Danfoss 3060 Installation & User's Instructions

Typ
Installation & User's Instructions
3060
Installation & User Instructions
electro-mechanical
programmer for controlling
heating & hot water
This product complies with the following EC Directives:
Electro-Magnetic Compatibility Directive.
(EMC) (2004/108/EC)
Low Voltage Directive.
(LVD) (2006/95/EC)
2
INDEX
Index
Installation
Productspecication 3
Installation 4
Wiring 4-5
User
Yourprogrammer 6
Programmingtheunit 6-7
Settingtheclock 7
Usingtheprogrammer 8-9
Contactdetails 12
3
Please Note:
This product should only be installed by a qualied
electrician or competent heating installer, and
should be in accordance with the current edition of
the IEEE wiring regulations.
Specication
Power supply 230±15%Vac,50/60Hz
Switchaction 2xSPST,type1B
Switchrating
Max264Vac,50/60Hz,3(1)A
Timingaccuracy ±1min/month
Enclosurerating IP30
Max.ambienttemperature 55°C
Dimensions,mm(W,H,D) 102 x 210 x 60
Designstandard EN60730-2-7
Construction Class1
ControlPollutionSituation Degree 2
RatedImpulseVoltage 2.5kV
BallPressureTest 75°C
Product specication
Installation Instructions
Specication
4
3060
Installation
Installation
1. Removelowersettingdial.Setallfourtappetstotop
ofupperdial.Unscrew4BAscrewandremoveouter
case.
2. Slackentwoscrewssecuringplug-inmoduleto
backplateandseparatemodulefrombackplateby
pullingupwards.
3. Fixbackplatetowall(3holexing).
4. Referringtowiringdiagramsbelowandopposite
makeelectricalconnectionsasshown(asapplicable).
Thediagramsindicatethatterminals3and5arenot
internallyconnectedtotheprogrammerandmay
thereforebeusedassparewiringterminalsifrequired.
5. Easeofinstallationcanbeachievedbytheuseofthe
DanfossRandallWiringCentrewhichisobtainable
frommostBuildersMerchantsandDistributors.
NOTE: If a Wiring Centre is used follow the
installation instructions included with that unit and
not the following wiring diagrams.
6. Securecablecoresundercableclamp.
5
Wiring
Wiring
12345678910
S/L
LN
Brown
Orange
Grey
Blue
Danfoss Randall
HP22 or HP28
SRZV (Hot Water)
Brown
Orange
Grey
Blue
Danfoss Randall
HP22 or HP28
SRZV (Heating)
Flying lead
Flying
lead
2
4
1
(N)
12
3
4
5
6
7
Danfoss Randall
ATC Cylinder Stat
2
3
1
3 core
2 core3 core
Danfoss
Randall
RMT230
Room Stat
3060
Te rminals
Mains
Supply
N
L
2 core +
3 or 4 core
N
N
L
L
Boiler
Pump
Permanent line
supply for boiler
if required
12
3
4
5
6
7
2
4
1
N
L
Boiler
1
2
3
Danfoss Randall
ATC Cylinder Stat
Danfoss
Randall
RMT230
Room
Stat
N
L
Pump
3060
Te rminals
Mains
Supply
N
L
WIRING - FULLY PUMPED SYSTEM
WIRING - GRAVITY HOT WATER SYSTEM
NOTE: This unit is NOT suitable for use with fully motorised zone valves
requiring both ON and OFF electrical signals when used in the heating
circuit
12345678910
S/L
LN
Brown
Orange
Grey
Blue
Danfoss Randall
HP22 or HP28
SRZV (Hot Water)
Brown
Orange
Grey
Blue
Danfoss Randall
HP22 or HP28
SRZV (Heating)
Flying lead
Flying
lead
2
4
1
(N)
12
3
4
5
6
7
Danfoss Randall
ATC Cylinder Stat
2
3
1
3 core
2 core3 core
Danfoss
Randall
RMT230
Room Stat
3060
Te rminals
Mains
Supply
N
L
2 core +
3 or 4 core
N
N
L
L
Boiler
Pump
Permanent line
supply for boiler
if required
12
3
4
5
6
7
2
4
1
N
L
Boiler
1
2
3
Danfoss Randall
ATC Cylinder Stat
Danfoss
Randall
RMT230
Room
Stat
N
L
Pump
3060
Te rminals
Mains
Supply
N
L
WIRING - FULLY PUMPED SYSTEM
WIRING - GRAVITY HOT WATER SYSTEM
NOTE: This unit is NOT suitable for use with fully motorised zone valves
requiring both ON and OFF electrical signals when used in the heating
circuit
6
User Instructions
Your programmer
The3060programmerallowsyoutoswitchyourhotwater
andheatingonandoffattimesthatsuityou.
Fourtappetsonthetimingdialletyoudecidewhenyou
