AMP Lighting ASL-6010-B-BZ Instrukcja instalacji

Typ
Instrukcja instalacji

Ten podręcznik jest również odpowiedni dla

INSTALLATION & MAINTENANCE GUIDE
Help Hotline:
1-813-978-3900 • Mon-Fri 9am-6pm (EST)
www.amplighting.com
AMP
®
Low Voltage Landscape Lighting
AMP
®
InfusePro Step Light
ASL-601X-4-B-BZ
AMP
®
InfusePro Step Light
ASL-601X-4-B-BZ
INSTALLATION & MAINTENANCE GUIDE
www.amplighting.com
–2–
Important Safety Instructions: Read Before Installation
!
This luminaire is intended for installation in accordance with local codes
and the National Electric Code (NEC). Failure to adhere to these codes and
instructions may result in serious injury, property damage and void the
warranty.
These instructions do not intend to cover all variations in installation,
operation maintenance or mounting situations.
1. Make sure the power is turned OFF before installing or servicing this
luminaire.
2. WARNING: risk of electrical shock. Install all luminaires 10 feet (3.05M)
or more from pool, spa or fountain.
3. This luminaire is intended to be used only with a power supply
(transformer) rated maximum of 300 watts (25 AMPS) at 15 volts.
4. Wiring connections must be made with UL listed wire connectors that are
suitable for outdoor use.
5. Position the low voltage wire and wire connector so that it is located
within 6 inches (15.2 cm) from a building structure, a luminaire or
tting.
6. The main low voltage cable is intended for shallow burial - less than 6
inches (152 mm).
7. If additional lengths of low voltage cable are required, please contact
www.amplighting.com or call 1-813-978-3900.
Important Safety Instructions
!
INSTRUCTIONS PERTAINING TO A RISK OF FIRE, OR INJURY TO PERSONS
Lighted lamp is HOT!
WARNING – To reduce the risk of FIRE OR INJURY TO PERSONS.
1. Turn off/unplug and allow to cool before replacing lamp.
2. Lamp gets HOT quickly! Contact only switch/plug when turning on.
3. Do not touch the hot lens, guard or enclosure.
4. Keep lamp away from materials that may burn.
5. Do not touch lamp at any time. Use a soft cloth. Oil from skin may dam-
age lamp.
6. Do not operate the luminaire tting with a missing or damaged shield.
SAVE THESE INSTRUCTIONS
[email protected] • 813.978.3900
Product Dimensions
–3–
Cut Hole
1
Package Contents
A. (1) Housing
B. (1) Luminaire Cover with
Gasket
C. (2) Lock Screws
Before Starting:
1. Desired location for each luminaire should be determined before
construction of the wall is started.
2. If access to the back of the wall is limited, the cable/conduit should
be run prior to construction.
Open Face Step Light Hooded Step Light Louvered Step Light
8.25”
7”
2.75”
3.25”
3”
3.5”
Using the luminaire housing as a
template, mark the location of the
housing on the wall or deck. Cut
the hole from the mark.
Housing
Hole
Installation in Wall or Stair, Refer to Step 1 to Step 2.
INSTALLATION & MAINTENANCE GUIDE
–4–
www.amplighting.com
–4–
Install Bulb
4
Install Housing in Wall or Deck
2
AMP
®
InfusePro Step Light
ASL-601X-4-B-BZ
Install Housing in Brick Wall
3
Pass the supply wires through the
cut holes and insert the housing
into the hole. Secure with screws.
Continue from Step 4 to complete
all installations.
Housing
Hole
Screw
Main Low Voltage
Supply Cable
Installation in Brick Wall, Refer to Step 3.
Mortar housing into place as if it
were a brick.
Continue the following steps to
complete all installations.
Housing
Brick
Main Low Voltage
Supply Cable
Insert the bulb with the correct
wattage and type marked on the
luminaire label.
CAUTION: Do not exceed maximum
wattage marked on luminaire label.
NOTE: DO NOT touch bulb with bare
hands. Use soft cloth to handle lamp.
Bulb
Socket
[email protected] • 813.978.3900
INSTALLATION & MAINTENANCE GUIDE
AMP
®
InfusePro Step Light
ASL-601X-4-B-BZ
Install/Replace Bulb
Install Fixture Faceplate with Gasket
5
Place the luminaire faceplate with
gasket onto housing and secure with
lock screws.
Lock Screw
Fixture Faceplate
with Gasket
Housing
Wire Connection
6
Strip both leads from the luminaire
pigtail. Using two wire connectors
(sold separately), connect the
leads from the luminaire to the
main supply cable leads.
Wire Connectors
Pigtail
Luminaire
Main Low Voltage
Supply Cable
Reverse Step 4 - Step 5 to expose the bulb and replace it with the correct
wattage and type marked on the luminaire label. Reinstall the luminaire
cover.
IMPORTANT: Halogen lamps must be protected from moisture and dust at all
times. Always reinstall luminaire cover when moved.
–6–
www.amplighting.com
–6–
–6––6–
[email protected] • 813.978.3900
–7–
IS-ASL-601X-$-B-BZ.pdf
Specications and product details subject to change without notice.
© Copyright 2019, AMP
®
Lighting, Lutz FL USA 33549 • All rights reserved.
[email protected] • 813.978.3900
Help Hotline:
1-813-978-3900 • Mon-Fri 9am-6pm (EST)
www.amplighting.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

AMP Lighting ASL-6010-B-BZ Instrukcja instalacji

Typ
Instrukcja instalacji
Ten podręcznik jest również odpowiedni dla

w innych językach