jbc TESE-QA Precision Hot Air Station extractor desk Instrukcja obsługi

Typ
Instrukcja obsługi
Precision Hot Air Station
without extractor desk
Ref. TESE-QA
INSTRUCTION MANUAL
Manual ............................1 unit
Ref. 0019044
Power cable ...................1 unit
Ref. 0009417 (100V / 120V)
0009401 (230V)
Precision Hot Air Station
without extractor desk
Ref. TESE-QA
Thermocouple type K ..................................1 unit
Ref. PH218
Packing List
The following items are included:
Nozzles ........................................................... 3 units
Ref. TN9209 Ø 3mm (0.12 in)
TN9208 Ø 4mm (0.16 in)
TN9080 Ø 5mm (0.20 in)
Heater hose set .............1 unit
Ref. TE-TB (100V / 120V / 230V)
Stand ................................1 unit
Ref. TE-SE
TESE Control Unit .........1 unit
Ref. TESE-1A (100V / 120V)
TESE-2A (230V)
INSTRUCTION MANUAL
Kapton Tape ................ 1 unit
Ref. PH217
2
www.jbctools.com
Hot Air button
(On / Off)
Power Socket
Fuse
USB connector
Robot RS232
connector
P-005 Pedal connector
Equipotential
connector
Auxiliar
connector
Heating element
Heater Hose set
Ref. TE-TB
Stand
Ref. TE-SE
Suction Tube
Ref. 0932330
For tripods and extractors
Thermocouple type K
Activates de suction pump
USB-A connector
Features
Main Switch
www.jbctools.com
3
17:14
20ºC
Power
45% 120ºC Selected
TC
Temp.
4m 38s
400ºC 80%
400ºC Selected
Protection
Hot Air Temp. Air Flow Selec.
Menu Options
Station
Information
Current
Air
Temp.
Selected
Air
Temp.
Instant Power
Supplied to
Heater
Status
Indicator
Selected
Air Flow
Selected
External TC
Temp.
JT / TE Work Screen
Status Bar
The JT/TE offers an intuitive user interface which provides quick access to station parameters.
Default PIN: 0105
Current
External
TC Temp.
Station Tools Counters
ResetLanguage
Set the station
parameters
Set the tool
parameters
Display the hours
worked in each cycle
It is possible to
choose the language
from a list.
Allows you to carry
out an overall station
reset restoring all the
parameters to their
default values.
Station troubleshooting available on the product page at www.jbctools.com
Troubleshooting
4
Point
2/5
Temp
250
ºC
Flow
60
%
Time
2m 30s
3m 18s
Hot Air Temp
240
ºC ºC %
Ext. TC Temp
20
Air Flow
80
3m 18s
· Add point
· Delete point
· Load profile
· Save profile
· Exit
Current
Air
Temp.
Data for
These Points
Profile
Name
Current
Air flow
Current
External
TC Temp.
In this mode you can set up or edit as many as 25 profiles of temperature and air flow.
Edit Mode
Menu
Options
Profiles
Advanced functionalities
To work with profiles it is essential to use the RWB / RWS / RWT rework arms. The
Rework Arms supports the Hot Air Heater maintaining the distance and position to
the component.
www.jbctools.com
5
450
400
350
300
250
150
100
50
200
Power Temp
17:14
JBC Net
USB fl ash drive is connected.
Station is controlled by a PC.
Station is controlled by a robot.
System Notifications
Station software update.
Press INFO to start the process.
Warning.
Press INFO for failure description.
Error.
Press INFO for failure description,
the type of error and how to proceed.
The following icons will be displayed on the screen’s status bar.
JT-A
TC
Suction
OK
17:14
20
ºC
Power
45%
120ºC Selected
TC
Temp.
4m 38s
400
ºC
80
%
400ºC Selected
Protection
Hot Air Temp. Air Flow Selec.
TC
Suction
OK
17:14
20
ºC
Power
45%
120ºC Selected
TC
Temp.
4m 38s
400
ºC
80
%
400ºC Selected
Protection
Hot Air Temp. Air Flow Selec.
By pressing Graphics in the main MENU, temperature and power fi gures in real time
are displayed. This helps you decide which tip to use to obtain the best quality solder
joints.
