SFG64F1 port switch for 4 IP cameras
PL
Edition: 1 from 17.01.2020
Supercedes the edition: -----------
EN
Features:
6 ports switch
4 PoE ports 10/100/1000Mb/s (data transfer and power
supply)
1 port 10/100/1000Mb/s (UP LINK, TP)
1 port 10/100/1000Mb/s (UP LINK, SFP)
30 W for each PoE port, supports devices complaint
with the IEEE802.3af/at (PoE+) standard
Supports auto-learning and auto-aging of MAC
addresses (2K size)
Built-in switch mode power supply
PSD520115 52 V DC/1,15 A/60 W
Additional mounting elements
LED indication
warranty 2 year from the production date
Example of use.
1. Technical description
1.1. General description.
SFG64F1 is a 6-ports PoE switch designed to supply IP cameras operating in IEEE 802.3af/at standard. Automatic
detection of any devices powered in the PoE/PoE+ standard is enabled at the 1 4 ports of the switch. The UP LINK (5 and
SFP) ports is used for connection of another network device via of fiber optic (shall be used GBIC SFP port). The LEDs at the
front panel indicate the operation status (description in the table below).
The PoE technology ensures a network connection and reduces installation costs by eliminating the need to supply a
separate power cable for each device. This method allows supplying other network devices, such as IP phone, wireless access
point or router.
2
1.2 Block diagram.
Fig. 1. Block diagram.
1.3. Description of components and connectors.
Table 1. (see Fig.2)
Element no.
(Fig. 2)
Description
[1]
1 x UP LINK port (SFP)
[2]
1 x UP LINK port (TP)
[3]
4 x PoE ports (1÷4)
[4]
DC power supply socket
[5]
Additional mounting elements
Fig. 2. The enclosure view.
3
1.4. Technical parameters.
Table 2.
Ports
PoE power supply
Protocols, Standards
Bandwidth
Transmission method
Optical indication of operation
Power supply
Operating conditions
Dimensions
Additional equipment
Net/gross weight
Protection class
EN 60950-1:2007
Storage temperatur
Declarations
* The given value of 30 W per port is the maximum value. The total power consumption should not exceed 48 W.
2. Installation
2.1. Requirements
The unit should be mounted in confined spaces, in accordance with the 2nd environmental class, with normal relative
humidity (RH=90% maximum, without condensation) and temperature from -10°C to +40°C. Ensure the free flow of air around
the unit. The PSU shall work in a vertical position that guarantees sufficient convectional air-flow through ventilating holes of the
enclosure.
The load balance should be done before installation Switcha. The given value of 30 W per port is the maximum value
referring to a single output. The total power consumption should not exceed 48 W when all PoE ports are being used. The
increased demand for power is particularly evident in the case of cameras with heaters or infrared illuminators - when launching
these features, the power consumption increases rapidly, which may adversely affect the operation of the switch. The device is
designed for a continuous operation and is not equipped with a power-switch. Therefore, an appropriate overload protection in
the power supply circuit should be provided. The electrical system shall be made in accordance with applicable standards and
regulations.
2.2. Installation procedure
1. Connect switch to the PSD520115 52 V DC power supply unit desktop type.
2. Connect the power supply to the 230 V socket.
3. Connect the camera wires to the RJ45 connectors (PoE connectors).
4. Check the optical indication of the switch operation (see Table 3).
4
Connection schemes.
5
3. Operation indication.
Table 4. Operation indication
OPTICAL INDICATION OF THE SWITCH's POWER SUPPLY
GREEN LED LIGHT (Power)
Indication of the switch's
power supply
OFF no power supply of the switch
ON power supply on, normal operation
OPTICAL INDICATION AT THE PoE PORTS (1÷4)
GREEN LED LIGHT (PoE)
Indication of the PoE power
supply at the RJ45 ports
OFF- no power supply at the RJ45 port (the device is not connected or not compliant
with the IEEE802.3af/at standard)
ON supply at the RJ45 port
Blinking short-circuit or output overload
YELLOW LED LIGHT (LINK)
The connection status of LAN
devices, 10/100/1000Mb/s
and data transmission
OFF- no connection
ON - the device is connected; 10/100/1000Mb/s
Blinking data transmission
OPTICAL INDICATION AT THE UP LINK PORTS
GREEN LED LIGHT
OFF- no connection/ the device is connected 10/100 Mb/s
ON the device is connected 1000 Mb/s
YELLOW LED LIGHT (LINK)
The connection status of LAN
devices and data transmission
OFF- no connection
ON - the device is connected 10/100/1000Mb/s
Blinking data transmission
YELLOW LED LIGHT (SFP)
The connection status of LAN
devices and data transmission
OFF- no connection
ON - the device is connected
Blinking data transmission
6
WEEE LABEL
Waste electrical and electronic equipment must not be disposed of with normal household waste.
According to the European Union WEEE Directive, waste electrical and electronic equipment should
be disposed of separately from normal household waste.
Pulsar sp. j.
Siedlec 150, 32-744 Łapczyca, Poland
Tel. (+48) 14-610-19-40, Fax. (+48) 14-610-19-50
e-mail: biuro@pulsar.pl, sales@pulsar.pl
http:// www.pulsar.pl, www.zasilacze.pl
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Pulsar SFG64F1 Instrukcja obsługi

Kategoria
Routery
Typ
Instrukcja obsługi

w innych językach