Flash professional P7110029 Instrukcja obsługi

Typ
Instrukcja obsługi
USER MANUAL / INSTRUKCJA OBSŁUGI
SQUARE 250 IP
P7110029
SQUARE 250 IP / P7110029
www.flash-butrym.pl
1
Table of contents
1 Introduction ...................................................................................................................................................... 2
2 Safety information ........................................................................................................................................... 2
3 Product information ........................................................................................................................................ 2
3.1 Features ....................................................................................................................................................... 2
3.2 Specification ................................................................................................................................................ 2
4 Installation ........................................................................................................................................................ 3
5 Connections ...................................................................................................................................................... 3
5.1 Connecting DMX signal............................................................................................................................. 3
5.2 Voltage specification .................................................................................................................................. 4
5.3 Connecting power supply ........................................................................................................................ 4
6 Operation manual ............................................................................................................................................ 4
6.1 Control panel .............................................................................................................................................. 4
6.2 Auto mode programs (macros) ................................................................................................................. 4
6.3 DMX channel list ........................................................................................................................................ 5
Spis treści
1 Wprowadzenie ................................................................................................................................................. 7
2 Zasady bezpieczeństwa .................................................................................................................................. 7
3 Informacje o produkcie ................................................................................................................................... 7
3.1 Funkcje ......................................................................................................................................................... 7
3.2 Specyfikacja ................................................................................................................................................. 7
4 Instalacja ........................................................................................................................................................... 8
5 Połączenia ......................................................................................................................................................... 8
5.1 Podłączenie sygnału DMX ........................................................................................................................ 8
5.2 Specyfikacja zasilania ................................................................................................................................. 9
5.3 Podłączanie zasilania ................................................................................................................................. 9
6 Instrukcja użytkowania ................................................................................................................................... 9
6.1 Panel sterowania ........................................................................................................................................ 9
6.2 Tryb Auto mode lista programów (makr) ............................................................................................ 9
6.3 Lista kanałów DMX.................................................................................................................................. 10
www.flash-butrym.pl 2
1 INTRODUCTION
Thank you for purchasing SQUARE 250 IP. For safety reasons and to ensure the trouble-free operation,
carefully read the instructions.
2 SAFETY INFORMATION
1. Installation should be done by qualified personnel in order to minimize the risk of
accidental electric shock
2. Disconnect the power supply before installation.
3. Before connecting the unit to the mains, make sure it is not damaged mechanically. If you
notice any signs of damage you should contact your dealer immediately. Do not connect
the device to the mains.
4. Do not use the device in high humidity conditions and at temperatures above 40° C
5. The device must be installed on stable structures
6. Always use steel security cable to attach the device to a stable structure
7. Do not connect power supply to more than 4 devices in series.
3 PRODUCT INFORMATION
3.1 Features
Dedicated Color Temperature Correction channel (CTC)
2200K to 5200K color temperature (warm to natural white)
16-bit dimming resolution
Various dimming curves for smooth dimming in 8-bit mode
Dim delay (light bulb simulation)
Full DMX signal regeneration
Electronic protection against overheating
THEATRE or DISCO cooling volume modes.
Permanent color correction
Native support for optional wireless DMX module
3.2 Specification
Power consumption: 250W
Power supply voltage: 100 - 245V
Voltage frequency: 50/60Hz
Diode type: 2xWhite COB
Number of diodes: 1
Diode power: 250W
Display: Color LCD
Color: Warm white (2200K), natural white (5200K)
Beam angle (min): 3
Beam angle (max): 37°
Dimming: Linear: 0 - 100%
Flash frequency (min): 1Hz
Flash frequency (max): 20Hz
DMX standard: DMX 512
Control interface: 4 buttons
SQUARE 250 IP / P7110029
www.flash-butrym.pl
3
Operating modes: DMX512, Auto, Sound-controlled, Master / Slave
Features: 16-bit dimming, various dimming curves, bulb simulation, DMX Signal regeneration,
Electronic protection against overheating
AC IN: powerCON
AC OUT: powerCON
DMX IN: XLR - 3 pin
DMX OUT: XLR - 3 pin
IP Rating: IP20
Housing made: ABS
Cooling: Active
Height [cm]: 28
Width [cm]: 27
Depth [cm]: 24
Weight [kg]: 3,4
Weight with packaging [kg]: 4,2
4 INSTALLATION
After removing the packaging, check if the device was not damaged during transport. Before connecting to
the mains, make sure that the device is securely mounted. The manufacturer is not responsible for damage
caused by unstable mounting.
CAUTION! Always use steel security cable to attach the device to a stable structure.
Ensure proper connection to the mains and proper grounding. Make sure that the electrical parameters are
consistent with device requirements. All activities, including connecting the device to the mains must be
performed by qualified personnel.
