6 3
TECHNICAL CHARACTERISTICS
Type SA91L SA91DL
Frequency range SAT IF 950-2400 MHz
Terr. TV 47-790 MHz
Gain SAT IF, adjustable 22 dB (0 ÷ -15 dB) by 1 dB step
Terr. TV, adjustable 22 dB (0 ÷ -15 dB) by 1 dB step
Slope SAT IF, switchable 0/3/5/7 dB
Terr. TV, switchable 0/6/12/18 dB
Isolation SAT/SAT 30 dB
SAT/Terr. TV 30 dB
Noise figure, typical ≤ 9 dB
Output level IMD3=60 dB Terr. TV**** 109 dBμV
Output level IMD3=35 dB SAT IF**** 114 dBμV
External equipment through V lines 14 V 0.5 A max. (switchable) -
powering through H lines 18 V 1.8 A* max. (switchable) -
through Terr line 12 V 0.1 A max. (switchable) -
DC pass through, switchable through H lines 2 A* max.
Supply voltage limit values, power consumption 198-250 V~ 50/60 Hz 7 W** DC 9-18 V 5 W***
Operating temperature range -20o ÷ + 50o C
Dimensions/Weight (packed) 335x135x52 mm/1.18 kg 255x135x32 mm/0.9 kg
* 1 A max. through one line
** without external DC loading; with maximal external DC load - 55 W
*** in line powering of SA91DL through H lines
**** measured using 2 equal signals; output level by DIN45004B - add 3 dB to mentioned above value
OPERATING
A multichannel amplier consists of highly isolated individual ampliers for every incoming line. Gain and slope controls of
each amplier are located between input and output connectors of corresponding line.
Gain regulation is performed by two step attenuators. The rst rough control attenuator has 4 possitions with 4 dB steps
and the second ne control attenuator has 4 possitions with 1 dB steps. The gain of amplier is dened by subtracting joint
attenuation of both attenuators from maximum gain.
Slope control has 4 positions. The value of each position determines the difference of gain at highest and lowest frequencies.
Amplier SA91L provides voltages 18 V to all horizontal polarization connectors, 14 V to all vertical polarization connectors
and 12 V to Terrestrial TV input connector. The switches on the output side allows disconnect voltages of 18 V and 14 V from
output connectors. This is usefull in large networks for prevention of interference between power supply units, when several of
them are incorporated. The switch on the input side allows disconnecting of voltage 12 V from from terrestrial TV input line to
avoid short-circuiting of power supply if terrestrial amlier with remote powering is not installed. All voltage sources have short
circuit protection with LED indicators. Green light indicates normal operation. The red light signals that short-circuit emerged in
corresponding line or power supply is overloaded (in the case of overloading 18 V red light will be intermittent). After that amplier
SA91L must unplugged from mains and network must be repaired. Allow at least 30 sec. before connecting to the mains again.
Amplier SA91DL is powered from central network power supply (for example SA91L) through horizontal polarization lines.
Both lines regarding DC are interconnected to minimize voltage loss in lines. It consumes up to 0.3 A from 18 V power supply.
Amplier has connector for auxilary power supply if voltage from central power supply is not accessible. If it is plugged voltage
is distributed to horizontal polarization lines in the same way as SA91L. In every case presence of voltage in lines will be
indicated by green LEDs near the corresponding switch. Voltage 12 V in the input connector of Terrestrial path will be only if
18 V is present in horizontal polarization lines.
Both ampliers SA91L and SA91DL has DC through path in every Satellite TV line. It provides exibility for installation of
power supply units inside the network.
WIDOK Z ZEWNĄTRZ
Wzmacniacz musi być zamocowany za pomocą stalowych śrub Ø 4-5 mm. Śruby nie są dołączone do opakowania.
SA91DL
SA91L
A H,Lo
A H,Lo
B H,Lo
B H,Lo
18V 18V14V 14V14V 14V18V 18V
A H,Hi
A H,Hi
B H,Hi
B H,Hi
A V,Lo
A V,Lo
B V,Lo
B V,Lo
A V,Hi
A V,Hi
B V,Hi
B V,Hi
Terr.TV
Terr.TV
Slope dB Slope dBSlope dB Slope dBSlope dB Slope dBSlope dB Slope dB Slope dB
Att. dB Att. dBAtt. dB Att. dBAtt. dB Att. dBAtt. dB Att. dBAtt. dB Att. dB
12 8 4 0 12 8 4 0
7 5 3 0 7 5 3 07 5 3 0 7 5 3 07 5 3 0 7 5 3 07 5 3 0 7 5 3 0 18 12 6 0
3 2 1 0 3 2 1 03 2 1 0 3 2 1 03 2 1 0 3 2 1 03 2 1 0 3 2 1 03 2 1 0 3 2 1 0
12 8 4 0 12 8 4 0 12 8 4 0 12 8 4 012 8 4 0 12 8 4 012 8 4 0 12 8 4 0
DC 12V Terr.TV in
OK
DC 18V
H,Lo/H,Hi out V,Lo/V,Hi out
DC 14V
OffOn OffOn
OffOn
OK OK
Overload
Regulacja
wzmocnienia
Korekcja ch-ki
tłumienia
przewodu
Zacisk
uziemienia
Wejścia
Wyjścia
12V przełącznik i wskaźnik
14V przełącznik
i wskaźnik
18V przełącznik
i wskaźnik
Frequency range SAT TV
Gain SAT TV
Frequency range Terr. TV
Gain Terr. TV
Power consumption from 18V
DC pass through H lines
V lines
5 W max
2 A max
0.5 A max
950-2400 MHz
22 dB
47-790 MHz
22 dB
SAT amplifier SA91DL
18V
AUX
1Amax
Wejście
18V DC
A H,Lo
A H,Lo
B H,Lo
B H,Lo
18V 18V14V 14V14V 14V18V 18V
A H,Hi
A H,Hi
B H,Hi
B H,Hi
A V,Lo
A V,Lo
B V,Lo
B V,Lo
A V,Hi
A V,Hi
B V,Hi
B V,Hi
Terr.TV
Terr.TV
Slope dB Slope dBSlope dB Slope dBSlope dB Slope dBSlope dB Slope dB Slope dB
Att. dB Att. dBAtt. dB Att. dBAtt. dB Att. dBAtt. dB Att. dBAtt. dB Att. dB
12 8 4 0 12 8 4 0
7 5 3 0 7 5 3 07 5 3 0 7 5 3 07 5 3 0 7 5 3 07 5 3 0 7 5 3 0 18 12 6 0
3 2 1 0 3 2 1 03 2 1 0 3 2 1 03 2 1 0 3 2 1 03 2 1 0 3 2 1 03 2 1 0 3 2 1 0
12 8 4 0 12 8 4 0 12 8 4 0 12 8 4 012 8 4 0 12 8 4 012 8 4 0 12 8 4 0
DC 12V Terr.TV in
OK
DC 18V
H,Lo/H,Hi out V,Lo/V,Hi out
DC 14V
OffOn OffOn
OffOn
OK OK
Overload
Overload
Overload
SAT amplifier SA91L
Frequency range SAT TV
Gain SAT TV
Frequency range Terr. TV
Gain Terr. TV
DC output current 18V 1.8A
14V 0.5A
12V 0.1A
950-2400 MHz
22 dB
47-790 MHz
22 dB
55 W max.
230 V
50 / 60Hz
Zacisk
uziemienia
Wejścia
Wejścia
12V przełącznik i wskaźnik
14V przełącznik
i wskaźnik
18V przełącznik
i wskaźnik
Regulacja
wzmocnienia
Korekcja ch-ki
tłumienia
przewodu