Intertherm Vent Alarm System for Sloped Roof Kit Instrukcja instalacji

Typ
Instrukcja instalacji
Installation Instructions
914750 Sloped Roof Kit
VentAlarm
System
VentilAire IV Attic Ventilator Monitoring System
Figure 1. Wiring Diagram
GENERAL
These instructions are primarily intended to assist qualified
individuals experienced in the proper installation of this
appliance. Some local codes require licensed installation/
service personnel for this type of equipment. Read all
instructions carefully before starting the installation.
OPERATION
Your attic ventilator is equipped with an audible/visual
alarm system which monitors the operation of the attic
ventilator motor. In the event a motor failure would occur
the alarm will notify you with the sounding of a buzzer and
with a red service light on the alarm unit. The alarm unit
may be mounted in the furnace or other remote location of
the home.
If the motor fails the alarm can be turned off by moving the
Black switch to the Audible Alarm “OFF” position until the
unit is serviced. The red indicator light will remain lit until
the cause of the failure can be determined and fixed.
Once the problem has been corrected the alarm switch
should be moved back to the Audible Alarm “ON” position.
This will reactivate the system and turn the service light off.
INSTALLATION
All installations must be in accordance with these
instructions and all applicable Local and National
Electrical codes and standards.
ATTIC VENTILATOR ELECTRICAL WIRING
• 120 Volt Circuit
The roof vent cap assembly comes factory equipped
with the upper alarm circuit board installed. Follow
Instruction #8 - Electrical Hook-Up and the Wiring
Diagram on Page 4 of the VentilAire IV Installation
Instructions for the 120 Volt branch circuit wiring
portion of the installation (See Figure 1).
• 24 Volt Fan Signal Circuit
Carefully route standard two-wire low voltage cable
between the attic ventilator and the location of the
lower alarm circuit board. On interior furnace mount
applications use the thermostat low voltage wire
entrance for entry of the two-wire cable into the
cabinet.
Common wiring methods such as wire nuts, electrical
tape, etc., should be used on the Red and White fan
signal low voltage leads exiting the bottom of the attic
ventilator.
NOTE: Additional strain relief for these connections
using the supplied wire tie in the Extra Parts Package
or equivalent is required to ensure connections in the
field (See Figure 2). DO NOT TIE TOGETHER WITH
EXISTING WIRING KEEPING ENOUGH SLACK IN
THE CABLE TO ALLOW UPPER CAP AND MOTOR
ASSEMBLY TO BE REMOVED IF SERVICE IS
REQUIRED.
120 Volt
Field Wiring
Ground
See Note
24 Volt
Fan Signal Wiring
2 x 4 VentilAire
Electrical Box
White
Black
6 Pin
Connector
Red
White
Motor
Out
Motor
In
YL
YL
WH
WH
(Upper Alarm Board)
+
-
Fan Signal
White
Black
Blue
Red
Humidistat
Black
Switch 110˚F
Switch 35˚F
Yellow
White
Yellow
Red
White
Field Wiring
Unit Wiring
Note: Wire nuts field supplied
6
5
4
3
2
1
6
5
4
3
2
1
2
VentAlarm
System
Attic Ventilator Monitoring System
FAN
+-
Com
24 VAC
Two-Wire Cable from
Attic Ventilator
Red
Wht
LED
To Furnace
24 Volt
Power Supply
Audible
Alarm
Service
Required
Red w/Black
Stripe
Yellow w/Black Stripe
Buzzer
#6-32 x 1/4"
Machine Screw
On
Off
Switch
Knob
(Black)
Lower Alarm
Cover
Figure 4. VentAlarm
for VentilAire IV Ventilator
Figure 3.
Lower Alarm Circuit Board Mounting
Figure 2.
For “MG”, “MM”, “MB”, “MS”, and "M1" Series furnaces
it is recommended to locate the lower alarm board on
the left interior side panel of the furnace, next to the
thermostat low voltage wiring entrance just above the
furnace control panel.
For “E1” and "E2" Series furnaces it is recommended
to locate the lower alarm board on the right interior
side panel. The insulation has been removed for
installation of an alarm mounting bracket, NORDYNE
P/N-902933.
Mounting of the lower alarm circuit board using the
supplied template is recommended to ensure proper
alignment of the holes. Drill the appropriate diameter
holes for the application at the two designated locations
shown. Drill 3/32" holes for sheet metal mounting or 3/
16" holes for drywall or panel mounting (See Figure 3).
3/4" self drilling screws for sheet metal mounting or 1"
screws and anchors for drywall and panel mounting
have been provided in the Extra Parts Package.
