AMP Lighting AAL-1018 Instrukcja instalacji

Typ
Instrukcja instalacji

Ten podręcznik jest również odpowiedni dla

INSTALLATION & MAINTENANCE GUIDE
Help Hotline:
1-813-978-3900 • Mon-Fri 9am-6pm (EST)
www.amplighting.com
AMP
®
Low Voltage Landscape Lighting
AMP
®
PinnaclePro Mini
AAL-1018-4-X-XX
AMP
®
PinnaclePro Spotlight
AAL-1018-4-X-XX
INSTALLATION & MAINTENANCE GUIDE
www.amplighting.com
–2–
[email protected] • 813.978.3900
Product Dimensions
–3–
1
Important Safety Instructions: Read Before Installation
!
This luminaire is intended for installation in accordance with local codes
and the National Electric Code (NEC). Failure to adhere to these codes and
instructions may result in serious injury, property damage and void the
warranty.
These instructions do not intend to cover all variations in installation,
operation maintenance or mounting situations.
1. Make sure the power is turned OFF before installing or servicing this
luminaire.
2. WARNING: risk of electrical shock. Install all luminaires 10 feet (3.05M)
or more from pool, spa or fountain.
3. This luminaire is intended to be used only with a power supply
(transformer) rated maximum of 300 watts (25 AMPS) at 15 volts.
4. Wiring connections must be made with wire connectors that are suitable
for outdoor use.
5. Position the low voltage wire and wire connector so that it is located
within 6 inches (15.2 cm) from a building structure, a luminaire or
tting.
6. The main low voltage cable is intended for shallow burial - less than 6
inches (152 mm).
7. If additional lengths of low voltage cable are required, please contact
www.amplighting.com or call 1-813-978-3900.
Important Safety Instructions
!
INSTRUCTIONS PERTAINING TO A RISK OF FIRE, OR INJURY TO PERSONS
Lighted lamp is HOT!
WARNING – To reduce the risk of FIRE OR INJURY TO PERSONS.
1. Turn off/unplug and allow to cool before replacing lamp.
2. Lamp gets HOT quickly! Contact only switch/plug when turning on.
3. Do not touch the hot lens, guard or enclosure.
4. Keep lamp away from materials that may burn.
5. Do not touch lamp at any time. Use a soft cloth. Oil from skin may
damage lamp.
6. Do not operate the luminaire tting with a missing or damaged shield.
SAVE THESE INSTRUCTIONS
Package Contents
A. (1) Fixture
B. (1) Stake
2.75”
4.5”
2.75”
1.75”
Remove Glare Guard and Shield from Fixture
Unlock the set screw and remove the
glare guard from the shield. Loosen the
shield and remove it from the xture.
Glare Guard
Set
Screw
Shield
Fixture
INSTALLATION & MAINTENANCE GUIDE
–4–
www.amplighting.com
–4–
3
2
[email protected] • 813.978.3900
–5–
INSTALLATION & MAINTENANCE GUIDE
4
5
AMP
®
PinnaclePro Spotlight
AAL-1018-4-X-XX
AMP
®
PinnaclePro Spotlight
AAL-1018-4-X-XX
Install MR11 Lamp
Insert the lamp with the correct
wattage and type marked on the
xture label.
CAUTION: Do not exceed maximum
wattage marked on luminaire label.
NOTE: DO NOT touch lamp with bare
hands. Use soft cloth to handle lamp.
Socket
MR11 Lamp
(sold
separately)
Install Glare Guard and Shield to Fixture
Attach the shield back onto the
xture. Place the glare guard over the
shield and secure with the set screw.
Tighten until snug.
Glare Guard
Set
Screw
Shield
Fixture
Install Stake
Board
Stake
Soil
Ground
Determine the desired location for
mounting the xture. Hammer the stake
into the ground until ange of stake is ush
to grade. To avoid damage to the stake,
place a board on top of the stake while
hammering.
NOTE: If the ground is hard and the stake
is difcult to install, make a crosscut in the
ground using a at shovel.
Install Fixture to Stake
Clear away an area in the ground at
the wireway slot on top of the stake.
Lay the luminaire pigtail into the
wireway slot and screw the xture
onto the stake. Tighten until snug.
Fixture
Pigtail
Wireway Slot
Stake
INSTALLATION & MAINTENANCE GUIDE
–6–
www.amplighting.com
–6–
[email protected] • 813.978.3900
–7–
6
Install/Replace Bulb
AMP
®
PinnaclePro Spotlight
AAL-1018-4-X-XX
Wire Connections
Strip both leads from the luminaire pigtail. Using two wire connectors (sold
separately), connect the leads from the luminaire to the main supply cable
leads.
Pigtail
Main Supply Cable
Wire Connectors
Remove the glare guard and the shield to expose the lamp and replace
it with the correct wattage and type marked on the xture label. Then
reinstall the shield and the glare guard to the xture.
IMPORTANT: Halogen lamps must be protected from moisture and dust at all
times. Always reinstall the shield when moved.
IS-AAL-1018-4-X-XX-ver1.pdf
Specications and product details subject to change without notice.
© Copyright 2019, AMP
®
Lighting, Lutz FL USA 33549 • All rights reserved.
[email protected] • 813.978.3900
Help Hotline:
1-813-978-3900 • Mon-Fri 9am-6pm (EST)
www.amplighting.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

AMP Lighting AAL-1018 Instrukcja instalacji

Typ
Instrukcja instalacji
Ten podręcznik jest również odpowiedni dla

w innych językach