Important Safety Instructions: Read Before Installation
INSTALLATION & MAINTENANCE GUIDE
!
www.amplighting.com
–2–
This luminaire is intended for installation in accordance with local codes
and the National Electric Code (NEC). Failure to adhere to these codes and
instructions may result in serious injury, property damage and void the
warranty.
These instructions do not intend to cover all variations in installation,
operation maintenance or mounting situations.
1. Make sure the power is turned OFF before installing or servicing this
luminaire.
2. WARNING: risk of electrical shock. Install all luminaires 10 feet (3.05M)
or more from pool, spa or fountain.
3. This luminaire is intended to be used only with a power supply
(transformer) rated maximum of 300 watts (25 AMPS) at 15 volts.
4. Wiring connections must be made with UL listed wire connectors that are
suitable for outdoor use.
5. Position the low voltage wire and wire connector so that it is located
within 6 inches (15.2 cm) from a building structure, a luminaire or
tting.
6. The main low voltage cable is intended for shallow burial - less than 6
inches (152 mm).
7. If additional lengths of low voltage cable are required, please contact
www.amplighting.com or call 1-813-978-3900.
Important Safety Instructions
!
INSTRUCTIONS PERTAINING TO A RISK OF FIRE, OR INJURY TO PERSONS
Lighted lamp is HOT!
WARNING – To reduce the risk of FIRE OR INJURY TO PERSONS.
1. Turn off/unplug and allow to cool before replacing lamp.
2. Lamp gets HOT quickly! Contact only switch/plug when turning on.
3. Do not touch the hot lens, guard or enclosure.
4. Keep lamp away from materials that may burn.
5. Do not touch lamp at any time. Use a soft cloth. Oil from skin may dam-
age lamp.
6. Do not operate the luminaire tting with a missing or damaged shield.
SAVE THESE INSTRUCTIONS
[email protected] • 813.978.3900
Product Dimensions
–3–
Package Contents
Remove Lens
1
A. (1) Wall Mount
B. (2) Mounting Screws
A. (2) Wall Anchors
B. (1) Luminaire
3.5”
2.54”
7”
2.5”
4.25”
Twist the top and bottom lens to remove
them from the luminaire.
Lens
Lens
Luminaire
INSTALLATION & MAINTENANCE GUIDE
–4–
www.amplighting.com
–4–
Remove Luminaire from Wall Mount
3
Install Bulb and Lens
2
AMP
®
LateralPro Up/Down Sconce
AHS-7003-4-B-BZ
Insert the bulbs (sold separately) with
the correct wattage and type marked on
the luminaire label.
CAUTION: Do not exceed maximum
wattage marked on luminaire label.
NOTE: DO NOT touch bulb with bare
hands. Use soft cloth to handle bulb.
Tighten the lenses back onto the xture
body.
Bulb
Socket
Bulb
Lens
Luminaire
Body
Lens
Remove the mounting screws off the
top and bottom of the luminaire and
remove the luminaire from the wall
mount.
Wall
Mount
Mounting Screw
Luminaire
[email protected] • 813.978.3900
–5–
Install Wall Mount
4
Wire Connection
5
Place the wall mount at the desired
location and mark two points on the
wall surface for the wall anchors.
Remove the wall mount and drill the
proper holes on the wall.
Insert the wall anchors, into the drilled
holes. Pass the main low voltage supply
cable through the center hole on the
wall mount and attach it onto the wall.
Secure with the lock screws. Hand
tighten until snug.
Wall Anchor
Wall Mount
Main Low Voltage
Supply Cable
Lock Screw
Using two wire connectors (sold
separately) connect the supply
wires from the xture to the main
low voltage supply cable leads.
Wire Connectors
Supply Wires from
Luminaire
Main Low
Voltage Supply
Cable
INSTALLATION & MAINTENANCE GUIDE
–6–
www.amplighting.com
–6–
AMP
®
LateralPro Up/Down Sconce
AHS-7003-4-B-BZ
Install/Replace Bi-Pin
6
Carefully tuck all the wires into
the wall mount. Attach the back
of the luminaire over the wall
mount. Secure it by threading the
mounting screws onto the top and
bottom of the luminaire body.
Mounting Screw
Wall
Mount
Maintenance – Install/Replace Bulb
Remove the lens assembly off the luminaire body to expose the bulb and
replace it with the correct wattage and type marked on the luminaire label.
Reinstall the lens assembly.
IMPORTANT: Halogen bulbs must be protected from moisture and dust at all
times. Always reinstall the shade and lens when removed.
–6––6–
[email protected] • 813.978.3900
–7–
IS-AHS-7003-4-B-BZ.ver1
Specications and product details subject to change without notice.
© Copyright 2019, AMP
®
Lighting, Lutz FL USA 33549 • All rights reserved.
[email protected] • 813.978.3900
Help Hotline:
1-813-978-3900 • Mon-Fri 9am-6pm (EST)
www.amplighting.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

AMP Lighting AHS-7003-4-B-BZ Instrukcja instalacji

Typ
Instrukcja instalacji
Ten podręcznik jest również odpowiedni dla