Grandstream GXW4500 series Instrukcja obsługi

Kategoria
Komponenty urządzeń zabezpieczających
Typ
Instrukcja obsługi
Grandstream Networks, Inc.
GXW45XX Series
Digital VoIP Gateway
Technical Bulletin - Power Consumption
P a g e | 2
GXW45XX Series Power Consumption Technical Bulletin
DOCUMENT PURPOSE
This document is a technical bulletin describing power consumption details for GXW45XX Series.
GXW45XX Digital VoIP Gateway series can be powered via Universal power supply Input: 100 ~ 240VAC,
50/60Hz; Output: DC+12V, 2A
TEST CONDITION TERMINOLOGY
The following test condition terminology was used in table 1.
1. Starting up State:
The GXW45XX has completed the boot-up process and idle.
2. Work normal State:
4x E1 ports working simultaneously, each E1 port calls 30 lines at the same time, total of 120 lines.
3. Maximum working state:
4x E1 ports working simultaneously + USB (1000mA), each E1 port calls 30 lines at the same time, total
of 120 lines.
POWER CONSUMPTION
Table 1: Power consumption
Item
Model
Power Adapter(12VDC)
Idle State
Work State
Power(W)
Power(W)
1
GXW4501
11.71
14.49
2
GXW4502
11.71
14.55
3
GXW4504
11.71
15.81
  • Page 1 1