AMP Lighting AAL-1024-0-B-BZ Installation & Maintenance Manual

Typ
Installation & Maintenance Manual
INSTALLATION & MAINTENANCE GUIDE
Help Hotline:
1-813-978-3900 • Mon-Fri 9am-6pm (EST)
www.amplighting.com
AMP
®
Low Voltage Landscape Lighting
AMP
®
Stem with Integrated Hub
AAL-1024-0-B-BZ
AMP
®
Stem with Integrated Hub Top
ASM-2408-0-B-BZ
INSTALLATION & MAINTENANCE GUIDE
www.amplighting.com
–2–
Important Safety Instructions: Read Before Installation
!
This luminaire is intended for installation in accordance with local codes
and the National Electric Code (NEC). Failure to adhere to these codes and
instructions may result in serious injury, property damage and void the
warranty.
These instructions do not intend to cover all variations in installation,
operation maintenance or mounting situations.
1. Make sure the power is turned OFF before installing or servicing this
luminaire.
2. WARNING: risk of electrical shock. Install all luminaires 10 feet (3.05M)
or more from pool, spa or fountain.
3. This luminaire is intended to be used only with a power supply
(transformer) rated maximum of 300 watts (25 AMPS) at 15 volts.
4. Wiring connections must be made with UL listed wire connectors that are
suitable for outdoor use.
5. Position the low voltage wire and wire connector so that it is located
within 6 inches (15.2 cm) from a building structure, a luminaire or
tting.
6. The main low voltage cable is intended for shallow burial - less than 6
inches (152 mm).
Important Safety Instructions
!
INSTRUCTIONS PERTAINING TO A RISK OF FIRE, OR INJURY TO PERSONS
Lighted lamp is HOT!
WARNING – To reduce the risk of FIRE OR INJURY TO PERSONS.
1. Turn off/unplug and allow to cool before replacing lamp.
2. Lamp gets HOT quickly! Contact only switch/plug when turning on.
3. Do not touch the hot lens, guard or enclosure.
4. Keep lamp away from materials that may burn.
5. Do not touch lamp at any time. Use a soft cloth. Oil from skin may
damage lamp.
6. Do not operate the luminaire tting with a missing or damaged shield.
SAVE THESE INSTRUCTIONS
[email protected] • 813.978.3900
Product Dimensions
–3–
Package Contents
A. (1) Fixture Body
B. (1) Integrated Hub Top
1”
4”
22”
2.83”
There are two types of mounts that are sold separately for this xture, the
Stake Mount and Surface Mount.
INSTALLATION & MAINTENANCE GUIDE
–4–
www.amplighting.com
–4–
2
1
AMP
®
Stem with Integrated Hub Top
ASM-2408-0-B-BZ
Wire Connection
Install Stake
Option 1: Stake Mount
Insert the main supply wire continuation (if needed) and the main
supply wire up through the bottom of the stake mount and strip the
ends of both sets of supply wires.
Attach the xture wires and both sets of the main supply wires to their
correct connectors in the integrated hub top.
Once the wires are installed properly, thread the integrated hub top
back onto the stake mount and hand tighten until snug.
Integrated Hub Top
Main Supply Wires
Fixture Wires
Connectors
Stake Mount
Main Supply Wire
Main Supply Wire
Continuation
Determine the desired location
for mounting the stake mount.
Hammer the stake into the
ground until ange of stake is
ush to grade. To avoid damage
to the stake, place a board
on top of the stake while
hammering.
Note: If the ground is hard and
the stake is difcult to install,
make a crosscut in the ground
using a at shovel.
Board
Ground
Soil
Stake
[email protected] • 813.978.3900
–5–
INSTALLATION & MAINTENANCE GUIDE
3
AMP
®
Stem with Integrated Hub Top
ASM-2408-0-B-BZ
Install Stake Mount
Clear away an area in the
ground at the wireway slot on
top of the stake. Lay the supply
wires into the wireway slot and
screw the stake mount on to
the stake. Tighten until snug.
Stake Mount
Ground
Supply Wires
Wireway Slot
Soil
Stake
INSTALLATION & MAINTENANCE GUIDE
–6–
www.amplighting.com
–6–
1
AMP
®
Stem with Integrated Hub Top
ASM-2408-0-B-BZ
Wire Connection
Option 2: Surface Mount
Insert the main supply wire continuation (if needed) and the main
supply wire up through the bottom of the surface mount and strip the
ends of both sets of supply wires.
Attach the xture wires and both sets of the main supply wires to their
correct connectors in the integrated hub top.
Once the wires are installed properly, thread the integrated hub top
back onto the surface mount and hand tighten until snug.
Integrated Hub Top
Main Supply Wires
Fixture Wires
Connectors
Surface Mount
Main Supply Wire
Main Supply Wire
Continuation
2
Install Surface Mount
Place the surface mount onto
the desired location and secure
it with the screws. Tighten with
a screwdriver.
Screw
Optional Anchor
Surface Mount
Washer
–6––6–
[email protected] • 813.978.3900
–7–
INSTALLATION & MAINTENANCE GUIDE
AMP
®
Stem with Integrated Hub Top
ASM-2408-0-B-BZ
Bulb Installation
1
Remove Stem Top
Twist the stem top counter- clock-
wise and remove it from the stem.
Stem Top
Stem
2
Install Bulb
Insert the bulb with the correct watt-
age and type marked on the xture
label and push rmly into place.
CAUTION: Do not exceed
maximum wattage marked on
luminaire label.
Socket
Bulb
INSTALLATION & MAINTENANCE GUIDE
AMP
®
Stem with Integrated Hub Top
ASM-2408-0-B-BZ
www.amplighting.com
–8–
3
Install Stem Top to Stem
Place the stem top over the
bulb and twist it clockwise
onto the stem.
Stem Top
Stem
4
Install Cast Brass Hat to Stem (Option A)
Thread the hat of your choice
onto the stem top. Hand tighten
until snug.
Note: For Cast Brass AMP
®
hats
you will not need a nial to install
the hat. You will screw the hat
directly to the top of the stem.
Stem Top
Hat of your choice
INSTALLATION & MAINTENANCE GUIDE
AMP
®
Stem with Integrated Hub Top
ASM-2408-0-B-BZ
[email protected] • 813.978.3900
–9–
5
Install Spun Brass Hat to Stem (Option B)
Place the hat of your choice onto
the stem top and secure it with
the nial. Hand tighten until snug.
Shield
Finial
Hat of your choice
INSTALLATION & MAINTENANCE GUIDE
AMP
®
Stem with Integrated Hub Top
ASM-2408-0-B-BZ
www.amplighting.com
–10–
Install/Replace Bulb
Remove the hat and stem top to expose the bulb and replace it
with the correct wattage and type marked on the xture label. Then,
reinstall the stem top and hat.
IMPORTANT: Bulbs must be protected from moisture and dust at all
times. Always reinstall the stem top and hat when removed.
INSTALLATION & MAINTENANCE GUIDE
AMP
®
Stem with Integrated Hub Top
ASM-2408-0-B-BZ
[email protected] • 813.978.3900
–11–
IS-ASM-2408-0-BBZ-ver1.pdf
Specications and product details subject to change without notice.
© Copyright 2019, AMP
®
Lighting, Lutz FL USA 33549 • All rights reserved.
[email protected] • 813.978.3900
Help Hotline:
1-813-978-3900 • Mon-Fri 9am-6pm (EST)
www.amplighting.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

AMP Lighting AAL-1024-0-B-BZ Installation & Maintenance Manual

Typ
Installation & Maintenance Manual

w innych językach