SICK WSE4F Instrukcja obsługi

Typ
Instrukcja obsługi
O P E R A T I N G I N S T R U C T I O N S
WSE4F
Miniature photoelectric sensors
O P E R A T I N G I N S T R U C T I O N S
WSE4F
Miniature photoelectric sensors
de
en
es
fr
it
ja
pl
pt
ru
zh
Described product
W4F
WSE4F
Manufacturer
SICK AG
Erwin-Sick-Str. 1
79183 Waldkirch
Germany
Legal information
This work is protected by copyright. Any rights derived from the copyright shall be
reserved for SICK AG. Reproduction of this document or parts of this document is
only permissible within the limits of the legal determination of Copyright Law. Any modi‐
fication, abridgment or translation of this document is prohibited without the express
written permission of SICK AG.
The trademarks stated in this document are the property of their respective owner.
© SICK AG. All rights reserved.
Original document
This document is an original document of SICK AG.
2006/42/EC
NO
SAFETY
8025304 / 2021-05-12 | SICK
Subject to change without notice
3
Contents
1 General safety notes......................................................................... 5
2 Notes on UL approval........................................................................ 5
3 Product description........................................................................... 5
3.1 Intended use............................................................................................. 5
3.2 Operating elements and status indicators.............................................. 5
4 Mounting............................................................................................. 6
5 Electrical installation........................................................................ 6
6 Additional functions.......................................................................... 8
7 Commissioning.................................................................................. 9
7.1 Alignment.................................................................................................. 9
7.2 Check the application conditions:........................................................... 10
7.3 Setting....................................................................................................... 11
7.4 Process data structure............................................................................. 12
8 Troubleshooting................................................................................. 12
9 Disassembly and disposal............................................................... 13
10 Maintenance...................................................................................... 13
11 Technical specifications................................................................... 14
11.1 Dimensional drawings.............................................................................. 15
CONTENTS
4
8025304 / 2021-05-12 | SICK
Subject to change without notice
1 General safety notes
Read the operating instructions before commissioning.
Connection, mounting, and configuration may only be performed by trained
specialists.
2006/42/EC
NO
SAFETY
Not a safety component in accordance with the EU Machinery Directive.
Do not install the sensor at locations that are exposed to direct UV radiation
(sunlight) or other weather influences, unless this is expressly permitted in the
operating instructions.
When commissioning, protect the device from moisture and contamination.
These operating instructions contain information required during the life cycle of
the sensor.
2 Notes on UL approval
The device shall be supplied from an isolating transformer having a secondary overcur‐
rent protective device that complies with UL 248 to be installed in the field rated either:
a) max 5 amps for voltages 0 ~ 20 V (0 ~ 28.3 V peak), or
b) 100 / Vp for voltages of 20 ~ 30 V (28.3 ~ 42.4 V peak).
Alternatively, they can be supplied from a Class 2 power supply.
UL Environmental Rating: Enclosure type 1
3 Product description
3.1 Intended use
The WSE4F is an opto-electronic through-beam photoelectric sensor (referred to as
“sensor” in the following) for the optical, non-contact detection of objects, animals, and
persons. A sender (WS) and a receiver (WE) are required for operation. If the product is
used for any other purpose or modified in any way, any warranty claim against SICK AG
shall become void.
3.2 Operating elements and status indicators
WSO4Fx-xxxxxxA0 WEO4Fx-xxxxxx30A00 WEO4Fx-xxxxxx00A00
4 3
1
2
4 3
1
4 3
GENERAL SAFETY NOTES 1
8025304 / 2021-05-12 | SICK
Subject to change without notice
5
1
BluePilot blue: alignment aid
2
Teach-Button: adjusting the sensitivity
3
LED indicator yellow: status of received light beam
4
LED indicator green: supply voltage active
4 Mounting
Mount sensors (sender and receiver) using suitable mounting brackets (see the SICK
range of accessories). Align the sender and receiver with each other.
NOTE
When mounting multiple through-beam photoelectric sensors next each other, swap
the arrangement of the sender (WSO4F) and receiver (WEO4F) for every second pair.
