Product Description
TC-5
The TesiraCONNECT is an AVB-capable PoE+ five-port room expansion device
designed to connect Biamp AVB equipment in small conference systems.
Four ports provide PoE+ with no power budget restrictions. The
TesiraCONNECT eliminates the need for third-party switches and provides
power and media streaming to each Biamp device via category cable.
Setup and Use
The TesiraCONNECT is designed to work out of the box without any user
configuration required, but Tesira software provides an intuitive interface for
features such as locate and firmware updates. The information supplied by this
manual relates to physical connections and device setup. For more details on
software, please consult the Tesira Help File.
Up to four TesiraCONNECT devices may be connected in daisy chain or star
topology to support additional Tesira devices or remote mounting locations.
Installation
Install away from heat sources, such as vents, radiators, heat registers and
stoves. Also avoid installing near water or steam. Do not exceed the maximum
ambient operating temperature of 32-104° F (0-40° C). Be aware of conditions
in an enclosed rack that may cause the temperature to exceed ambient room
conditions.
TesiraCONNECT may be installed in various locations and an optional
mounting bracket (ordered separately) allows the TesiraCONNECT to be
securely fastened under tables, on walls, etc.
Features
5 AVB-capable RJ-45 ports
Provides 4-ports of PoE+ Class 4 with 120W total power (ports 2-5)
100/1GB port speed over 5 RJ-45 ports
LED status indicators
External universal power supply
Requires CAT5e cabling or better
All ports provide AVB media streaming, daisy chaining and RSTP support.
Includes power supply
TesiraCONNECT TC-5
Installation & Operation Guide
MAY 2020
A: 9300 S.W. Gemini Drive Beaverton, OR 97008 USA W: www.biamp.com
Product Installation
TesiraCONNECT may be installed in almost any location that is convenient
for room design, requirements, etc. Be sure to allow for adequate airflow over
the ventilation grilles.
On a rack shelf
In a plenum/air-handling space
In a cabinet/credenza
Optional Mounting Bracket Kit
An optional mounting bracket may be ordered separately which allows
greater flexibility in mounting options, such as directly under a table, on a
wall, behind a display or any other flat surface that requires secure mounting.
The mounting bracket kit contains the following:
A) Mounting Bracket
B) Screw (x4)
C) Lock Washer (x4)
D) Washer (x4)
E) Screw (x4)
F) Zip Ties (x25)
1. Determine the location where the TesiraCONNECT is to be located.
2. Install the bracket onto the TesiraCONNECT with hardware as shown in
Figure 1.
3. Install the bracket and attached TesiraCONNECT at the desired location
with the hardware provided as shown in Figure 2.
4. Use the included zip ties to secure the power supply and cables as
required (not shown).
Figure 1 - Mounting Bracket Installation
Figure 2 - TesiraCONNECT Installation
E
D
A
C
B
A
MAY 2020
A: 9300 S.W. Gemini Drive Beaverton, OR 97008 USA W: www.biamp.com
Front Panel LEDs
There are eight multi-color LEDs on the front panel of the TesiraCONNECT
which give various information to a user.
1. Power
Status LED Indicator
No Power Off
Device is powered Green Solid
Device is in Locate mode (triggered from the software) Green Flashing
Device is booting Yellow Solid
2. Status
Status LED Indicator
No Power Off
Device is fully booted/ready Green Solid
Device is in Locate mode (triggered from the software) Green Flashing
Device is booting Yellow Solid
3. Alarm
Status LED Indicator
No Alarm Condition Present Off
Device is in Locate mode (triggered from the software) Green Flashing
Unit has a major alarm present Red Solid
Unit has a minor alarm present Yellow Solid
Unit has a major and minor alarm present Alternating Red/Yellow
4. RJ45 Port Status Indicators
Status LED Indicator
No Alarm Condition Present Off
Ethernet link is active Green Solid
Device is in Locate mode (triggered from the software) Green Flashing
1. Power Indicator
2. Device Status
3. Alarm Status
4. RJ45 AVB Port Status
5. RJ45 AVB Port (non-PoE+)
6. RJ45 AVB Ports (PoE+)
7. Power Connection
Front Panel Rear Panel
MAY 2020
A: 9300 S.W. Gemini Drive Beaverton, OR 97008 USA W: www.biamp.com
Four TesiraCONNECT Devices in Daisy Chain
Tesira Server Device
TesiraCONNECT
Connect up to 13 Tesira AVB Devices
TesiraCONNECT Wiring Topology Examples
Control/Monitoring
MAY 2020
A: 9300 S.W. Gemini Drive Beaverton, OR 97008 USA W: www.biamp.com
Four TesiraCONNECT Devices in Star Chain
Connect up to 13 Tesira
AVB Devices
TesiraCONNECT
TesiraCONNECT Wiring Topology Examples
Tesira Server Device
Control/Monitoring
MAY 2020
A: 9300 S.W. Gemini Drive Beaverton, OR 97008 USA W: www.biamp.com
One TesiraCONNECT - Single Conference Room System
TesiraCONNECT Wiring Topology Examples
Tesira Server Device
TesiraCONNECT
EX-UBT
HD-1
TCM-XA with Parle Mics
desono C-IC6 Loudspeakers
Control/Monitoring
4 Speakers in Daisy Chain
MAY 2020
A: 9300 S.W. Gemini Drive Beaverton, OR 97008 USA W: www.biamp.com
Two TesiraCONNECTs in Daisy Chain - Divisible/Combinable Room Space
Tesira Server Device
TesiraCONNECT
TesiraCONNECT
EX-UBT
HD-1
4 Speakers in Daisy Chain
TesiraCONNECT Wiring Topology Examples
TCM-XA with Parle Mics
EX-UBT
TCM-XA with Parle Mics
TCM-XA with Parle Mics
TCM-XA with Parle Mics
Control/Monitoring
MAY 2020
A: 9300 S.W. Gemini Drive Beaverton, OR 97008 USA W: www.biamp.com
One TesiraCONNECT Device Connected to Two Systems (Two Rooms Sharing one TesiraCONNECT)
Tesira Server Device
TesiraCONNECT
Tesira Server Device
TCM-XA with 2 Parle Mics and
4 Speakers in Daisy Chain
TesiraCONNECT Wiring Topology Examples
Control/Monitoring
Control/Monitoring
TCM-XA with 2 Parle Mics and
4 Speakers in Daisy Chain
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Biamp TesiraCONNECT TC-5 Installation & Operation Guide

Kategoria
Przełączniki szeregowe
Typ
Installation & Operation Guide

w innych językach