Aero Pure AP90H-SL SN Specyfikacja

Typ
Specyfikacja

Niniejsza instrukcja jest również odpowiednia dla

Model: AP90-SL Series
4” Duct
Static Pressure (inches w.g.)
0.1
0.25
Air Volume (CFM)
90
73
Noise (sones)
0.3
n/a
Power Consumption (Watts)
33
32.3
Energy Efficiency (CFM/Watts)
2.7
2. 2
Current (AMPS)
0.4
0.36
Grille Dimensions
13 3/8’ x 13 3/8”
Model
Qty
Comments
Specifications
AP 90-SL SERIES
Slim Fit Bathroom Fan with 10W 3000K LED Light
ETL Listed for installation over tub/shower enclosure with
GFCI circuit wiring.
Description: Quiet slim fit bathroom fan with 10W 3000K 850
Lumens LED light Engineered for continuous run Ceiling or
wall mount Suitable for new construction or remodeling HVI
certified ETL listed for use in insulated ceilings (Type I.C.).
Motor/Blower: Permanently lubricated enclosed condenser
motor engineered for continuous energy efficient operation;
power rating 120v/60Hz; motor equipped with thermal shut off.
Housing: Rugged 26 GA galvanized steel; detachable 4 and 6
duct connector with built-in back draft dampener; 2 anti-vibration
hangar bar brackets adjustable to 24” span included; designed for
ceilings with a minimum of 6” clearance.
Grille: Contemporary design; low maintenance, wipe clean UV
inhibiting polymeric resin; attaches to housing with torsion
springs.
Finishes: White (W); Satin Nickel (SN); Oil Rubbed Bronze
(OR).
Light: 10W 3000K 850 Lumens LED light
Installation: Must be installed by a licensed professional.
Complete installation instructions included.
Warranty: 6 Years
Architects Specifications: Ventilation fan will be ceiling or wall
mount and no more than 0.3 sones at 90 CFM as certified by HVI
at 0.1 Ps (inches water gauge). Power consumption shall be no
greater than 33 watts with an efficiency rating of no less than 2.7
CFM/watt. Light shall be 10W 3000K LED light. The motor will
be permanently lubricated, engineered for continuous operation.
Duct diameter will be 4 or 6” round. Fan shall be ETL/cETL
listed for tub/shower enclosure when used with GFCI branch
circuit wiring and shall be ETL/cETL listed for use in insulated
ceiling (Type I.C.).
Aero Pure, LLC 1006 Bankton Circle Ste B Hanahan, SC 29410 843.377.8642
www.ae ropurefans .c o m
Model: APH90-SL Series
4” Duct
Static Pressure (inches w.g.)
0.1
0.25
Air Volume (CFM)
90
73
Noise (sones)
0.3
n/a
Power Consumption (Watts)
33
32.3
Energy Efficiency (CFM/Watts)
2.7
2. 2
Current (AMPS)
0.4
0.36
Grille Dimensions
13 3/8’ x 13 3/8”
Model
Qty
Comments
Specifications
AP 90H-SL SERIES
Slim Fit Bathroom Fan with 10W 3000K LED Light
and Integrated Humidity Sensor
ETL Listed for installation over tub/shower enclosure with
GFCI circuit wiring.
Description: Slim fit bathroom fan with 10W 3000K 850
Lumens LED light Engineered for continuous run Integrated
user adjustable humidity sensor Ceiling or wall mount Suitable
for new construction or remodeling HVI certified ETL listed
for use in insulated ceilings (Type I.C.).
Motor/Blower: Permanently lubricated enclosed condenser
motor engineered for continuous energy efficient operation;
power rating 120v/60Hz; motor equipped with thermal shut off.
Housing: Rugged 26 GA galvanized steel; detachable 4 and 6”
duct connector with built-in back draft dampener; 2 anti-vibration
hangar bar brackets adjustable to 24” span included; designed for
ceilings with a minimum of 6” clearance.
Grille: Contemporary design; low maintenance, wipe clean UV
inhibiting polymeric resin; attaches to housing with torsion
springs.
Finishes: White (W); Satin Nickel (SN); Oil Rubbed Bronze
(OR).
Light: 10W 3000K 1100 Lumens LED light
Installation: Must be installed by a licensed professional.
Complete installation instructions included.
Warranty: 6 Years
Architects Specifications: Ventilation fan will be ceiling or wall
mount and no more than 0.3 sones at 90 CFM as certified by HVI
at 0.1 Ps (inches water gauge). Power consumption shall be no
greater than 33 watts with an efficiency rating of no less than 2.7
CFM/watt. Light shall be 10W 3000K LED light. Fan will begin
operation when humidity rises above user adjustable setpoint (50-
100% RH). The motor will be permanently lubricated, engineered
for continuous operation. Duct diameter will be 4” or 6” round.
Fan shall be ETL/cETL listed for tub/shower enclosure when
used with GFCI branch circuit wiring and shall be ETL/cETL
listed for use in insulated ceiling (Type I.C.).
Aero Pure, LLC 1006 Bankton Circle Ste B Hanahan, SC 29410 843.377.8642
www.ae ropurefans .c o m