Novus NVR-4532-H4/F-II Instrukcja obsługi

Typ
Instrukcja obsługi
Users manual
N CONTROL 4000
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
2
N Control 4000 Users manual version 1.0
TABLE OF CONTENTS
TABLE OF CONTENTS ...................................................................................... 2
1. FOREWORD INFORMATION ...................................................................... 3
1.1. Main characteristics ..................................................................................... 3
1.2. Hardware requirements ............................................................................... 3
2. INSTALLATION AND LAUNCHING SOFTWARE ................................... 4
2.1. Installation of the software .......................................................................... 4
2.2. Software startup ........................................................................................... 6
2.3. Login window .............................................................................................. 6
2.4. Record parition settings ............................................................................... 8
2.5. Application interface ................................................................................... 9
2.6. Server processes ........................................................................................ 11
3. BASIC FUNCTIONALITY SUPPORT ........................................................ 12
3.1. Device adding ............................................................................................ 12
3.2. Change the dvices IP address ................................................................... 14
3.3. Manually adding a device ......................................................................... 14
3.4. Adding devices to the zone ....................................................................... 15
3.5. Removing a dvice from the list. ................................................................ 15
4. DISPLAYING IMAGES FROM DEVICES ................................................ 16
4.1. Live view .................................................................................................. 16
4.2. Records playback ...................................................................................... 19
4.3. Copying recordings from the playback window ....................................... 21
4.4. Copying recordis to the remote device ..................................................... 22
5. Line Crossing Counting .................................................................................. 23
5.1. Configuration ot the line crossing counter in the N Control 6000 soft, .... 23
5.2. Setting an operation schedule in the N Contorl 60000 software ............... 24
5.3. Real-time Statistics .................................................................................... 26
5.4. Sumaery Statistics ..................................................................................... 27
5.5. Historical Statistics .................................................................................... 28
N Control 4000 Users manual version 1.0
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
3
FOREWORD INFORMATION
1. FOREWORD INFORMATION
1.1. Main characteristics
Software for operating and managing NOVUS 4000 series NVRs, NHDRs and IP cameras.
Group device management;
Remote configuration of devices;
Multiscreen environment;
Flexible camera layouts
Site maps features;
Advanced user account settings;
Local recording and playback of recordings;
Support for alarm event scenarios;
Configuration and management of advanced image analysis functions, e.g. face recognition
and others.
1.2. Hardware requirements
Below are the requirements for the specification of the computer unit for the N Control 4000 software:
1. Intel Pentium4 [email protected] GHz CPUor higher.
2. RAM memory 4GB DDR4 ECC or higher.
3. OS: Microsoft Windows 7/8.1/10 (32/64 bit)/ Windows Server 2008 (64 bit) / MacOS 11.6 or
higher .
4. 100/1000 Mb/s network card.
5. RADEON X700 Series 256MB Graphics Card or better.
6. . Minimum 500 GB SATA hard drive.
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
4
N Control 4000 Users manual version 1.0
INSTALLATION AND LAUNCHING OF THE SOFTWARE
2. INSTALLATION AND LAUNCHING OF THE SOFTWARE
2.1. Installation of the software.
Download N Comtrol 4000 from www.novuscctv.com and save it on the local drive. Run the software
to begin the installation. Setup windows is displayed (as shown below). In the next installation steps,
the following windows will appear:
software installation path (default path is C:\Program Files (x86)\NOVUS\N Control 4000)
software shortcut location in the Start Menu
N Control 4000 Users manual version 1.0
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
5
INSTALLATION AND LAUNCHING OF THE SOFTWARE
adding a shortcut to desktop or menu bar
summary of selected settings
The Install button will start the installation process.
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
6
N Control 4000 Users manual version 1.0
INSTALLATION AND LAUNCHING OF THE SOFTWARE
After the operation is completed, the following window will appear confirming successful installation.
If the Launch N Control 4000 option is selected, the program will start automatically just after
Finish button is clicked.
2.2. First launch
The first time the N Control 4000 software is launched, you must define a supervisor password.
N Control 4000 Users manual version 1.0
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
7
INSTALLATION AND LAUNCHING OF THE SOFTWARE
Enter the password in the Password field. It can contain uppercase and lowercase letters, numbers and
special characters. The Password Strength line shows information about the password strength while
typing. It is displayed in the form of a color:
red - the password is weak
yellow - the password is medium
green - the password is strong
The password must contain at least 8 characters.
To confirm, enter the password again in the Confirm Password field.
If the Auto Login After Registration checkbox is marked, the software will not require password
authentication when starting up.
After pressing the Next button, a window appears where you must select 2 security questions and
define the answers - knowing these answers will allow you to define new password if you lose the old
one.
The Finish button will complete the first login process and the login window will appear. This
window also appears every time you start the software.
