Tissot Dressport Instrukcja obsługi

Kategoria
Zegarki
Typ
Instrukcja obsługi

Niniejsza instrukcja jest również odpowiednia dla

*
www.tissot.ch
144_EN / 12.09
1/4
Chronographs G15
User's Manual
Standard model
Hour hand
Minute hand
Seconds hand
Date indicator
Standard chronograph:
60-second counter hand
30-minute counter
1/10 second counter
Retrograde model
Hour hand
Minute hand
Seconds hand
Date indicator
Retrograde chronograph:
30-second retrograde counter hand
60-minute counter
5-minute retrograde counter
* Models with a screwed down crown:
IA Initial position (screwed down, not pulled out)
IB Neutral position (unscrewed, not pulled out)
Crown with 3 positions (8) :
I
Neutral position (screwed down*, not pulled out)
II
Setting position for date (unscrewed*, half pulled out)
III
Setting position for time (unscrewed*, completely pulled out)
Chronographs G15
*
www.tissot.ch
144_EN / 12.092/4
Settings
Models with a screwed down crown
To ensure even better water-resistance, some models are fitted with a screwed down crown. Before setting the time or date, you must first unscrew the crown to position
IB
, before pulling it out to position
II
or
III.
Important : After each operation, you must always screw the crown back down to ensure that your watch remains water-resistant.
Setting the time
Pull the crown out to position
III
and turn it clockwise or anticlockwise to set the desired time. Synchronise the small seconds hand at the 6 o'clock position with an
official time signal (radio/ TV/Internet) by pulling out the crown to the second notch; the hand will then stop. Once the time has been synchronised, push the crown
back down into position I (and tighten it back down on models with a screwed down crown).
Winding
Quartz watches never need to be wound.
Rapid date correction
Pull the crown out to position
II
and turn it anticlockwise until the correct date is displayed.
Speedometer (depending on the model)
The speedometer is used to measure the speed of an object which is moving at a constant speed. Start the timing operation and stop it again once you have covered
a distance of 1 km. The chronograph hand then points at a numeral on the tachometric scale, indicating the speed in km/h.
Acknowledgements
Thank you for choosing a chronograph from TISSOT
®
, one of the most highly renowned Swiss brands in the world. Meticulously assembled using high quality
materials and components, it is protected against impacts, temperature variations, water and dust.
This manual applies to TISSOT
®
standard and retrograde quartz chronographs with G15 movement. For the settings and operation of your chronograph, please refer
to the instructions corresponding to your model.
Your chronograph allows you to time events lasting up to 30 or 60* minutes, and offers you the following functions:
– Standard chronograph START–STOP function
– ADD function (partial times)
– SPLIT function (intermediate times)
To ensure that your chronograph operates with perfect precision for many years to come, we advise you to pay careful attention to the advice given in this
manual.
*Retrograde model
Resetting the counters (standard model)
The counters must be reset before starting timing. If necessary, proceed as follows:
Reset the 30-minute counter hand:
- Crown in position
II
, push-piece
B
Reset the 60-second counter hand:
- Crown in position
III
, push-piece
A
Reset the 1/10 second counter hand:
- Crown in position
III
, push-piece
B
Resetting the counters (retrograde model)
The counters must be reset before starting timing. If necessary, proceed as follows:
1
Reset the 60-minute counter hand:
- Crown in position
II
, push-piece
B
2
Reset the 30-second retrograde counter hand:
- Crown in position
III
, push-piece
A
3
Reset the 5-minute retrograde counter hand:
- Crown in position
III
, push-piece
B
20
Chronographs G15
*
www.tissot.ch
144_EN / 12.093/4
Simple timing
The "simple timing" function enables you to measure isolated events.
1
START
2
STOP
Time readout (as per example above)
- 5 minutes,
- 57 seconds,
- 7/10ths of a second
3
Reset
NB:
Before each timing operation, the chronograph hands must be at their start points. If necessary, refer to
the
RESETTING THE COUNTERS paragraph.
Notes : All the timing functions are available with the crown pressed into position I.
On the Retrograde model, the "simple timing" function is no different from that on a standard chronograph, but
the retrograde counter hand turns anticlockwise, from 9 o' clock to 3 o'clock.
ADD function
The ADD function enables you to measure consecutive events without having to reset in between. Each time
is added to the previous total.
1
START
2
STOP
Readout
3
RESTART
4
STOP
Readout
5
RESTART
6
STOP
Readout
X
Reset counters
SPLIT-TIME function
The SPLIT-TIME function enables you to stop the hands to read an intermediate time, without interrupting
timing. When you restart, the chronograph hands "catch up" to the ongoing elapsed time.
1
START
2
SPLIT 1
Time 1 readout (as per fig. 2)
- 5 minutes,
- 4 seconds,
- 6/10ths of a second
3
RESTART (catchup)
4
SPLIT 2
Time 2 readout
- 15 minutes,
- 36 seconds,
- 8/10ths of a second
5
RESTART (catchup)
6
STOP
Final time readout (cumulative time)
- 25 minutes,
- 18 seconds,
- 4/10ths of a second
7
Reset counters
Chronographs G15
*
www.tissot.ch
144_EN / 12.094/4
Care and maintenance
We would advise you to clean your chronograph regularly (except for the leather strap) using a soft cloth and lukewarm soapy water. After immersion in salt water,
rinse it in fresh water and leave it to dry completely.
Do not leave it anywhere subjected to high variations in temperature or humidity, direct sunlight or strong magnetic fields.
We would advise you to have your watch inspected every 3 to 4 years by an approved TISSOT
®
representative or retailer. To enjoy impeccable maintenance service
and ensure the guarantee remains valid, always consult an authorised TISSOT
®
representative or retailer.
TISSOT
®
quartz chronographs have the incomparable precision of quartz. Their power reserve is usually more than 2 years in continuous use. If you plan not to
wear your chronograph for several weeks or months, we would advise you to store it with the crown pulled out to position
III.
This cuts the electrical power supply
to the motor, thereby extending battery life considerably.
Replacing the battery
Once the battery has been drained, it must be replaced without delay by an approved TISSOT
®
representative or retailer.
Battery type: button-type zinc-silver oxide primary battery cell, 1.55 V Battery, No. 394, SR 936 SW.
Collection and treatment of end of life quartz watches*
This symbol indicates that this product should not be disposed with household waste. It has to be returned to a local authorized collection system. By
following this procedure you will contribute to the protection of the environment and human health. The recycling of the materials will help to conserve
natural resources.
* valid in the EU member states and in any countries with corresponding legislation.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Tissot Dressport Instrukcja obsługi

Kategoria
Zegarki
Typ
Instrukcja obsługi
Niniejsza instrukcja jest również odpowiednia dla

w innych językach