
diese sorgltig, bevor Sie das Get das erste Mal verwenden.
SICHERHEITSHINWEISE
Bitte lesen und befolgen Sie alle Anweisungen r die sichere Verwendung Ihres
Geräts. Nichtbeachten der Anleitung kann zu Verletzungen, Materialschäden,
finanziellem oder ökologischem Schaden führen. Bewahren Sie diese
Bedienungsanleitung auf. Bei der Übergabe des Gerätes legen Sie diese Anleitung
bei.
- Das Gerät darf nur zweckmäßig verwendet werden.
- Warnschilder müssen stets sichtbar und erkennbar am Gerät angebracht sein.
Das Gerät erzeugt Strahlung der Laserklasse 2 gemäß EN60825-1 mit der
Wellenlänge 635nm.
LASERSTRAHLUNG!
Nicht in den Strahl blicken
Laserklasse 2
<1 mW 635nm
EN60825-1: 2007-03
Sie erhalten Ihr Get mit einem Warnschild in Englisch. Bitte beachten Sie das
hier abgebildete Warnschild in Deutsch.
Sie können Strahlung ausgesetzt sein, wenn Sie die Anweisungen dieser
Bedienungsanleitung nicht befolgen.
- Richten Sie den Laserstrahl nicht auf Personen oder Tiere. Blicken Sie selbst
nicht in den Laserstrahl, insbesondere nicht mit optischen Instrumenten. Ihr
Augenlicht ist in Gefahr.
- Die Reparatur und Wartung darf nur durch qualifiziertes Fachpersonal erfolgen,
das originale Ersatzkomponenten einsetzt. Kinder dürfen das Gerät nur unter
Aufsicht benutzen, um die Sicherheit für sich selbst und andere Personen zu
gewährleisten.
- Verwenden Sie das Gerät nicht in der Nähe von brennbaren Stoffen, da im Gerät
Funken entstehen können, und halten Sie ausreichend Abstand zu Wärmequellen.
- Platzieren Sie die Batterien des Gerätes nie in der Nähe von Hitze oder Feuer, um
das Risiko von Explosionen und Verletzungen zu reduzieren.
- Im Fall einer Explosion der Batterien besteht das Risiko von Verletzungen durch
Trümmer und Chemikalien. Löschen Sie die Stellen sofort mit Wasser.
Unter extremen Bedingungen können Batterien auslaufen. Bei Kontakt der
Flüssigkeit mit den Augen, reinigen Sie diese sofort mindestens zehn Minuten
lang mit sauberem Wasser und suchen Sie anschließend einen Arzt auf.
BESTIMMUNGSGEMÄSSER GEBRAUCH
Der Laser-Entfernungsmesser Vector 100 ist zum Messen von Distanzen,
Berechnung von Flächen und Volumina sowie zum Bestimmen einer Strecke
mit Neigungsmessung und Pythagoras-Satz, Punkt-zu-Punkt Messungen,
Speicherung von Mess-/Berechnungsergebnissen sowie deren Übertragung
via Bluetooth bestimmt. Das Gerät verfügt über Bluetooth-Funktion zur
Übertragung der Werte in Ihre Software. Es ist für den Innen - und Auß enbereich
geeignet.
LIEFERUMFANG
Der Lieferumfang des Entfernungsmessers umfasst:
1. Laser-Entfernungsmesser
2. Schutztasche mit Hand-/Gurtschlaufe
3. Bedienungsanleitung
4. USB-Ladegerät
TECHNISCHE SPEZIFIKATIONEN
Reichweite* 0,05–100 m
Messgenauigkeit ** ± 1,5 mm
Kleinste Anzeige 1 mm
Displaybeleuchtung +
Referenzpunkt bestimmen Vorderkante, Hinterkante, Stativ,
ausklappbares Endstück
Dauermessung (Tracking) +
Max./min. -Messungen +
Addition/Subtraktion von Abmessungen +
Fläche/Wandfläche/Volumen +
Berechnungen mit Neigungsmesser +
Berechnungen mit Pythagoras-Satz +
Punkt – zu – Punkt - +
Messung +
Bluetooth +
Bedienungsanleitung Bedienungsanleitung
LASER-ENTFERNUNGSMESSER
28
DE
29
LASER-ENTFERNUNGSMESSER
DE
Vector 100 CONDTROL Vector 100 CONDTROL
Timer +
Digitale Wasserwaage +
Integrierter Speicher Bis zu 30 Werte
Lasertyp Laserklasse II, 635nm, <1 mW
Betriebstemperatur –10 °С ... +50 °С
Lagertemperatur –20 °С ... +60 °С
Wasser- und Staubschutz IP54
Akkus 3,7 V 850 mAh Li-ion
aufladbarer Akku
Abmessungen 119*46*28 mm
Gewicht 0,1 kg
* Verwenden Sie eine Zieltafel, um die Reichweite bei Tageslicht bei schlechter
Reflexion des Messzieles zu vergrößern.