N Control 4000 Users manual version 1.0
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
8
2.3. Running the software.
The N Control 4000 software can be launched by clicking on the N Control 4000 icon on the desktop,
in the Menu bar, in the place defined during installation in the Start Menu or in the installation
directory (the default path is C:\Program Files (x86)\NOVUS\N Control 4000)
2.4. Login window
After launching the software, a login window will appear.
In the left part of the window, you can select the login mode. The Account Login mode is shown by
default, which allows users defined on the computer to log in (only admin at the beginning), which
can manage multiple devices.
In the upper part of the window, select a user and enter his password. If you check the Remember
Password box, the user's password will be remembered on the computer, you will not have to type it
the next time you log in. By checking the Auto Login box, the login window will not appear at the
next startup - the login process for this user will be automatic. The Login button will log the user in.
At the bottom, the Forgot Password? allows to redefine the administrator password using security
questions defined at the first launch (see chapter 2.2).
INSTALLATION AND LAUNCHING OF THE SOFTWARE
N Control 4000 Users manual version 1.0
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
9
Device Login mode allows to log in to a single device. In this mode, you do not need to set up an
account on the computer. You just log in to the account set up on the camera or recorder, you want to
connect.
It is required to provide the IP address of the device or P2P ID code, HTTP port set on the recorder (by
default port 80), username and password. If you check the Remember Password box, the user's
password will be remembered on the computer, you will not have to enter it the next time.
This mode has limited functionality. The next part of this manual describes the full functionality menu
after logging in the Device Login mode.
INSTALLATION AND LAUNCHING OF THE SOFTWARE
N Control 4000 Users manual version 1.0
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
10
2.5. Main menu
After starting the software and logging in to the user account, the main menu appears.
The following parts can be distinguished on the screen:
 Icons of open software tabs for quick navigation between them. The first houseicon is
responsible for the main menu.
 Icons of window resolution, switching between users, video player launch, and the standard
minimize, maximize, and close window icons.
 Current time, date and PC CPU load level.
 Operation icons activating the relevant tabs - live view, remote playback, local playback, log
search, AI event search, AI data analysis.
 Configuration icons enabling the relevant tabs - devices management, alarm configuration,
cruise settings, user accounts, recording locations, file management, system configuration, e-
map, AI configuration.
 Alarm bar displaying of alarm events.
INSTALLATION AND LAUNCHING OF THE SOFTWARE
N Control 4000 Users manual version 1.0
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
11
2.6. Language change
In order to change the software language, enter the system configuration. Press the System config icon
in the main menu.
The settings window will open (the appropriate icon will be visible in the upper bar), the General tab.
The default language is English. After pressing this field, a list of languages is displayed. Select the
language you are interested in and save the change using the Save button in the lower right corner.
Note! The language of the software will change on software restart. Close the program with a
cross in the upper right corner of the window and restart it.
INSTALLATION AND LAUNCHING OF THE SOFTWARE
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
12
N Control 4000 Users manual version 1.0
BASIC FUNCTIONS
3. BASIC FUNSTIONS
3.1. Adding devices
To add a device, select Device Management in the Main Menu. A menu opens where we can add or
remove devices.
In the upper right corner there are icons that allow to perform basic actions:
After pressing the icon, the device adding window will appear.
- exporting the list of devices to an .xml file.
- importing a list of devices from an .xml file.
- adding devices
- delete selected devices
N Control 4000 Users manual version 1.0
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
13
BASIC FUNCTIONS
Fill the specified fields:
device name helpful for the operator;
login type - IP address or P2P ID;
IP address or ID number - according to the type selected in the previous field;
connection protocol - Private for Novus 4000 series cameras and recorders, Onvif for other
devices;
device http port number;
username on the device;
user's password.
Press the Add button to confirm the data and the device appears on the list of devices.
After adding all devices, the table shows a list of devices with their names, IP addresses, device type
(IP camera, NHDR or NVR), connection protocol, device firmware version, connection status (green
mark means correct connection, gray means no connection), number port number, number of
channels, P2P ID number.
There are checkboxes on the left side that allow to select group of devices. There are icons on the right
side to make operations on single device:
- changing connection parameters with the device.
- device configuration. It allows to configure all device parameters in the same way as con-
necting to the device via a web browser.
- removing the device
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
14
N Control 4000 Users manual version 1.0
BASIC FUNCTIONS
Another way to add devices is to choose the Auto Search tab.
Select the protocol type and press the Search button. All devices in the LAN will be displayed. In
case of a large number of devices, you can limit the range of IP addresses using the Filter button.
The table in which the devices are displayed has the same columns as the list of added devices
described on the previous page. The Operation column is added at the end, which allows to add a
device using the + icon (in this case, enter the username and password) or using the pencil icon (you
can also edit the device's network parameters there). The last column contains checkboxes, which
allow to select a group of devices, and then use the Add button to connect them all at once (typing a
common username and password).
