AMP Lighting PinnaclePro AAL-1016-40-B-BZ Instrukcja instalacji

Typ
Instrukcja instalacji

Ten podręcznik jest również odpowiedni dla

INSTALLATION & MAINTENANCE GUIDE
Help Hotline:
1-813-978-3900 • Mon-Fri 9am-6pm (EST)
www.amplighting.com
AMP
®
Low Voltage Landscape Lighting
AMP
®
PinnaclePro Downlight
AAL-1016-40-B-BZ
AMP
®
PinnaclePro Downlight
AAL-1016-40-B-BZ
INSTALLATION & MAINTENANCE GUIDE
www.amplighting.com
–2–
Important Safety Instructions: Read Before Installation
!
This luminaire is intended for installation in accordance with local codes
and the National Electric Code (NEC). Failure to adhere to these codes and
instructions may result in serious injury, property damage and void the
warranty.
These instructions do not intend to cover all variations in installation,
operation maintenance or mounting situations.
1. Make sure the power is turned OFF before installing or servicing this
luminaire.
2. WARNING: risk of electrical shock. Install all luminaires 10 feet (3.05M)
or more from pool, spa or fountain.
3. This luminaire is intended to be used only with a power supply
(transformer) rated maximum of 300 watts (25 AMPS) at 15 volts.
4. Wiring connections must be made with UL listed wire connectors that are
suitable for outdoor use.
5. Position the low voltage wire and wire connector so that it is located
within 6 inches (15.2 cm) from a building structure, a luminaire or
tting.
6. The main low voltage cable is intended for shallow burial - less than 6
inches (152 mm).
7. If additional lengths of low voltage cable are required, please contact
www.amplighting.com or call 1-813-978-3900.
Important Safety Instructions
!
INSTRUCTIONS PERTAINING TO A RISK OF FIRE, OR INJURY TO PERSONS
Lighted lamp is HOT!
WARNING – To reduce the risk of FIRE OR INJURY TO PERSONS.
1. Turn off/unplug and allow to cool before replacing lamp.
2. Lamp gets HOT quickly! Contact only switch/plug when turning on.
3. Do not touch the hot lens, guard or enclosure.
4. Keep lamp away from materials that may burn.
5. Do not touch lamp at any time. Use a soft cloth. Oil from skin may
damage lamp.
6. Do not operate the luminaire tting with a missing or damaged shield.
SAVE THESE INSTRUCTIONS
[email protected] • 813.978.3900
Product Dimensions
–3–
Package Contents
A. (1) Fixture Body
B. (1) Glare Guard
C. (1) Allen Key
3.25”
5”
6.25”
7.63”
2.5”
INSTALLATION & MAINTENANCE GUIDE
–4–
www.amplighting.com
–4–
2
1
AMP
®
PinnaclePro Downlight
AAL-1016-40-B-BZ
Install Fixture to Base
Install Base
Place the supply wire through the base and thread the base onto the
xture body. Make sure the gap on the base and the xture body are
in the same direction. Tighten the lock nut against the base.
Fixture Body
Lock Nut
Supply Wire
Base
Gap
Pull the supply wire through
the gap on the base. Attach the
base onto the tree by securing
with the screws. Tighten with a
screwdriver.
Tree
Base
Screw
[email protected] • 813.978.3900
–5–
INSTALLATION & MAINTENANCE GUIDE
3
4
AMP
®
PinnaclePro Downlight
AAL-1016-40-B-BZ
Wire Connection
Remove Glare Guard
Strip both leads from the luminaire
pigtail. Using two wire connectors (sold
separately), connect the leads from the
luminaire to the main supply cable leads.
Main Supply Cable
Wire Connectors
Fixture
Pigtail
Loosen the set screw and remove
the glare guard from the xture
body.
REMOVE
Fixture Body
Set Screw
Glare Guard
5
Remove Lens
Rotate the lens to remove it
from the xture body.
Fixture Body
Lens
INSTALLATION & MAINTENANCE GUIDE
–6–
www.amplighting.com
–6–
6
AMP
®
PinnaclePro Downlight
AAL-1016-40-B-BZ
Install MR16 Bulb
Insert the MR16 bulb with the
correct wattage and type marked
on the xture label and secure
into place.
CAUTION: Do not exceed
maximum wattage marked on
luminaire label.
MR16 Bulb
Socket
7
Install Lens
Place the lens back onto the
xture body and rotate it until it
is secured properly.
Fixture Body
Lens
–6––6–
[email protected] • 813.978.3900
–7–
Install/Replace Bulb
8
Install Glare Guard
Install the glare guard back onto
the xture body and secure with
previously removed set screw.
Hand tighten until snug.
Fixture Body
Set Screw
Glare Guard
8
Install Glare Guard
By using an Allen wrench, loosen
the set screw on the knuckle
and adjust the xture body to
the desired direction. Once the
desired direction is achieved,
tighten the set screw to secure.
ROTAT E
Fixture Body
Allen Wrench
Set Screw
Remove the glare guard and the lens to expose the MR16 bulb and replace it
with the correct wattage and type marked on the xture label. Then,
reinstall the lens and the glare guard.
IMPORTANT: MR16 bulb must be protected from moisture and dust at all
times. Always reinstall the lens and the glare guard when removed.
IS-AAL-1016-40-B-BZ-ver1.pdf
Specications and product details subject to change without notice.
© Copyright 2019, AMP
®
Lighting, Lutz FL USA 33549 • All rights reserved.
[email protected] • 813.978.3900
Help Hotline:
1-813-978-3900 • Mon-Fri 9am-6pm (EST)
www.amplighting.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

AMP Lighting PinnaclePro AAL-1016-40-B-BZ Instrukcja instalacji

Typ
Instrukcja instalacji
Ten podręcznik jest również odpowiedni dla