** Unter ungünstigen Bedingungen wie z.B. direktem Sonnenlicht oder schlecht
reflektierender Oberfläche, kann die Ungenauigkeit steigen. Es kann zu
Messfehlern kommen wenn Sie gegen reinstes (staubfrei) Glas oder gegen andere
farblose und durchsichtige Stoffe messen. Stark glänzende Oberflächen können
ebenfalls zu Fehlmessungen beitragen; der Laserstrahl wird eventuell abgelenkt.
Unter ungünstigen Bedingungen und bei Entfernungen über 100 m beträgt die
zulässige Abweichung:
± (Y + 0,25хDх10-3)mm:
D (mm) - zu messende Entfernung
Y (mm) - zulässige Messgeräteabweichung.
1. Display
2. Tastatur
3. Aufnahme Tragschlaufe
4. Aufklappbares Endsck
5. 1/4’’ - Stativgewinde
6. Micro-USB – Buchse für Ladegerät
6
1
2
3
5
4
GERÄTEBESCHREIBUNG
Bedienungsanleitung Bedienungsanleitung
LASER-ENTFERNUNGSMESSER
30
DE
31
LASER-ENTFERNUNGSMESSER
DE
Vector 100 CONDTROL Vector 100 CONDTROL
Funktionen der Tasten
Taste Kurzes Dcken Langes Drücken
Gerät einschalten
Laseraktivierung
Einzelmessung
Dauermessung
(Tracking)
Subtrahieren
AB (im Funktionsmenü)
Einstellen der Vorlaufzeit in Timer
(Wertminderung)
Durchblättern der Messergebnisse im
Speicher (rückwärts)
Addieren
AUF (im Funktionsmenü)
Einstellen der Vorlaufzeit in Timer
(Wertsteigerung)
Durchblättern der Messergebnisse im
Speicher (vorwärts)
Menü aufrufen Referenzpunkt
auswählen
Messung stoppen/Werte löschen/Modus
verlassen/Menü verlassen
Gerät
ausschalten
+
gleichzeitig
Meßeinheit wählen
GERÄTEBEDIENUNG
Akkus laden
Der Akku-Ladezustand wird auf dem Display angezeigt. Laden Sie die Akkus auf,
wenn das Symbol permanent auf dem Bildschirm blinkt. Benutzen Sie
das mitgelieferte Ladegerät, um Ihren Laserentfernungsmesser aufzuladen. Das
Gerät kann während des Ladens nicht verwendet werden. Das Get wird in ca. 3
Stunden völlig aufgeladen.
Display
1. Hauptzeile für Anzeige der Messergebnisse
2. Zutzliche Messwert-/Ergebnisszeilen
3. Anzeige für Neigungswinkel
4. Modusanzeige
5. Anzeige für Bluetooth
6. Akku-Ladezustandsanzeige
7. Anzeige für Referenzpunkt
8. Anzeige für Messeinheit
2
7
8
1
35
6
4
Bedienungsanleitung Bedienungsanleitung
LASER-ENTFERNUNGSMESSER
32
DE
33
LASER-ENTFERNUNGSMESSER
DE
Vector 100 CONDTROL Vector 100 CONDTROL
Bestätigen Sie die Funktion mit dem kurzen Drücken der Taste .
Die gewählte Funktion wird aktiviert.
Verlassen Sie den Menü mit kurzem Dcken der Taste .
Ein- /Ausschalten
Drücken Sie die Taste , um das Gerät einzuschalten.
Drücken und halten Sie die Taste 1 Sekunde gedrückt, um das Gerät
auszuschalten.
Messeinheit wählen
Wählen Sie die Messeinheit durch gleichzeitiges Drücken der Tasten
und . Mit kurzem Drücken der Tasten und wählen
Sie die gewünschte Meßeinheit – m/ft/in (Meter/Fuß/Zoll). Mit kurzem Drücken
der Taste bestigen Sie die Einstellung und wechseln zurück in den
Modus der Einzelmessungen.
Messebene festlegen
D r ü c k e n u n d h a l t e n S i e d i e T a s t e 1 Sekunde gedrückt, um
einen Messausgangspunkt zu wählen. Das entsprechende Symbol erscheint auf
dem Display.
- Vorderkante
- Stativ
Me
Drücken Sie kurz die Taste ,
um in den Menümodus zu wechseln:
M i t T a s t e n ( A B ) , (AUF)
wählen Sie die gewünshte Funktion aus. Die
gewählte Funktion wird mit einem grauen
Rahmen angezeigt .
MESSUNGEN
Einzelmessungen
Kurzes Dcken Einschalten des Gerätes.
Kurzes Dcken Laseraktivierung. Auf das Objekt zielen, dessen
Entfernung gemessen wird.
Kurzes Dcken Messen.
- Messergebnis
Kurzes Dcken Das letzte Messergebnis löschen.