N Control 4000 Users manual version 1.0
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
15
BASIC FUNCTIONS
3.2. Creating user accounts
If the N Control 4000 software is used by more than one person, it is recommended to create separate
user accounts. Select the Account Management icon in the main menu,
A window with a list of users will open. Initially, there is only the admin user.
Additional users can be added using the + icon in the upper right corner.
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
16
N Control 4000 Users manual version 1.0
BASIC FUNCTIONS
Enter the username and define its password in the user adding window. Then, define its Basic Rights
(concerning software functions), Channels to which it is to have access (devices must be added
before) and Channel Rights (e.g. rights to watch "live", play records, download records, PTZ control,
etc.). After creating the user, it will appear in the list of users.
3.3. Main view
To watch the live view of connected channels, select the Main View icon in the main menu.
A window with a division will appear, to which you can freely assign a channel view. In the left part
there is a tree of connected devices. By expanding each of them, you can get a list of streams that can
be assigned to the right place by dragging onto the view window.
N Control 4000 Users manual version 1.0
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
17
BASIC FUNCTIONS
In the lower right corner there are auxiliary fields:
aspect selection box - original image, stretched, 4:3, 16:9
screen split selection - you can choose one or define your own divisions
floppy disk icon to save the defined view
enable full screen view. To exit it, press the Esc button on the keyboard or press the right mouse
button and turn off full-screen mode.
icon to enable the display of intelligent video analysis events configured in connected devices.
Views saved using the floppy disk icon can be quickly activated by switching to the next tab using the
icon located in the upper left corner.
NOTE! The N Control 4000 software allows to enable multiple views at once. The icon in the
upper bar has a number and a small + sign that allows to open another window. Having several
views open, you can grab them with the left mouse button and move them to another monitor as
a separate window. Each of these windows can be individually configured, switched to full-
screen mode, etc.
The icon next to it enables the PTZ camera control panel.
By hovering over the image from individual channels, a bar with icons appears at the bottom of the
window, allowing you to perform operations for a selected channel. The number and types of icons
depend on the connected camera.
In the example above, there are icons that allow to make a snapshot, enable video recording on the
computer, digital zoom, enable conversation (only if the camera has an audio output), mark the place
with a tag, play the last 10 minutes of recording from the camera (only if it is on currently being
recorded).
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
18
N Control 4000 Users manual version 1.0
BASIC FUNCTIONS
3.4. Remote playback
The N Control 4000 software enables playback of video recordings made on recorders. To do this,
select the Remote playback icon in the main menu.
A window will open where you can distinguished the following parts:
1. Recordings search mode - the first icon is responsible for playing video recordings, the second one
for browsing photos, the third one for browsing recordings marked with tags.
2. Tree of connected devices. All connected devices are here, whether they have recordings or not
(e.g. directly connected cameras). Select the channels you want to play records.
3. Device search field - in the case of a large system, you can search for individual channels using
their names.
4. Defining the video stream (main or secondary), recording type (all, alarm, triggered by the
intelligent analysis function - using the button, you can indicate a specific event) and the time
period.
After defining these parameters, press the Search button.
5. Windows for displaying records from selected channels.
6. Navigation buttons to control playback.
7. Timeline displaying the time and type of recordings, allowing to jump to the appropriate time of
records.
N Control 4000 Users manual version 1.0
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
19
BASIC FUNCTIONS
In order to find the appropriate event and play the record, use the procedure below:
1. Select the channels of interest for playback in the tree of connected devices (part 2 of the window).
2. Select the stream type, recordings and time period (part 4 of the window).
3. Press the Search button.
4. On the timeline, click on the axis of recordings of a particular channel (part 7 of the window). In the
upper right corner of the timeline there are + and - icons that allow to change the time range on the
axis.
5. Use the navigation buttons to control the playback, download the appropriate record.
Downloading recording files from the recorder for the selected channel
Synchronization of playing channels (to do this, you must first stop all playing channels)
Pause. When pressed, the icon changes to the play icon.
Marking the selected fragment of recordings for download. In place of this icon, a floppy disk
icon appears that saves the selected recording interval on the disk.
Stop playback.
Reverse playback. Pressing again will increase the reverse speed.
Slow playback. Pressing again will decrease the playback speed.
Quick play. Pressing again will increase the playback speed.
Moves the recording forward one frame.
Enables audio playback.
Smart Search
Plays all channels.
Stops all channels from playing.
Opens the panel for fisheye cameras.
Changing the division of the playback screen.
Enable full screen view. To exit it, press the Esc button on the keyboard or press the right mou-
se button and turn off full-screen mode.
2023-07-04 PF
AAT SYSTEMY BEZPIECZEŃSTWA Sp. z o.o.
431 Pulawska St., 02-801 Warsaw, Poland
tel.: +4822 546 0 546, [email protected]
www.novuscctv.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40

Novus NVR-4532-H4/F-II Instrukcja obsługi

Typ
Instrukcja obsługi

w innych językach