5 CONNECTIONS
The device is equipped with the following interfaces:
1. DMX (in/out): XLR 3-pin socket
2. Power (in/out): powerCON socket
5.1 Connecting DMX signal
The connection is performed using cable with XLR-female -> XLR-Male plugs.
www.flash-butrym.pl 4
5.2 Voltage specification
Input Voltage
Total Power
Frequency
100~245V
250W
50/60Hz
5.3 Connecting power supply
The connection is performed using power cable with PowerCon connector (included).
The device must be operated by qualified personnel. Make sure that the power grid supply parameters are
consistent with device parameters and limitations are not exceeded.
CAUTION! In the case of cable damage do not attempt to repair. Replacement or repair can be made only
on the manufacturer or by a person with appropriate permissions.
Maximum number of devices connected in series: 4
6 OPERATION MANUAL
6.1 Control panel
The control panel is equipped with LCD display and 4 control buttons with the following functions:
1. ESCgo back from the selected options, go to upper menu, cancel changes
2. DOWN choose option, edit parameter
3. UP choose option, edit parameter
4. ENTER edit selected option, confirm changes
6.2 Auto mode programs (macros)
1. Calibrated white 2200K
2. Calibrated white 2300K
3. Calibrated white 2400K
4. Calibrated white 2500K
5. Calibrated white 2600K
6. Calibrated white 2700K
7. Calibrated white 2800K
8. Calibrated white 2900K
9. Calibrated white 3000K
10. Calibrated white 3100K
11. Calibrated white 3200K
SQUARE 250 IP / P7110029
www.flash-butrym.pl
5
12. Calibrated white 3400K
13. Calibrated white 3600K
14. Calibrated white 3800K
15. Calibrated white 4000K
16. Calibrated white 4200K
17. Calibrated white 4400K
18. Calibrated white 4600K
19. Calibrated white 4800K
20. Calibrated white 5000K
21. Calibrated white 5200K
22. Program 1
23. Program 2
24. Program 3
25. Program 4
26. Program 5
27. Program 6
28. Program 7
29. Program 8
30. Program 9
31. Program 10
32. Program 11
33. Program 12
6.3 DMX channel list
CH mode-1 mode-2 mode-3 mode-4 mode-5 mode-6 mode-7 mode-8 mode-9
1 Dimmer Dimmer Dimmer Dimmer Dimmer Dimmer Dimmer 2200K 2200K
2 CTC Dimmer
fine CTC Dimmer
fine
Dimmer
fine 2200K Dimmer
fine 5200K 2200K
fine
3 CTC Strobe* CTC CTC 5200K 2200K 5200K
4 Macro* Strobe* 2200K 5200K
5200K
fine
5 Macro* 5200K
6 Strobe*
7 Macro*
Strobe Channel DMX values
0-10: no function
11-255: Strobe, slow to fast
www.flash-butrym.pl 6
Macro Channel - DMX values
0-5: no function
6-10: Calibrated white 2200K
11-15: Calibrated white 2300K
16-20: Calibrated white 2400K
21-25: Calibrated white 2500K
26-30: Calibrated white 2600K
31-35: Calibrated white 2700K
36-40: Calibrated white 2800K
41-45: Calibrated white 2900K
46-50: Calibrated white 3000K
51-55: Calibrated white 3100K
56-60: Calibrated white 3200K
61-65: Calibrated white 3400K
66-70: Calibrated white 3600K
71-75: Calibrated white 3800K
76-80: Calibrated white 4000K
81-85: Calibrated white 4200K
86-90: Calibrated white 4400K
91-95: Calibrated white 4600K
96-100: Calibrated white 4800K
101-105: Calibrated white 5000K
106-110: Calibrated white 5200K
111-115: Macro 1 - change
116-120: Macro 2 - ramp
121-125: Macro 3 - fade
126-130: Macro 4 - redshift
131-135: Macro 5 - puls
136-140: Macro 6 - CTO
141-145: Macro 7 - Flash
146-150: Macro 8 - Random
151-255: Blackout
SQUARE 250 IP / P7110029
www.flash-butrym.pl
7
1 WPROWADZENIE
Dziękujemy za zakup urządzenia SQUARE 250 IP. Ze względów bezpieczeństwa oraz w celu zapewnienia
bezawaryjnej pracy urządzenia należy dokładnie zapoznać się z instrukcją.