- Hinterkante
(standardmäßig)
- Ausklappbares
Endstück
Bedienungsanleitung Bedienungsanleitung
LASER-ENTFERNUNGSMESSER
34
DE
35
LASER-ENTFERNUNGSMESSER
DE
Vector 100 CONDTROL Vector 100 CONDTROL
Dauermessungen (Tracking)
Drücken und 2 Sekunden
gedckt
halten
Aktivierung des Tracking - Modus.
Laseraktivierung. Das Symbol erscheint
auf dem Display.
- Maximalwert
- Minimalwert
- Aktueller Wert
Kurzes Dcken
oder
Dauermessung stoppen.
Der letzte gemessene Wert wird auf dem Display
angezeigt.
Kurzes Dcken Tracking – Modus verlassen.
Addieren/Subtrahieren
Kurzes Dcken Aktivierung des Laserstrahls. Zielen Sie auf das
Objekt, dessen Entfernung Sie messen wollen.
Kurzes Dcken Die erste Messung. Das Ergebnis erscheint in der
Hauptzeile.
Kurzes Dcken für
Addieren oder für
Subtrahieren
Die Anzeige für Addieren oder
Subtrahieren erscheint auf dem Display.
Kurzes Dcken Aktivierung des Laserstrahles. Das letzte
Messergebnis wird nun in der zweiten Zeile
angezeigt.
Kurzes Dcken Die zweite Messung.
- das Messergebnis der ersten
Messung
- das Messergebnis der zweiten
Messung
- Ergebnis der Addition/ Subtraktion von zwei
Messwerten
Um mehrere Messwerte zu addieren/subtrahieren, die Taste drücken
und die letzten Optionen wiederholen.
Kurzes Dcken Modus verlassen.
Bedienungsanleitung Bedienungsanleitung
LASER-ENTFERNUNGSMESSER
36
DE
37
LASER-ENTFERNUNGSMESSER
DE
Vector 100 CONDTROL Vector 100 CONDTROL
BERECHNUNGEN
Fläche
K u r z e s D r ü c k e n d e r T a s t e
1 Mal. Öffnen des Funktionsmenüs.
Kurzes Dcken
/ Die Funktion “Fläche wählen.
Kurzes Dcken Das Symbol erscheint auf dem Display. Der
Laserstrahl ist aktiviert.
Kurzes Dcken Die erste Messung (Länge).
Kurzes Dcken Die zweite Messung (Breite).
- Länge
- Breite
- Fläche
Kurzes Dcken Modus verlassen.
Wandfläche
Kurzes
Drücken Öffnen des Funktionsmenüs.
Kurzes Dcken
/ Die Funktion “Wandfche” wählen.
Kurzes Dcken Symbol erscheint auf dem Display. Der
Laserstrahl ist aktiviert.
Kurzes Dcken Die erste Messung (Höhe).
Kurzes Dcken Die zweite Messung (Länge 1).
Kurzes Dcken Die dritte Messung (Länge 2).
- Höhe
- Länge 1
- Länge 2
- Wandfläche
Die 3., 4., 5. und weiteren Messungen können mehrmals gemacht werden.
Jedes weitere Ergebnis der Wandflächenberechnung wird zu dem
vorhergehenden addiert.
Kurzes Dcken Modus verlassen.
Bedienungsanleitung Bedienungsanleitung
LASER-ENTFERNUNGSMESSER
38
DE
39
LASER-ENTFERNUNGSMESSER
DE
Vector 100 CONDTROL Vector 100 CONDTROL
Volumen
Kurzes
Drücken Öffnen des Funktionsmenüs.
Kurzes Dcken
/ Die Funktion Volumen” hlen.
Kurzes Dcken Symbol erscheint auf dem Display.
Der Laserstrahl ist aktiviert.
Kurzes Dcken Die erste Messung (Länge).
Kurzes Dcken Die zweite Messung (Breite).
Kurzes Dcken Die dritte Messung (Höhe).
-Länge
-Breite
- Höhe
-Volumen
Kurzes Dcken Modus verlassen.
Bestimmen einer horizontalen Strecke mit einer Neigungsmessung
Kurzes
Drücken Öffnen des Funktionsmes.
Kurzes Dcken
/
Die Funktion “Bestimmen einer
horizontalen Strecke mit einer
Neigungsmessung“ wählen
Kurzes Dcken Symbol erscheint auf dem Display.
Der Laserstrahl ist aktiviert.
Kurzes Dcken Die erste Messung (Hypotenuse ).
- Neigungswinkel (gemessen)
- Hypotenuse (gemessen)
- Kathete/vertikale Strecke (berechnet)
- Kathete /horizontale Strecke (berechnet)
Kurzes Dcken Modus verlassen.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49

CONDTROL Dalmierz laserowy Vector 100 Instrukcja obsługi

Kategoria
Zmierzenie
Typ
Instrukcja obsługi