LOWER ALARM CIRCUIT BOARD
The lower alarm circuit board comes equipped for mounting
to the interior of the furnace. It may also be wired for
remote wall mount applications using standard low voltage
thermostat wire.
Provisions have been made for the low voltage wiring to be
concealed on drywall and panel mount applications by
entering from behind the bottom of the circuit board. (See
mounting template for proper hole location.) On furnace
or alcove mounting applications the wiring will enter through
the bottom of the lower alarm board cover.
NOTE: For furnace mount applications the following lower
alarm board locations are recommended.
Alarm Board
Mounting Template
+
+
+
FAN
+-
Com
24 VAC
Red
Wht
LED
Ensure label is level when applying
Drill 3/32" dia. hole for sheet metal
mounting or 3/16" dia. hole when using
supplied anchors for drywall or panel
mounting.
For wall mount applications drill
a maximum 1/2" dia. hole
for remote cable entry.
Instructions
Buzzer
For drywall or panel
mounting use
supplied anchors.
(2 Required)
3/4" Screw w/Sheet Metal
or
1" Screw w/ Anchors
Red (2)
Wire Tie
White (2)
3
LOWER ALARM BOARD ELECTRICAL
WIRING
Fan Signal Wiring
For all furnace applications install the two-wire low voltage
cable from the attic ventilator to the two terminals on the
lower alarm circuit board marked “FAN” (See Figure 4).
ELECTRIC, GAS AND OIL FURNACES
24 Volt Power Supply
Furnace mount applications will use the supplied Red w/
Black stripe and Yellow w/ Black stripe wires for connecting
to the furnace 24 Volt power supply. See “LOW VOLTAGE
CONNECTIONS” for your specific furnace application.
For remote wall mount applications run standard two wire
thermostat wire from the lower alarm board location to the
furnace 24 Volt power supply. Use the two insulated crimp
terminals supplied in the Extra Parts Package for mounting
the cable to the lower alarm board.
LOW VOLTAGE CONNECTIONS
Gas Furnaces
MG/MM Series Sealed Combustion Gas Furnace
24 Volts is supplied using the Red (24V Hot) and
Yellow (24V Com) wires in the 6-pin thermostat plug.
The Yellow (24V Com) wire is marked with an
Accessory label.
MB Series Sealed Combustion Gas Gun Furnace
24 Volts is supplied using the Red (24V Hot) and
Yellow w/ Black stripe (24V Com) wires located on top
of the furnace control panel. The Yellow w/ Black
stripe (24V Com) wire is marked with an Accessory
label.
M1G/M1M/M1S Series
24 Volts is supplied using the red (24V Hot) and Gray
(24V Com) wires in the 6-pin thermostat plug.
Oil Furnaces
MS Series Sealed Combustion Oil Gun Furnace
24 Volts is supplied using an Optional Auxiliary
transformer. Red w/ Black stripe (24V Hot) and
Yellow w/ Black stripe (24V Com) wires are supplied
separately for optional accessories. The Red w/ Black
stripe and Yellow w/ Black stripe wires are marked
with an Accessory label.
M1S Series
24 Volts is supplied using the red (24V Hot) and Gray
(24V Com) wires in the 6-pin thermostat plug.
Electric Furnaces
For E1 and E2 Series interior furnace mounting order
NORDYNE P/N-902933, Alarm Mounting Bracket.
E1 & E2 Series - Standard Unit.
24 Volts is supplied using the Red (24V Hot) and Black
(24V Com) wires in the 6-pin thermostat plug.
Complete the installation by mounting the cover using the
supplied #6-32 x 1/4" machine screw. Attach the Black
switch knob provided with the alarm board. Ensure the
switch is set to the Audible Alarm “ON” position when
complete.
Field Supplied Air Conditioning and Heat Pump
Accessories
E1 & E2 Series with 2-Wire Relay Box.
24 Volts is supplied using the “Y” and “W” terminals on
the two wire relay box.
NOTE: This termination on the 2-wire relay box does
not follow standard low voltage connection practices.
E1EH & E2EH with 4 - 7 Wire Relay Box.
24 Volts is supplied using the “R” and “C” terminals on
the four wire relay box.
707510B (Replaces 707510A)
Specifications & illustrations subject to change without notice or incurring obligations (06/15).
O’Fallon, MO, © Nortek Global HVAC LLC 2015. All Rights Reserved.
INSTALLER: PLEASE LEAVE THESE
INSTALLATION INSTRUCTIONS WITH
THE HOMEOWNER
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Intertherm Vent Alarm System for Sloped Roof Kit Instrukcja instalacji

Typ
Instrukcja instalacji