2 ZASADY BEZPIECZEŃSTWA
1. Instalacja powinna być przeprowadzana przez wykwalifikowany personel, aby
zminimalizować ryzyko przypadkowego porażenia prądem
2. Przed instalacją należy odłączyć urządzenie od sieci
3. Przed podłączeniem urządzenia do sieci energetycznej należy sprawdzić, czy nie jest ono
uszkodzone mechanicznie. Jeżeli widoczne jakiekolwiek ślady uszkodzenia należy
niezwłocznie skontaktować się z dystrybutorem. Nie podłączać urządzenia do sieci
elektrycznej.
4. Nie należy korzystać z urządzenia w warunkach dużej wilgotności powietrza oraz w
temperaturze powyżej 40° C
5. Urządzenie należy instalować na stabilnych konstrukcjach
6. Należy zawsze używać stalowej linki zabezpieczającej w celu zapewnienia dodatkowego
mocowania do stabilnej konstrukcji.
7. Nie łączyć szeregowo kablem zasilającym więcej niż 4 urządzenia.
3 INFORMACJE O PRODUKCIE
3.1 Funkcje
Dedykowany kanał kontroli temperatury barwy (CTC)
Zakres temperatury światła białego od 2200K do 5200K (od ciepłego do naturalnego)
16-bitowa rozdzielczość sterowania jasnością
Możliwość zmiany charakterystyki sterowania jasnością (krzywe jasności)
Tryb opóźnienia reakcji na regulację jasności (symulacja żarówki)
Pełna regeneracja sygnału DMX
Elektroniczne zabezpieczenie przed przegrzaniem
Możliwość wyboru spośród dwóch trybów głośności chłodzenia: THEATRE lub DISCO
Możliwość stałej korekcji barwy
Natywna obsługa opcjonalnego bezprzewodowego modułu DMX
3.2 Specyfikacja
Pobór mocy: 250W
Napięcie zasilania: 100 - 245V
Częstotliwość napięcia: 50/60Hz
Typ diody: 2x biała COB
Ilość diod: 1
Moc diody: 250W
Wyświetlacz: LCD Kolorowy
Barwa: Ciepła biała (2200K), naturalna biała (5200K)
Kąt świecenia (min): 37°
Kąt świecenia (max): 37°
Ściemnianie: Płynne: 0 - 100%
Błysk - częstotliwość minimalna: 1Hz
www.flash-butrym.pl 8
Błysk - częstotliwość maksymalna: 20Hz
Standard DMX: DMX 512
Sterowanie: 4 przyciski
Tryby pracy: DMX512, Auto, Sterowanie dźwiękiem, Master / Slave
Funkcje: 16-bit sterowanie jasnością, płynne sterowanie jasncią (możliwość wyboru krzywej
charakterystyki sterowania), symulacja żarówki (opóźniona reakcja na zmianę
jasności)Regeneracja sygnału DMX, Elektroniczne zabezpieczenie przed przegrzaniem
AC IN: powerCON
AC OUT: powerCON
DMX IN: XLR - 3 pin
DMX OUT: XLR - 3 pin
Stopień ochrony IP: IP20
Rodzaj obudowy: ABS
Chłodzenie: Aktywne
Wysokość [cm]: 28
Szerokość [cm]: 27
Głębokość [cm]: 24
Waga [kg]: 3,4
Waga z opakowaniem [kg]: 4,2
4 INSTALACJA
Po wyjęciu urządzenia z opakowania należy sprawdzić czy nie zostało ono uszkodzone podczas
transportu.
Przed podłączeniem do sieci elektrycznej należy upewnić się, że urządzenie zamocowane jest stabilnie.
Producent nie ponosi odpowiedzialności za uszkodzenia spowodowane niestabilnym zamocowaniem
urządzenia.
UWAGA! Należy zawsze używać stalowej linki zabezpieczającej w celu zapewnienia dodatkowego
mocowania do stabilnej konstrukcji.
Podczas korzystania z urządzenia należy zadbać o poprawne podłączenie go do sieci elektrycznej oraz
prawidłowe uziemienie. Należy upewnić się, że parametry sieci elektrycznej zgodne z wymaganiami
urządzenia. Wszelkie czynności obejmujące obsłu w zakresie podłączania urządzenia do sieci
elektrycznej powinny być wykonywane przez wykwalifikowany personel.
5 POŁĄCZENIA
Urządzenie wyposażone jest w następujące interfejsy:
1. DMX (wejście/wyjście) ącza: XLR 3-pin
2. Zasilanie (wejście/wyjście) - złącza: powerCON
5.1 Podłączenie sygnału DMX
Połączenie odbywa się przy użyciu przewodu z wtyczkami XLR-Żeński -> XLR-Męski
SQUARE 250 IP / P7110029
www.flash-butrym.pl
9
5.2 Specyfikacja zasilania
Napięcie zasilania
Pobór mocy
Częstotliwość zasilania
100~245V
200W
50/60Hz
5.3 Podłączanie zasilania
Połączenie odbywa się przy użyciu przewodu zakończonego z jednej strony wtyczką sieci elektrycznej i
wtyczką typu powerCON z drugiej strony (w zestawie).
