AMP Lighting APL-3019-4-B-BZ Instrukcja instalacji

Typ
Instrukcja instalacji

Niniejsza instrukcja jest również odpowiednia dla

INSTALLATION & MAINTENANCE GUIDE
Help Hotline:
1-813-978-3900 • Mon-Fri 9am-6pm (EST)
www.amplighting.com
AMP
®
Low Voltage Landscape Lighting
AMP
®
PillarPro LED Post-Top Light
APL-3019-4-B-BZ
AMP
®
PillarPro LED Post-Top Light
APL-3019-4-B-BZ
INSTALLATION & MAINTENANCE GUIDE
www.amplighting.com
–2–
Important Safety Instructions: Read Before Installation
!
This luminaire is intended for installation in accordance with local codes
and the National Electric Code (NEC). Failure to adhere to these codes and
instructions may result in serious injury, property damage and void the
warranty.
These instructions do not intend to cover all variations in installation,
operation maintenance or mounting situations.
1. Make sure the power is turned OFF before installing or servicing this
luminaire.
2. WARNING: risk of electrical shock. Install all luminaires 10 feet (3.05M)
or more from pool, spa or fountain.
3. This luminaire is intended to be used only with a power supply
(transformer) rated maximum of 300 watts (25 AMPS) at 15 volts.
4. Wiring connections must be made with UL listed wire connectors that are
suitable for outdoor use.
5. Position the low voltage wire and wire connector so that it is located
within 6 inches (15.2 cm) from a building structure, a luminaire or
tting.
6. The main low voltage cable is intended for shallow burial - less than 6
inches (152 mm).
7. If additional lengths of low voltage cable are required, please contact
www.amplighting.com or call 1-813-978-3900.
Important Safety Instructions
!
INSTRUCTIONS PERTAINING TO A RISK OF FIRE, OR INJURY TO PERSONS
Lighted lamp is HOT!
WARNING – To reduce the risk of FIRE OR INJURY TO PERSONS.
1. Turn off/unplug and allow to cool before replacing lamp.
2. Lamp gets HOT quickly! Contact only switch/plug when turning on.
3. Do not touch the hot lens, guard or enclosure.
4. Keep lamp away from materials that may burn.
5. Do not touch lamp at any time. Use a soft cloth. Oil from skin may
damage lamp.
6. Do not operate the luminaire tting with a missing or damaged shield.
SAVE THESE INSTRUCTIONS
[email protected] • 813.978.3900
Optional Parts (sold separately)
–3–
Package Contents
A. (1) Fixture Body
A. (1) Stake
B. (1) Extension Riser
A. (4) Self-tapping Screws
C.
Product Dimensions
6”
7”
6”
This xture can be mounted to 4x4 wooden post or stake. Please refer
to the respective installation instruction steps per below.
INSTALLATION & MAINTENANCE GUIDE
–4–
www.amplighting.com
–4–
1
AMP
®
PillarPro LED Post-Top Light
APL-3019-4-B-BZ
Install Extension Riser on Fixture
OPTION A: MOUNT TO STAKE
2
Install Stake
Determine the desired location for
mounting the xture. Hammer the stake
into the ground until ange of stake is ush
to grade. To avoid damage to the stake,
place a board on top of the stake while
hammering.
NOTE: If the ground is hard and the stake
is difcult to install, make a crosscut in the
ground using a at shovel.
Board
Stake
Soil
Ground
Using a screwdriver, remove the
bottom 4 screws from the xture body.
Pull the lead wire into the center of
the xture through the side wire exit
and then place it through the center
hole going back out. Attach the bottom
back onto the xture body and secure
with the previously removed screws.
Thread a coupler and lock nut to
the bottom of the xture body. Then
attach the extension riser, running the
wire through all pieces.
Fixture
Body
Bottom Screw
Coupler
Lock Nut
[email protected] • 813.978.3900
–5–
INSTALLATION & MAINTENANCE GUIDE
3
AMP
®
PillarPro LED Post-Top Light
APL-3019-4-B-BZ
Install Fixture Body to Stake
Clear away an area in the ground at
the wireway slot on top of the stake.
Lay the luminaire pigtail into the
wireway slot. Then, thread the bottom
end of the extension riser with the
xture body onto the stake. Tighten to
secure the base.
Fixture Body
Base
Stake
Pigtail
Wireway Slot
Extension Riser
4
Install Fixture Body to Stake
Strip both leads from the luminaire pigtail. Using two wire connectors
(sold separately), connect the leads from the luminaire to the main
supply cable leads.
Pigtail
Main Supply Cable
Wire Connectors
INSTALLATION & MAINTENANCE GUIDE
–6–
www.amplighting.com
–6–
AMP
®
PillarPro LED Post-Top Light
APL-3019-4-B-BZ
OPTION B: MOUNT TO A 4X4 Post
1
Remove Top from Base
Using a screwdriver, unscew the screws
on the side of the base and remove the
top from the base.
Screw
Remove
To p
Base
2
Install Base to 4x4
Attach the base onto a 4” x 4” square
wood post and secure with the
self-tapping screws. Hand tighten
with a screwdriver.
Self-tapping
Screw
WOOD POST
Base
–6––6–
[email protected] • 813.978.3900
–7–
3
Install Top to Base
Screw
Install
To p
Base
Attach the top back onto the base
and secure with the screws previously
removed. Hand tighten with a
screwdriver.
4
Wire Connection
Strip both leads from the luminaire pigtail. Using two wire connectors
(sold separaetly), connect the leads from the luminaire to the main
supply cable leads.
Pigtail
Main Supply Cable
Wire Connectors
IS-APL-3019-4-B-BZ-ver1.pdf
Specications and product details subject to change without notice.
© Copyright 2019, AMP
®
Lighting, Lutz FL USA 33549 • All rights reserved.
[email protected] • 813.978.3900
Help Hotline:
1-813-978-3900 • Mon-Fri 9am-6pm (EST)
www.amplighting.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

AMP Lighting APL-3019-4-B-BZ Instrukcja instalacji

Typ
Instrukcja instalacji
Niniejsza instrukcja jest również odpowiednia dla