Also maintain a sufficiently large distance between the pairs based on the light spot
diameter of the sender (WSO4F). See figure 1 and figure 2.
Receiver (WE)
Receiver (WE)
Sender (WS)
Sender (WS)
Sender (WS)
Receiver (WE)
Figure 1: Arrangement of multiple through-beam photoelectric sensors
0
Distance in m (feet)
Dimensions in mm (inch)
100
(3.94)
200
(7.87)
–200
(–7.87)
–100
(–3.94)
0
2
(6.56)
6
(19.69)
8
(26.25)
4
(13.12)
10
(32.81)
10
(32.81)
1
(3.28)
Recommended sensing range for the best
performance
Figure 2: Light beam diameter
Note the sensor’s maximum permissible tightening torque of < 0,4 Nm.
5
Electrical installation
Operation in standard I/O mode:
4 MOUNTING
6
8025304 / 2021-05-12 | SICK
Subject to change without notice
The sensors must be connected in a voltage-free state. The following information must
be observed, depending on the connection type:
Male connector connection: Pin assignment
Cable: Wire color
Only apply voltage/switch on the voltage supply once all electrical connections have
been established.
Operation in IO-Link mode: Connect the device to a suitable IO-Link master and inte‐
grate in the master or control via IODD/function block. The green LED flashes on the
sensor. IODD and function block are available to download from www.sick.com under
the part number.
Explanations on connection diagram.
BN = brown
WH = white
BU = blue
BK = black
MF (pin 2 configuration) = external input, teach-in, switching signal
Q
L1
/C = switching output, IO-Link communication
Test = Test input
U
B
: 10 ... 30 V DC
Table 1: Electrical connection
WSE4Fx- x4 x2 xH x1 -xG
1 = BN
2 = WH
3 = BU
4 = BK
1
2
4 3
2
1
4
3
0.14 mm
2
AWG26
1
4
3
0.14 mm
2
AWG26
Table 2: DC
WSO4Fx- xx1ZZxZZZ xx2ZZxZZZ Xx3ZZxZZZ
1 = BN + (L+)
2 = WH -
3 = BU - (M)
4 = BK Test L+ Test M
Table 3: DC
WEO4Fx-
Push-pull xx162xxA
00
xx161xxA
00
xx163xxA
00
xx165xxA
00
xx16AxxA
00
xx16NxxA
00
xx16x
xxxA01-A99
PNP xx862xxA
00
xx861xxA
00
xx863xxA
00
xx865xxA
00
xx86AxxA
00
xx86NxxA
00
xx86xxxxA0
1-A99
1 = BN + (L+)
2 = WH MF
3 = BU - (M)
4 = BK Q
L1
/C
Default:
MF
Q
Q Alarm Alarm no func‐
tion
no func‐
tion
www.sick.co
m 8025304
Default:
Q
L1
/C
Q
Q Q
Q Q
Q
www.sick.co
m 8025304
ELECTRICAL INSTALLATION 5
8025304 / 2021-05-12 | SICK
Subject to change without notice
7
Table 4: DC
WSO4F- xx1ZZxZZZ xx2ZZxZZZ Xx3ZZxZZZ
1 = BN + (L+)
3 = BU - (M)
4 = BK Test L+ Test M
Table 5: DC
WEO4Fx- xx312x xx311x
1 = BN + (L+)
3 = BU - (M)
4 = BK Q
Q
Table 6: Push-pull, PNP, NPN
Push-pull
PNP
NPN
+ (L+)
Q ≤ 100 mA
‒ (M)
Push-pull
PNP
NPN
+ (L+)
Q ≤ 100 mA
‒ (M)
6 Additional functions
Alarm: Operation with borderline light reception
Alarm output: The sensor (WSE4F) features a pre-failure notification output (“Alarm”
in the connection diagram), which issues a notification if the sensor is only ready for
operation to a limited extent. The LED flashes in this case. Possible causes: Sensor
is contaminated, sensor is out of alignment. In the good state: LOW (0), if excessively
contaminated HIGH (1).
