SJE RHOMBUS 1007457 Instrukcja obsługi

Typ
Instrukcja obsługi
TANK ALERT
®
I ALARM SYSTEM
Easy to Install Liquid Level Alarm System for Indoor Use
9500095I Rev 01/23
© 2020 SJE, Inc. All Rights Reserved.
SJE Rhombus is a trademark of SJE, Inc.
This alarm system monitors liquid levels in lift pump chambers, sump pump
basins, holding tanks, sewage, agricultural, and other water applications.
The Tank Alert® I alarm system can serve as a high or low level alarm depending
on the oat switch model used.
The alarm horn sounds when a potentially threatening liquid level condition
occurs. The horn can be silenced, but the warning light remains on until the
condition is remedied. A green "power on" light indicates power to the alarm
panel.
FEATURES
NEMA 1 enclosure, designed for ease of installation, rated for indoor use
Red "alarm" light, green "power on" light, alarm "test" switch, and horn
"silence" switch
Alarm horn sounds at 86 decibels at 10 feet (3 meters)
Can be used with any UL Listed / Recognized switching mechanism
rated to include 1 amp, 12 VAC load
Alarm system (when installed on separate circuit) operates even if the
pump circuit fails
Switching mechanism operates on low voltage and is isolated from the
power line to reduce the possibility of shock
OPTIONS
When ordered with the alarm, this system is available with:
Alternate oat switch models for high or low level warning
120 VAC primary voltage or 230 VAC primary voltage (230 VAC model is
not UL Listed or CSA Certied)
www.sjerhombus.com • Toll Free 888-342-5753 D.11
Indoor Alarms
D.12
H = High Level L = Low Level X = No Float SPKT = Splice Kit MASTER CARTON holds 16 boxed units.
TANK ALERT
®
I - Easy-to-install liquid level alarm system for indoor use.
Part # Description (120V) Shipping Weight
1007457 101-01H (120 VAC w/15’ SJE SignalMaster® High Level) 3.58 lbs
1009207 101-01HSPKT (120 VAC w/15’ SJE SignalMaster® High Level) with splice kit 3.58 lbs.
1003104 101-01H (120 VAC w/15’ Sensor Float® High Level) 3.58 lbs.
1003365 101-01L (120 VAC w/15’ Sensor Float® Low Level) 3.58 lbs.
1002235 101-01X (120 VAC no oat) 2.14 lbs.
Part # Description (230V) Shipping Weight
1008009 101-02H (230 VAC w/15’ SJE SignalMaster® High Level) 3.58 lbs.
1003364 101-02H (230 VAC w/15’ Sensor Float® High Level) 3.58 lbs.
1005420 101-02L (230 VAC w/15’ Sensor Float® Low Level) 3.58 lbs.
1005419 101-02X (230 VAC no oat) 2.14 lbs.
SPECIFICATIONS
VOLTAGE FOR 120 VAC MODEL:
PRIMARY: 120 VAC, 50/60 Hz, 5 watts max. (alarm condition)
SECONDARY: 12 VAC
VOLTAGE FOR 230 VAC MODEL (not UL Listed or CSA Certied):
PRIMARY: 230 VAC, 50/60 Hz, 5 watts max. (alarm condition)
SECONDARY: 12 VAC
ALARM ENCLOSURE: 6 x 4 x 2.5 inch (15.24 x 10.16 x 6.35 cm),
NEMA 1 metal
ALARM HORN: 86 decibels at 10 feet (3 meters)
POWER CORD: 6 foot (1.8 meter)
FLOAT SWITCH CONNECTION TERMINAL: For oat switch connection
only. Do not apply power.
(Voltage across terminals is
12 VAC.)
FLOAT SWITCH: SJE SignalMaster® control switch with mounting clamp
CABLE: 15 feet (4.57 meters), exible 18 gauge, 2 conductor (UL)
SJOW, water-resistant (CPE)
FLOAT: 2.74 inch diameter x 4.83 inch long (7 cm x 12.3 cm), high
impact, corrosion resistant polypropylene housing for use
in sewage and non-potable water up to 140°F (60°C)
MAXIMUM WATER DEPTH: 30 feet (9 meters), 13 psi
ELECTRICAL: 5 amps, 125 VAC/250 VAC, 50/60 Hz
CONTROL SWITCH OPTIONS
The Tank Alert® I alarm system comes standard with a 15 foot SJE SignalMaster® control switch with mounting clamp. Other oat switches are available. See
control switch section of the catalog. To determine the price of alarm with an alternate oat, add the price of the part number with "no oat" to the price of the oat
switch.
www.sjerhombus.com • email: customer[email protected] SEE PRICE BOOK FOR PRICING.