wantyourhotwaterandheatingtocomeonandgooff
eachday.Theprogrammerprovides2ONtimesand2
OFFtimesperday.
Usingthelowerdialyoucanchoosehowyoucontrolyour
HeatingandHotWater,eitheratthesettimes,constantly
ON,constantlyOFF(eachindifferentcombinations).
Duringthesummerthecentralheatingcanbeturnedoff,
whilststillcontrollingthehotwateratthesettimes.
Your Programmer & Programming the unit
Programming the unit
TherearefourTAPPETSonyourtimingdial,tworedand
twoblue:
o the redtappetsaretheON switches
o the bluetappetsaretheOFF switches
1. Holdthecentralblack&
silverknobwithonehand
andmovetheredtappet
marked‘Aclockwise to
thetimeyouwantyour
HEATING/HOTWATERto
switch oninthemorning.
NB.youmayndthetappetsquitestiff,soyoumay
havetopushthemquitermlytomovethem.
7
Setting the clock
2 Stillholdingthecentralknob,movethebluetappet
marked‘B’tothetimeyouwantyourHEATING/HOT
WATERtoswitchoffinthemorning.
3 Youcansetyourothertwotappetsinthesameway
tosetyourHEATING/HOTWATERfortheafternoon
orevening.
EXAMPLE
(NB.Clockisin24hourmode)
IfyouwantyourheatingandhotwaterONbetween
7amand10amandONagainbetween5pmand
11pm,settappetsasfollows:
Aat1stONtime=7
Bat1stOFFtime=10
Cat2ndONtime=17
Dat2ndOFFtime=23
Setting the Clock
o Turnthedialclockwise
until the correct time is
lined up with the dot
labelledTIME
NB.clockisin24hour
mode
REMEMBER
You will have to reset the time after a power
cut and also when the clocks change in
Spring and Autumn
!
8
Using the Programmer
Theselectorswitchisusedtoselecthowthe3060controls
yourhotwaterandheating.Theheatingandhotwatercanbe
operatedtogetherinvariouscombinations,orthewatercan
becontrolledonitsown(i.e.duringthesummerwhenonly
hotwaterisrequired).
Therearesixpositionsintowhichtheselectorswitchmay
beset.
1 - H OFF / W OFF
BothHeatingandHotWaterwillremainOFFuntilyou
changethesetting.
2 - H TWICE / W TWICE
InthispositiontheHeatingandHotWaterwillboth
comeonandgooffaccordingtothetimesyouhave
programmed(ONatA,OFFatB,ONatC,OFFatD).
3-H ONCE / W ONCE
ThissettingoverridestappetsBandC,soboth
HeatingandHotWaterwillswitchONatthetime
markedbytappetAandwillstayonuntilthetime
markedbytappetD.Bothserviceswillthenswitch
OFFuntil‘Athenextday.
Using the programmer
H+W
ON
H+W
OFF
H - TWICE
W - ONCE
H - ONCE
W - ONCE
H - TWICE
W - TWICE
H - OFF
W - TWICE
9
Using the programmer
4 - H ON / W ON
Thisisthe‘CONSTANT’positionandtheprogrammer
willremainpermanentlyONforbothHeatingandHot
Water,irrespectiveofthepositionofthetappets.
5 - H TWICE / W ONCE
Inthispositiontheheatingwillcomeonandgooff
accordingtothetimesyouhaveprogrammed(ONat
A,OFFatB,ONatC,OFFatD).
TheHotWaterwillcomeonatAandstayonuntilD.
6 - H OFF / W TWICE
InthispositiontheHeatingwillbepermanentlyOFF
andtheHotWaterwillcomeonandgooffaccordingto
thetimesyouhaveprogrammed(ONatA,OFFatB,
ONatC,OFFatD).
Note:
If hot water is required all day with the heating shut
off (i.e. heat off, water once)
o Turntheselectorswitchto‘Htwice/Wonce’and
turndowntheroomthermostattoitslowest
setting.
If constant hot water is required with heating off (i.e.
heat off, water on)
o Turntheselectorswitchto‘Hon/Won’andturn
theroomthermostattoitslowestsetting.
10
11
Danfoss Ltd
AmpthillRoad
Bedford
MK42 9ER
Tel:01234364621
Fax:01234219705
Still having problems?
Callyourlocalheatingengineer:
Name:
Tel:
Visitourwebsite:
www.heating.danfoss.co.uk
Emailourtechnicaldepartment:
Callourtechnicaldepartment
0845 121 7505
(8.45-5.00Mon-Thurs,8.45-4.30Fri)
For a large print version of these
instructions please contact the Marketing
Services Department on 0845 121 7400.
PartNo.7485v0306/08
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Danfoss 3060 Installation & User's Instructions

Typ
Installation & User's Instructions

w innych językach