Health
Health output: The sensor (WSE4F) features a pre-failure notification output (“Health”
in the connection diagram), which issues a notification if the sensor is only ready for
operation to a limited extent or the cable has been interrupted. Possible causes: Sensor
6 ADDITIONAL FUNCTIONS
8
8025304 / 2021-05-12 | SICK
Subject to change without notice
is contaminated, sensor is out of alignment, cable is damaged. In the good state: HIGH
(1), if excessively contaminated or in the event of cable interruption LOW (0). The yellow
LED indicator flashes in this case.
Table 7: Alarm / Health
Alarm ( 100 mA) Health (100 mA)
+ (L+)
Alarm
‒ (M)
+ (L+)
Health
‒ (M)
+ (L+)
Alarm
‒ (M)
+ (L+)
Health
‒ (M)
Test input
Test input: The WSE4F sensors feature a test input (“Test” on the connection diagram
[see table 2, page 7]), which can be used to switch the sender off and, therefore, check
that the sensor is functioning correctly: If female cable connectors with LED indicators
are used, you must ensure that the TI is assigned accordingly.
It is important that there is no object between the sender and receiver, activate the test
input (see the connection diagram [see table 2, page 7]).
The send LED is shut down or the detection of an object is simulated. Refer to table 8
to check the function. If the switching output fails to behave in accordance with the
following table, check the application conditions, see "Troubleshooting", page 12.
Table 8: Test
Test M Test L+
+ (L+)
Test
‒ (M)
+ (L+)
Test
– (M)
+ (L+)
Test
‒ (M)
+ (L+)
Test
– (M)
7 Commissioning
7.1 Alignment
WSO4FP: Align the sender (WSO4F) with the receiver (WEO4F). Select the position so
that the red emitted light beam hits the receiver. Tip: Use white paper or a reflector as
an alignment aid. The sender must have a clear view of the receiver, with no object in
the path of the beam [see figure 3]. You must ensure that the optical openings (front
screen) of the sensors are completely clear.
ADDITIONAL FUNCTIONS 6
8025304 / 2021-05-12 | SICK
Subject to change without notice
9
WSO4FI: Align the sender (WSO4F) with the receiver (WEO4F). Select the position so
that the infrared light (not visible) hits the receiver. The correct alignment can only be
detected via the LEDs. See figure 3 and table 6. The sender must have a clear view of
the receiver, with no object in the path of the beam. You must ensure that the optical
openings (front screen) of the sensors are completely clear.
Figure 3: Alignment
WEO
WEO
WSO
Figure 4: Alignment aid BluePilot
7.2
Check the application conditions:
Sensing range
WSE4F are through-beam photoelectric sensors that can be used at shorter distances,
in particular due to the large sensing range or the very high operating reserve.
Observe the application conditions: Adjust the distance between the sender and the
receiver according to the corresponding diagram [see figure 6 and see figure 5,
page 11] (x = sensing range, y = operating reserve).
If several through-beam photoelectric sensors which are installed next to one another
are to be used, we recommend swapping the sender/receiver arrangement at every
second through-beam photoelectric sensor and ensuring that there is sufficient dis‐
tance between the through-beam photoelectric sensors. By doing this, mutual interfer‐
ence can be prevented [see figure 1].
Check the function as described in table 6. If the switching output fails to behave as
described in table 6, check the application conditions.
7 COMMISSIONING
10
8025304 / 2021-05-12 | SICK
Subject to change without notice
Standard reflectors:
0
Operating reserve
Distance in m (feet)
2
(6.56)
6
(19.69)
8
(26.25)
4
(13.12)
10
(32.81)
1
100
10
1,000
10,000
Figure 5: Characteristics
0
7.5 10
0
Distance in m (feet)
2
(6.56)
6
(19.69)
8
(26.25)
4
(13.12)
10
(32.81)
D
A
B
C
Figure 6: Bar graph
Light spot size:
0
Distance in m (feet)
Dimensions in mm (inch)
100
(3.94)
200
(7.87)
–200
(–7.87)
–100
(–3.94)
0
2
(6.56)
6
(19.69)
8
(26.25)
4
(13.12)
10
(32.81)
10
(32.81)
1
(3.28)
Figure 7: Light spot size
A Sensing range min. in m
B Sensing range max. in m
C Maximum distance range from receiver to sender
D Recommended distance range from receiver to sender
blue Recommended sensing range for the best performance
7.3 Setting
Sensitivity adjustment
WEO4Fx-xxxxxx30A00:
NOTE
For some applications (e.g., when switching errors arise due to reflections), we recom‐
mend slightly misaligning the sender and receiver or significantly reducing the oper‐
ating reserve. The WSE4F can suppress switching errors under these conditions by
means of a teach-in (via IO-Link or using the Teach-in pushbutton on the housing). This
reduces the operating reserve at the same time.