Graphics
Temperature
Power (%) External
Temp.
Ext. temp
Export Graphics
Insert a USB flash drive into the USB-A
connector to save your soldering process
in csv format.
The fi rst system to optimize traceability in soldering
- Get greater quality and control in your production
- Manage your whole soldering process remotely in real time
Station Update
Download the JBC Update File from
www.jbctools.com/software.html
Insert the USB flash drive with the file down-
loadedto the station.
Files
Update
6
We recommend using the protector + tripod We recommend using the manual extractors
Protectors & Extractors
1 2 3 4
For small components (fig. 1 and 2). For large components (fig. 3 and 4).
Position the extractor with the
appropriate suction cup and
press the suction button.
Heat the component. The component lifts off
automatically when the
solder melts.
Operation
3. Extracting1. Placing 2. Heating
Adjustable Stand
Adjust the tool holder angle to suit your work position.
www.jbctools.com
7
IPC* does not recommend exceeding ramp-up rates
over 3 - 4 °C / sec (5 - 7 °F / sec) so as to reduce the
risk of thermal stress on the PCB.
* IPC was founded in the U.S. in 1957 as the Institute for
Printed Circuits.
Using the Thermocouple type K
You can choose from two work modes:
Regulation: the station regulates the air
temperature automatically to maintain the
External Thermocouple (TC) temperature.
Fix the TC with Kapton Tape (Ref. PH217) as near as possible to the component
being worked on. If Kapton tape is not ESD you must use an ionizer.
Protection: the station cuts the air supply off
when the External Thermocouple (TC)
temperature is reached.
Connect a TC type K (PH218) to the station and use it as a protection or regulation sensor.
You can define its use mode by means of the “Ext TC mode” option in the “Tool” menu.
Extractor Desk
Ref. 0008752
Protectors and extractors not included.
This accessory lets you quickly switch
between different models of extractors and
protectors.
There are two drawers for storage.
8
Turn the tool off
and handle with
care. The heating
element and the
nozzle are still hot.
2
1
Quick Nozzle Changer
Changing nozzles quickly and safely.
*Ref. Shape Ø Size
(mm)
Ø
Size (in)
*TN9209 Straight Ø 3 Ø 0.12
*TN9208 Straight Ø 4 Ø 0.16
*TN9080 Straight Ø 5 Ø 0.20
TN9787 Bent Ø 3 Ø 0 .12
TN9785 Bent Ø 4 Ø 0.16
TN9782 Bent Ø 5 Ø 0.20
TN8851 Bent Ø 3mm 4 Ø 0.12 45º
TN8905 Bent Ø 4 mm 45º Ø 0.16 45º
TN9561 Bent Ø 5 mm4 Ø 0.20 45º
Straight Bent
* Included in TE Accessory set (Ref. 0010300)
Ø mm Ø mm
www.jbctools.com
9
1. Ensure that the tool is turned off.
2. Use a spanner to unscrew the nut.
3. Make sure that the new heater tube fits into
the grooves in the socket.
4. Tighten the screw.
Changing the TE-TB Heater Hose Set
Only perform this operation when the element is cold and the unit is disconnected from the mains.
1. Loosen the screw.
2. Pull the heating element away from the handle.
3. Connect the new heating element, ensuring it is pushed all the way in.
4. Tighten the screw.
Replacing the Heating Element
Precision Heater
Hose Set
Ref. TE-TB
Heating Element
Ref. 0012374
(100V - 230V - 120V)
TE Handle
Ref. TE-B
10
Maintenance
Clean periodically
Fuse holder
Fuse holder
Fuse
Before carrying out maintenance, always allow the equipment to cool.
- Clean the station screen with a glass cleaner
or a damp cloth.
- Use a damp cloth to clean the casing and the
tool. Alcohol can only be used to clean the
metal parts.
- Periodically check that the metal parts of the
tool and stand are clean so that the station
can detect the tool status.
- Periodically check all cables and tubes.
- Replace a blown fuse as follows:
1. Pull off the fuse holder and remove the
fuse. If necessary use a tool to lever it off.
