This thermostat can be used with all millivolt and 24VAC heating and cooling systems. It
cannot be used with line voltage systems. This thermostat is digital and your desired heat or
cool temperatures can be easily be set on the large touch screen with
the UP/DOWN arrows. A minimum 4 minute off time protects heating
and cooling systems from damage.
This thermostat uses a new technique called sequential staging for
more comfort with faster reaction to requested temperature changes.
When using a heat pump with Auxiliary heat, if the heat pump
cannot keep up and/or is defective, touch the MENU button, then
touch PUMP; the PUMP OFF icon will come on.. The aux heat will
then be your only source of heat. When the heat pump is again
operational, be sure to turn the heat pump back on by touching
MENU and then PUMP (off icon goes out) as the aux heat is more
expensive than pump heat.
6035 Features
Wire Reference
Your Wires Ritetemp Terminal
R or V or VR RH and RC Single power for HEAT and COOL
RH or 4 RH Power for HEAT (RH not connected to RC)
RC RC Power for COOL (RH not connected to RC)
W W Heat control
W2 W2 2nd stage HEAT or heat pump auxiliary heat
? A 3rd wire for zoned hot water heat (see zoned)
Y Y COOL control
Y2 Y2 2nd stage COOL control
G or F G FAN control
C or X C Common 24VAC power (to power thermostat)
E Emergency heat (do not connect, tape off)
L System monitor (do not connect, tape off)
T Outdoor sensor (do not connect, tape off)
B or B Heat pump changeover (cool to heat, powered in heat)
O O Heat pump changeover (heat to cool, powered in cool)
B and O SEE NOTE
PG 23
PG 24
B and O
NOTE: If
there are both
B and O wires
(Trane pump
products)
DO NOT
CONNECT B
to B terminal,
connect B to C
terminal
MENU
PROG
PM
AUTO
ON
COOL
OFF
HEAT
FAN