COMMISSIONING 7
8025304 / 2021-05-12 | SICK
Subject to change without notice
11
NOTE
Do not operate the teach-in button using sharp objects.
Please refer to the enclosed operating instructions for the IO-Link photoelectric sensor
for information about adjusting the IO-Link sensing range.
The sensor is adjusted and ready for operation.
WEO4Fx-xxxxxx00A00:
Sensor which it is not possible to set: the sensor is adjusted and ready for operation.
7.4 Process data structure
WSE4FP-xxxxxxxxAxx:
A00 A70 A71 A72 A73 A75
IO-Link V1.1
Process
data
2 bytes 4 bytes
Byte 0: bits 15... 8
Byte 1: bits 7... 0
Byte 0: bits 31...
24
Byte 1: bits 13...
16
Byte 2: bits 15...
8
Byte 3: bits 7... 0
Bit 0 / Data
type
Q
L1
/ Boolean
Bit 1 / Data
type
Q
L2
/ Boolean Qint.1 /
Boolean
Q
L2
/ Boo‐
lean
Qint.1 / Boolean
Bit... /
Descrip‐
tion / Data
type
2 ...15 /
[empty]
2 ...15 /
[time
measure‐
ment
value] /
UInt 14
2 … 15 /
[counter
value] /
UInt 14
2 … 15 /
[length /
speed
measure‐
ment] /
SInt14
2 /
Qint.1 /
Boolean
2 … 7 / [empty]
Bit... /
Descrip‐
tion / Data
type
3 … 15 /
[time
measure‐
ment
value] /
UInt13
8 … 31 / [carrier
load] / UInt 24
8 Troubleshooting
The Troubleshooting table indicates measures to be taken if the sensor stops working.
Table 9: Troubleshooting
LED indicator/fault pattern Cause Measures
WEO:
Green LED flashes
IO-Link communication None
Switching outputs do not
behave in accordance with
table 6
1. IO-Link communication
2. Change of the configuration
3. Short-circuit
1. None
2. Adjustment of the configura‐
tion
3. Check electrical connections
7 COMMISSIONING
12
8025304 / 2021-05-12 | SICK
Subject to change without notice
LED indicator/fault pattern Cause Measures
No object in beam path, no
output signal
Test input (Test) is not con‐
nected properly
Check connection of the test
input. When using female cable
connectors with LED indicators,
make sure the test input is
assigned correspondingly.
Yellow LED flashes Distance between sender
(WS) and receiver (WE) is
too large / Beam of WS is
not completely on WE or WE
is not aligned to WS / Front
screen and/or reflector is con‐
taminated.
Check sensing range / Clean‐
ing of the optical surfaces.
Yellow LED lights up, although
an object is in the path of the
beam.
The beam of light of a pho‐
toelectric through-beam sen‐
sor hits the receiver of
another (neighboring) photo‐
electric through-beam sensor
Swap the sender and receiver
arrangement at every sec‐
ond through-beam photoelec‐
tric sensor and ensure that
there is sufficient distance
between the through-beam
photoelectric sensors
9 Disassembly and disposal
The sensor must be disposed of according to the applicable country-specific regula‐
tions. Efforts should be made during the disposal process to recycle the constituent
materials (particularly precious metals).
NOTE
Disposal of batteries, electric and electronic devices
According to international directives, batteries, accumulators and electrical or
electronic devices must not be disposed of in general waste.
The owner is obliged by law to return this devices at the end of their life to the
respective public collection points.
WEEE: This symbol on the product, its package or in this document,
indicates that a product is subject to these regulations.
10 Maintenance
SICK sensors are maintenance-free.