2. Insert the new fuse into the fuse holder
and return it to the station.
- Replace any defective or damaged pieces. Use original JBC spare parts only.
- Repairs should only be performed by a JBC authorized technical service.
www.jbctools.com
11
Safety
- Do not use the units for any purpose other than soldering or rework. Incorrect use may cause fire.
- The power cord must be plugged into approved bases. Be sure that it is properly grounded
before use. When unplugging it, hold the plug, not the wire.
- Do not work on electrically live parts.
- The tool should be placed in the stand when not in use in order to activate the sleep mode.
The soldering tip, the metal part of the tool and the stand may still be hot even when the station
is turned off. Handle with care, including when adjusting the stand position.
- Do not leave the appliance unattended when it is on.
- Do not cover the ventilation grills. Heat can cause inflamable products to ignite.
- Avoid flux coming into contact with skin or eyes to prevent irritation.
- Be careful with the fumes produced when soldering.
- Keep your workplace clean and tidy. Wear appropriate protection glasses and gloves when
working to avoid personal harm.
- Utmost care must be taken with liquid tin waste which can cause burns.
- This appliance can be used by children over the age of eight and also persons with reduced
physical, sensory or mental capabilities or lack of experience provided that they have been given
adequate supervision or instruction concerning use of the appliance and understand the hazards
involved. Children must not play with the appliance.
- Maintenance must not be carried out by children unless supervised.
It is imperative to follow safety guidelines to prevent electric
shock, injury, fire or explosion.
12
产品中有名称及含
有害物质含量
部件名称
有害物质
铅(Pb) 汞(Hg) 镉(Cd) 六价铬
(Cr(VI))
多溴联苯
(PBB)
多溴二苯醚
(PBDE)
烙铁头 OOOOO O
手柄 OOOOO O
电源线 OOOOO O
主机 OOOOO O
电源插座 OOOOO O
保险丝 OOOOO O
主开关 OOOOO O
电位连接 X O O O O O
变压器 OOOOO O
线路板 X O O O O O
O 表示该有害物质在该部件所有均质材料中的含量均在GB/T 26572 规定的限量要求以下。
X 表示该有害物质至少在该部件的某一均质材料中的含量超出GB/T 26572 规定的限量要求。
www.jbctools.com
13
Notes
14
TESE-1QA 100V - 120V 50/60Hz. Input fuse: 8A. Rated current: 7A
TESE-2QA 230V 50/60Hz. Input fuse: 4A. Rated current: 3A
- Temperature selection: Room temp. / 150 - 450 °C (300 - 840 °F)
- Nominal power: 700W
- Cool mode: T off. Used to blow air at room temperature
- Ambient operating temp.: 10 - 50 ºC (50 - 122 ºF)
- Air flow regulation: 2 - 17 SLPM
- Vacuum: 30% / 228 mmHg / 9 inHg
- Connectors: USB-A / USB-B
RJ12 for RS232
Pedal for P-005
- Control Unit Weight: 1,9 kg (10.86 lb)
- Control Unit Dimensions: 148 x 184 x 140 mm (5.83 x 7.24 x 5.51 in)
- Total Package: 474 x 368 x 195 mm / 4,62 kg
18.7 x 14.5 x 7.7 in / 10.2 lb
Complies with CE standards.
ESD protected.
www.jbctools.com
15
This product should not be thrown in the garbage.
In accordance with the European directive 2012/19/EU, electronic equipment at the end of its life must
be collected and returned to an authorized recycling facility.
Warranty
JBC’s 2 year warranty covers this equipment against
all manufacturing defects, including the replacement
of defective parts and labour.
Warranty does not cover product wear or misuse.
In order for the warranty to be valid, equipment must
be returned, postage paid, to the dealer where it was
purchased.
Get 1 extra year JBC warranty by registering here:
https://www.jbctools.com/productregistration/
within 30 days of purchase.
40 mm
50 mm
60 mm
80 mm
100 mm
130 mm 130 mm
para manuales - color gris
200 mm
300 mm
0019 044-0521
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

jbc TESE-QA Precision Hot Air Station extractor desk Instrukcja obsługi

Typ
Instrukcja obsługi