Urządzenie musi być obsługiwane przez wykwalifikowany personel. Należy upewnsię, że parametry
zasilania sieci energetycznej są zgodne z parametrami urządzenia i nie zostają przekroczone ograniczenia
dotyczące poboru energii elektrycznej z sieci.
UWAGA! W przypadku uszkodzenia przewodu nie należy dokonywać samodzielnej naprawy. Wymiana
lub naprawa może być wykonana jedynie w serwisie producenta lub przez osobę z odpowiednimi
uprawnieniami.
Maksymalna ilość urządzpołączonych szeregowo kablem zasilającym: 4
6 INSTRUKCJA UŻYTKOWANIA
6.1 Panel sterowania
Panel sterowania wyposażony jest w wyświetlacz LCD oraz w 4 przyciski sterujące o następucych
funkcjach:
1. ESCwyjście do menu wyższego poziomu, anulowanie zmian
2. DOWN wybór opcji, edycja parametru
3. UP wybór opcji, edycja parametru
4. ENTER edycja wybranej opcji, zatwierdzenie zmian
6.2 Tryb Auto mode lista programów (makr)
1. Kalibrowany biały 2200K
2. Kalibrowany biały 2300K
3. Kalibrowany biały 2400K
4. Kalibrowany biały 2500K
www.flash-butrym.pl 10
5. Kalibrowany biały 2600K
6. Kalibrowany biały 2700K
7. Kalibrowany biały 2800K
8. Kalibrowany biały 2900K
9. Kalibrowany biały 3000K
10. Kalibrowany biały 3100K
11. Kalibrowany biały 3200K
12. Kalibrowany biały 3400K
13. Kalibrowany biały 3600K
14. Kalibrowany biały 3800K
15. Kalibrowany biały 4000K
16. Kalibrowany biały 4200K
17. Kalibrowany biały 4400K
18. Kalibrowany biały 4600K
19. Kalibrowany biały 4800K
20. Kalibrowany biały 5000K
21. Kalibrowany biały 5200K
22. Program 1
23. Program 2
24. Program 3
25. Program 4
26. Program 5
27. Program 6
28. Program 7
29. Program 8
30. Program 9
31. Program 10
32. Program 11
33. Program 12
6.3 Lista kanałów DMX
CH mode-1 mode-2 mode-3 mode-4 mode-5 mode-6 mode-7
mode-
8
mode-9
1 Ściemnianie Ściemnianie Ściemnianie Ściemnianie Ściemnianie Ściemnianie Ściemnianie 2200K 2200K
2 CTC Ściemnianie
ust. precyz. CTC Ściemnianie
ust. precyz.
Ściemnianie
ust. precyz. 2200K Ściemnianie
ust. precyz. 5200K 2200K ust.
precyz.
3 CTC Strobe* CTC CTC 5200K 2200K 5200K
4 Macro* Strobe* 2200K 5200K
5200K ust.
precyz.
5 Macro* 5200K
6 Strobe*
7 Macro*
SQUARE 250 IP / P7110029
www.flash-butrym.pl
11
Kanał Strobowartci DMX
0-10: brak funkcji
11-255: Strobo, wolno-szybko
Kanał Macro wartości DMX
0-5: brak funkcji
6-10: Kalibrowany biały 2200K
11-15: Kalibrowany biały 2300K
16-20: Kalibrowany biały 2400K
21-25: Kalibrowany biały 2500K
26-30: Kalibrowany biały 2600K
31-35: Kalibrowany biały 2700K
36-40: Kalibrowany biały 2800K
41-45: Kalibrowany biały 2900K
46-50: Kalibrowany biały 3000K
51-55: Kalibrowany biały 3100K
56-60: Kalibrowany biały 3200K
61-65: Kalibrowany biały 3400K
66-70: Kalibrowany biały 3600K
71-75: Kalibrowany biały 3800K
76-80: Kalibrowany biały 4000K
81-85: Kalibrowany biały 4200K
86-90: Kalibrowany biały 4400K
91-95: Kalibrowany biały 4600K
96-100: Kalibrowany biały 4800K
101-105: Kalibrowany biały 5000K
106-110: Kalibrowany biały 5200K
111-115: Macro 1 - change
116-120: Macro 2 - ramp
121-125: Macro 3 - fade
126-130: Macro 4 - redshift
131-135: Macro 5 - puls
136-140: Macro 6 - CTO
141-145: Macro 7 - Flash
146-150: Macro 8 - Random
151-255: Cze