We recommend doing the following regularly:
Clean the external lens surfaces
Check the screw connections and plug-in connections
No modifications may be made to devices.
Subject to change without notice. Specified product properties and technical data are
not written guarantees.
DISASSEMBLY AND DISPOSAL 9
8025304 / 2021-05-12 | SICK
Subject to change without notice
13
11 Technical specifications
WSE4F
Recommended sensing range for the best performance 0 m ... 7.5 m
Sensing range max. 0 m ... 10 m
Light spot diameter/distance Ø 55 mm (1,5 m) (Typ)
Supply voltage U
B
DC 10 ... 30 V
1)
Ripple ≤ 5 VSS
Output current I
max.
≤ 100 mA
Current consumption 25 mA
Communication mode COM2
IO-Link 1.1
Switching frequency 1000 Hz
2)
Max. response time ≤ 500 μs
3)
Enclosure rating IP66, IP67
Protection class III
4)
Circuit protection A, B, C, D
5)
Ambient operating temperature –40 °C ... +60 °C
1)
Limit values. U
B
connections reverse-polarity protected. Residual ripple max 5 V
PP
2)
With light / dark ratio 1:1
3)
Signal transit time with resistive load
4)
Reference voltage DC 50 V
5)
A = U
B
-connections reverse polarity protected
B = inputs and output reverse-polarity protected
C = Interference suppression
D = outputs overcurrent and short-circuit protected
11 TECHNICAL SPECIFICATIONS
14
8025304 / 2021-05-12 | SICK
Subject to change without notice
11.1 Dimensional drawings
1
4
2
3
16 (0.63) 12.1 (0.48)
9 (0.35)
5.6 (0.22)
8 (0.32)
8.1 (0.32)
3.5 (0.14) 16.6 (0.65)
37.2 (1.46)
4.7 (0.18)
3.5 (0.14)
Figure 8: Dimensional drawing 1, cable
1
Center of optical axis
2
M3 threaded mounting hole
3
Connection
4
Operating and status indicators
1
4
2
3
16 (0.63) 12.1 (0.48)
9 (0.35)
5.6 (0.22)
8 (0.32)
8.1 (0.32)
3.5 (0.14) 16.6 (0.65)
37.2 (1.46)
4.7 (0.18)
3.5 (0.14)
5
77 (3.03)
33 (1.3)
M8
Figure 9: Dimensional drawing 2, cable
with male connector
1
4
2
3
16 (0.63) 12.1 (0.48)
9 (0.35)
M8
(0.31)
5.6 (0.22)
8 (0.32)
11 (0.43)
3.5 (0.14) 16.6 (0.65)
40.1 (1.58)
7.6 (0.3)
3.5 (0.14)
Figure 10: Dimensional drawing 3, Male
connector, M8
TECHNICAL SPECIFICATIONS 11
8025304 / 2021-05-12 | SICK
Subject to change without notice
15
B E T R I E B S A N L E I T U N G
WSE4F
Miniatur-Lichtschranken
de
en
es
fr
it
ja
pl
pt
ru
zh
Beschriebenes Produkt
W4F
WSE4F
Hersteller
SICK AG
Erwin-Sick-Str. 1
79183 Waldkirch
Deutschland
Rechtliche Hinweise
Dieses Werk ist urheberrechtlich geschützt. Die dadurch begründeten Rechte bleiben
bei der Firma SICK AG. Die Vervielfältigung des Werks oder von Teilen dieses Werks
ist nur in den Grenzen der gesetzlichen Bestimmungen des Urheberrechtsgesetzes
zulässig. Jede Änderung, Kürzung oder Übersetzung des Werks ohne ausdrückliche
schriftliche Zustimmung der Firma SICK AG ist untersagt.
Die in diesem Dokument genannten Marken sind Eigentum ihrer jeweiligen Inhaber.
© SICK AG. Alle Rechte vorbehalten.
Originaldokument
Dieses Dokument ist ein Originaldokument der SICK AG.
2006/42/EC
NO
SAFETY
8025304 / 2021-05-12 | SICK
Subject to change without notice
17
Inhalt
12 Allgemeine Sicherheitshinweise..................................................... 19
13 Hinweise zur UL Zulassung.............................................................. 19
14 Produktbeschreibung....................................................................... 19
14.1 Bestimmungsgemäße Verwendung......................................................... 19
14.2 Bedien- und Anzeigeelemente................................................................. 19
15 Montage.............................................................................................. 20
16 Elektrische Installation..................................................................... 21
17 Zusatzfunktionen.............................................................................. 23
18 Inbetriebnahme................................................................................. 24
18.1 Ausrichtung............................................................................................... 24
18.2 Die Einsatzbedingungen prüfen:.............................................................. 25
18.3 Einstellung................................................................................................. 26
18.4 Prozessdatenstruktur............................................................................... 27
19 Störungsbehebung............................................................................ 27
20 Demontage und Entsorgung............................................................ 28
21 Wartung.............................................................................................. 28
22 Technische Daten.............................................................................. 29
22.1 Maßzeichnungen...................................................................................... 30
INHALT
18
8025304 / 2021-05-12 | SICK
Subject to change without notice
12 Allgemeine Sicherheitshinweise
Lesen Sie vor der Inbetriebnahme des Geräts die Betriebsanleitung.
Der Anschluss, die Montage und die Konfiguration des Geräts dürfen nur
von geschultem Fachpersonal vorgenommen werden.
2006/42/EC
NO
SAFETY
Bei diesem Gerät handelt es sich um kein sicherheitsgerichtetes Bauteil im
Sinne der EU-Maschinenrichtlinie.
Installieren Sie den Sensor nicht an Orten, die direkter UV-Strahlung (Son‐
nenlicht) oder sonstigen Wettereinflüssen ausgesetzt sind, ausser dies ist in der
Betriebsanleitung ausdrücklich erlaubt.
Bei der Inbetriebnahme ist das Gerät ausreichend vor Feuchtigkeit und Verschmut‐
zung zu schützen.
Die vorliegende Betriebsanleitung enthält Informationen, die während des Lebens‐
zyklus der Lichtschranke benötigt werden.
13 Hinweise zur UL Zulassung
The device shall be supplied from an isolating transformer having a secondary overcur‐
rent protective device that complies with UL 248 to be installed in the field rated either:
a) max 5 amps for voltages 0 ~ 20 V (0 ~ 28.3 V peak), or
b) 100 / Vp for voltages of 20 ~ 30 V (28.3 ~ 42.4 V peak).
Alternatively, they can be supplied from a Class 2 power supply.
UL Environmental Rating: Enclosure type 1
14 Produktbeschreibung
14.1 Bestimmungsgemäße Verwendung
Die WSE4F ist eine opto-elektronische Einweg-Lichtschranke (im Folgenden Sensor
genannt) und wird zum optischen, berührungslosen Erfassen von Sachen, Tieren und
Personen eingesetzt. Zum Betrieb ist ein Sender (WS) und ein Empfänger (WE) erfor‐
derlich. Bei jeder anderen Verwendung und bei Veränderungen am Produkt verfällt
jeglicher Gewährleistungsanspruch gegenüber der SICK AG.
14.2 Bedien- und Anzeigeelemente
ALLGEMEINE SICHERHEITSHINWEISE 12
8025304 / 2021-05-12 | SICK
Subject to change without notice
19
WSO4Fx-xxxxxxA0 WEO4Fx-xxxxxx30A00 WEO4Fx-xxxxxx00A00
4 3
1
2
4 3
1
4 3
1
BluePilot blau: Ausrichthilfe
2
Teach-Taste: Einstellung der Empfindlichkeit
3
Anzeige-LED gelb: Status Lichtempfang
4
Anzeige-LED grün: Betriebsspannung aktiv
15 Montage
Sensoren (Sender und Empfänger) an geeignete Befestigungswinkel montieren (siehe
SICK-Zubehör-Programm). Sender und Empfänger zueinander ausrichten.
14 PRODUKTBESCHREIBUNG
20
8025304 / 2021-05-12 | SICK
Subject to change without notice
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147

SICK WSE4F Instrukcja obsługi

Typ
Instrukcja obsługi